Mira JUMP Installation And User Manual page 17

Electric shower
Hide thumbs Also See for JUMP:
Table of Contents

Advertisement

5.
Strip a short section of the electrical
cables if required. Fit an earth sleeve
to the earth wire if required.
Caution! Make sure the bare wire
ends are completely dry before
connecting to the terminal block.
6.
Loosen the screws in the terminal
block and insert the bare wires into
the clamps:
L (Live) = Brown Wire
(Earth) = Green Sleeved Wire
N (Neutral) = Blue Wire
Note! Do not twist the cores of the
wires or strain the cables to make
them reach the terminal block.
7.
Tighten the screws in the terminal
block so that they securely clamp the
bare wires.
8.
If necessary, fit an earth bonding
clamp to the supply pipe. Make
sure the bonding complies with the
relevant regulations in force at the
time of installation.
9.
Turn on the water supply and check
for any leaks.
10. Refit the service tunnel and the
required insert. If necessary, cut out
the slot marked. (Only required if the
inlet water pipe is entering the right
hand side of the shower.)
11. Replace the cover making sure it fits
properly to the case. Do not trap any
wires.
12. Fit the three retaining screws.
13. Install the shower fittings, refer to your
Shower Fittings Installation and
User Guide.
Retaining Screws
Retaining
Screw
17
Caution!
Only use one
set of Live,
Neutral and
(Earth)
connections
within the
shower.
Service
Tunnel

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents