Mira JUMP Installation And User Manual page 25

Electric shower
Hide thumbs Also See for JUMP:
Table of Contents

Advertisement

Malfunction
Water leaks from the
bottom of the case
near the outlet, and
there is no flow from
the showerhead.
The water cannot be
turned off.
Cause
The pressure relief valve
in the tank has been
triggered, (the shower has
a pressure relief valve
assembly that works to
reduce the damage if the
outlet is blocked or the unit
is frozen).
Switch assembly diaphragm
fault.
The flow regulator assembly
is faulty.
Flow valve, solenoid, or
Start/Stop switch faulty.
The supply pressure
is below the minimum
requirement, 50kPa
(0.5 bar).
Resolve the blocked outlet, and
replace the tank assembly.
Replace switch assembly.
Replace.
Diagnose and replace necessary
parts.
Check the static water pressure.
Note that the static pressure may
fall below minimum requirement
when other appliances are drawing
water, for example the dishwasher
or washing machine.
25