Installation; Replacing A Shower - Mira JUMP Installation And User Manual

Electric shower
Hide thumbs Also See for JUMP:
Table of Contents

Advertisement

Replacing a Shower

1.
Check the existing installation is positioned according to the dimensions specified
in the diagram (Fig 1.1). The Mira Jump shower can replace showers of the
approximate shape and size of those shown.
40 mm
150 mm
212 mm
2.
Isolate the electrical and water supplies
before commencing installation. The
electricity must be turned off at the
mains and the appropriate circuit fuse
removed, if applicable.
3.
Disconnect and remove the old shower
from the wall.
4.
Remove the cover and service tunnel
from the Mira Jump shower. Keep the
retaining screws (x3) for later use.
5.
The inlet water supply and electric supply
cable can enter from the directions
shown. Caution! Only use one set of
Live, Neutral and
connections within the shower. Terminal
Blocks are provided on both the left and
right for convenience when replacing a
shower.

INSTALLATION

170 mm
Terminal Block
309 mm
Inlet Water
Supply
50 mm
Fig 1.1
(Earth) electrical
14
45 mm
150 mm
220 mm
170 mm
300 mm
Inlet Water
Supply
55 mm