Explanation: The SunSoft Solaris device driver has been reset because of a device fault.
Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the
Ethernet adapter that fails to respond. If the problem persists, go to "Diagnostic programs" on page 110
to run the diagnostic programs.
pnt0-19
Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris device driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings.
pnt0-20
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-21
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-23
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-24
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-26
Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
pnt0-29
Explanation: The specified I/O address is already in use.
Action: Run the NETCONFIG program to modify your hardware settings.
142
IBM xSeries User's Reference
Device fault...Reset initiated!
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
add_intr_handler failed! Unknown interrupt type.
add_intr_handler failed! Out of range interrupt number.
add_intr_handler failed! Out of range IPL.
add_intr_handler failed! Vector already occupied.
add_intr_handler failed! Vector already shared at different IPL.
The DMA number is not necessary for PCI device.
The IRQ number is already in use.