New Installation - Mira JUMP Installation And User Manual

Electric shower
Hide thumbs Also See for JUMP:
Table of Contents

Advertisement

6.
Position the Mira Jump shower on the
existing pipework. Adjust the shower
inlet for water supply pipe position if
required. Do not connect shower to
pipe.
7.
The case has thinned sections that
can be removed to allow entry of the
electrical cables. Remove either of the
top thinned sections of the case for a
falling supply.
8.
Feed the electrical cable in through
the back of the shower and make sure
the wires will connect adequately to
one of the terminal blocks.
9.
Make sure the shower is straight and
level, then mark the new fixing holes
on the wall.
10. Remove the shower and drill the new
fixing holes. Insert the supplied wall
plugs.
Caution! Do not drill into buried pipes
or cables.
Go to "Connecting Electricity and
Water Supplies" to complete the
installation

New Installation

1.
Determine the approximate position
of the shower according to the
dimensions specified in the diagram
(Fig 1.1).
2.
Place the installation template on the
wall and mark the positions of the
fixing holes. Make sure that there
are sufficient lengths of supply pipe
and electrical cable to reach the
connection points as shown on the
template.
BELOW
Alternative
Fixing Hole
Important! Prior to product installation this installation template must be used in conjunction with
the Installation and User Guide (IUG) to make sure that key installation and operation actions are
followed.
Minimum maintained inlet pressure:
Maximum static inlet pressure 1000kPa (10 bar).
Do not install the appliance in a position where it may become frozen.
The appliance must be earthed by connecting the supply cable earth conductor to the
appliance earth terminal.
Live &
A 30mA Residual Current Device (RCD)
Neutral
may be part of the consumer unit or a separate unit.
Terminal
When mounting the appliance to the wall make sure that a sufficient length of electrical
supply cable is available to connect to the appliance terminal block.
Block
Earth
Terminal
Block
1131494-W7-B (1693) (J96Va/Wa/Xa)
15
REAR
SIDE
INSTALLATION TEMPLATE
Allow at least 170mm
above the appliance to
Alternative
Fixing Hole
access cover screws.
Fixing Hole
S e e
I n s t a l l a t i o n
& U s e r G u i d e f o r
further dimensions
especially for a shower
replacement.
Use spirit level to make
Attention Installer!
sure template is level
before drilling
Live &
70kPa (0.7 bar) for 8.5kW & 9.5kW, 100kPa (1.0 bar) for 10.8kW.
Neutral
Terminal
Block
MUST be included in the electrical circuit. This
Do not take risks with wiring. As with all high performance
instantaneous electric showers it is very important that the
correct size of supply cable is used to prevent cable damage
(refer to BS 7671).
Fixing Hole
Make sure that the appliance is fitted onto a finished, FLAT
wall surface i.e. on top of tiles. Caution! [Do not seal around
the back case of the appliance. Small pillars moulded onto
rear of the case allow air circulation, preventing heat and
condensation build up within the shower].
Earth
Allow at least 170mm above the appliance to access cover
Terminal
screws.
Block
Supply pipework must be flushed
thoroughly before connecting to the
appliance to prevent filter blockage
For commissioning:
Refer to the Installation and User Guide
For technical support and general
enquiries, spare parts and after
sales service contact us on:
Tel:
0844 571 5000
Fax:
01242 282 595
e-mail: technical@mirashowers.com
For Compression
Elbow Fitting
Outlet Connector
Fixing
28mm
Hole
75mm
© Kohler Mira Limited, February 2010