NDIS 2.01 (OS/2) device driver messages
This section contains the error messages for the NDIS 2.01 (OS/2) device drivers.
The explanation and recommended action are included with each message.
PCNTND-1 Unable to open the Protocol Manager.
Explanation: The NDIS stack is not configured correctly.
Action: Check and correct your configuration.
PCNTND-6 Out of memory while allocating buffers.
Explanation: The device driver could not allocate the requested buffers.
Action: Check your system configuration. Edit the PROTOCOL.INI file to reduce the number of
Txbuffers and Rxbuffers specified for the device driver.
PCNTND-7 A Protocol Manager device error occurred.
Explanation: The NDIS stack is not configured correctly.
Action: Check and correct your configuration.
PCNTND-8 Bad status for the Protocol Manager.
Explanation: The NDIS stack is not configured correctly in the PROTOCOL.INI file.
Action: Check and correct your configuration.
PCNTND-9 Cannot find the PROTOCOL.INI entry.
Explanation: The NDIS stack is not configured correctly in the PROTOCOL.INI file.
Action: Check and correct your configuration.
PCNTND-10 The Protocol Manager Input Output Control (IOCTL) failed.
Explanation: The NDIS stack is not configured correctly in the PROTOCOL.INI file.
Action: Check and correct your configuration.
PCNTND-11 Protocol Manager registration failed.
Explanation: The NDIS stack is not configured correctly.
Action: Check and correct your configuration.
PCNTND-15 Device not found.
Explanation: The device driver cannot find an Ethernet controller in the server.
Action: Verify that the Ethernet controller is enabled. (See "PCI Slot/Device Information" on page 28.)
If the Ethernet controller is enabled, go to "Diagnostic programs" on page 110 to run the diagnostic
programs.
PCNTND-16 PCI scan specified, device not found.
Explanation: The device driver cannot locate the Ethernet controller on the PCI bus.
Action: Verify that the Ethernet controller is enabled. (See "PCI Slot/Device Information" on page 28.)
If the Ethernet controller is enabled, go to "Diagnostic programs" on page 110 to run the diagnostic
programs.
PCNTND-21 The adapter failed the checksum test.
Explanation: The device driver cannot find an Ethernet controller.
Action: Verify that the Ethernet controller is enabled. (See "PCI Slot/Device Information" on page 28.)
If the Ethernet controller is enabled, go to "Diagnostic programs" on page 110 to run the diagnostic
programs.