IBM eServer 240 xSeries User Reference Manual page 139

Hide thumbs Also See for eServer 240 xSeries:
Table of Contents

Advertisement

Result
Test-specific string
Failed
Adapter in slot n; internal error
where n is the slot number of the failing adapter.
Action:
1. Run the ServeRAID Configuration Utility program.
2. If the problem persists, replace the ServeRAID adapter in slot n.
If the problem persists, have the system serviced.
Failed
Adapter in slot n; memory allocation error
where n is the slot number of the failing adapter.
Action: Have the system serviced.
Failed
Adapter in slot n; PCI configuration error
where n is the slot number of the failing adapter.
Action: Replace the ServeRAID adapter in slot n. If the problem persists, have the
system serviced.
Failed
Adapter in slot n; POST error
where n is the slot number of the failing adapter.
Action: Replace the ServeRAID adapter in slot n. If the problem persists, have the
system serviced.
Failed
Logical drive m on adapter in slot n
where m is the number of the failing logical drive and n is the slot number of the
adapter.
Action:
1. Run the ServeRAID Configuration Utility program.
2. If the problem persists, replace the ServeRAID adapter in slot n.
If the problem persists, have the system serviced.
Failed
Logical drive on system board adapter
Action: Run the ServeRAID Configuration Utility program. If the problem persists,
have the system serviced.
Failed
On system board; adapter/drive configuration error
Action: Run the ServeRAID Configuration Utility program. If the problem persists,
have the system serviced.
Failed
On system board; internal error
Action: Run the ServeRAID Configuration Utility program. If the problem persists,
have the system serviced.
Failed
On system board; memory allocation error
Action: Have the system serviced.
Failed
On system board; PCI configuration error
Action: Have the system serviced.
Failed
On system board; POST error
Action: Have the system serviced.
Failed
SCSI drive in bay #n, SCSI ID m
where n is the bay number of the failing drive and m is the SCSI ID of the drive.
Action: Check the cable and power connections on the drive. If the problem
persists, have the system serviced.
Failed
SCSI drive on adapter in slot n, SCSI ID m
where n is the slot number of the adapter and m is the SCSI ID of the drive.
Action: Check the cable and power connections on the drive. If the problem
persists, have the system serviced.
Chapter 6. Solving problems
129

Advertisement

Table of Contents
loading

Table of Contents