kishore vaja
May 15, 2025
I have a wired GT600 601 System connected to telephone line. The lines are going digital soon. Will my old system be compatible with the change or do I need an upgrade.
1 comments:
Mr. Anderson
May 22, 2025
The Risco GT 600/601 system with the Vo-COMM voice dialer is designed to work with standard analog telephone lines. It uses physical telephone line connections (e.g., Terminal 2 and 5 on BT sockets) for signaling. Since digital (VoIP) lines may not provide the same reliability or signaling characteristics as analog lines—especially during power outages—the system may not work reliably over a digital phone line. Therefore, it may require an upgrade or a different communication method (such as GSM or IP modules) for full compatibility with VoIP.
User Manual GT 600 601 Contents User Information ............Introduction ..............User Code Types ............Setting The System ............Setting Unsetting via Keyswitch........Unsetting The System ..........Part Setting The System ..........Quick Part Setting ............Area Setting ..............Removing Zones............
User Manual GT 600 601 User Information Customer Name:- Customer Address:- System Information No of Keypads Keypad 1 Location Type Keypad 2 Location Type Keypad 4 Location Type Keypad 5 Location Type Keypad 6 Location Type Keypad 7 Location Type Keyswitch 1 Location, Area 1, User Code No.
Master Level User Code BS / EN2 (default) - 5678 EN3 (default)- 005678 Several types of User Codes are available on the GT 600 / 601, and each type allows different levels of access. The GT 600 Control Panel can have a total of 31 User codes programmed by a Master Level User Code.
Page 5
User Manual GT 600 601 Area Code Levels (affecting areas only) Area 1 Allows Area 1 Setting, Area 1 Part Setting, Area 1 Unsetting. Cleaner Full System Setting (from unset system), Cleaner Area Unsetting (from set system), Cleaner Part Set (from part cleaner set system).
Page 6
User Manual GT 600 601 Control Code Levels (affecting an output) Control Allows an output that has been pre-programmed by the installation company to be operated. May also have an attribute of Can or Can’t Unset. Control level codes can never Set a system.
User Manual GT 600 601 Setting The System With the display showing:- 01 JAN 18 : 58 : 01 Enter your User code. (Followed by YES if a Master or Main type code EXIT ! 1 has been used). The display will show:- All Zones ON and a continuous exit tone will sound.
User Manual GT 600 601 Pre Exit Check in Wireless Installations This feature is only applicable in wireless fitted installations. A zone (PIR, door contact etc) will be rendered ‘Not Ready’ if it has not been heard by your Control Panel for 20 minutes.
User Manual GT 600 601 Unsetting The System Enter the premises via the authorised entry route (the broken entry tone will sound). Proceed to the keypad. At the keypad enter a valid code, the display will show:- 01 JAN 18 : 58 : 01 The system is now unset.
User Manual GT 600 601 The exit tone may or may not be heard depending on the system settings. Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (depending on system settings).
User Manual GT 600 601 Area Setting (using Master or global Main codes) Areas will need to have been set up by the installation company. With the display showing:- 01 JAN 18 : 58 : 01 Enter a Master or global Main code, the Do you want to .
User Manual GT 600 601 Removing Zones (Master & Main codes only) If programmed by the installation company individual zones may be removed, this may only be done by a Master or Main level of code. If a zone has not been programmed as ‘Remove’...
User Manual GT 600 601 Testing The System (Master & Main codes only) With the display showing:- 01 JAN 18 : 58 : 01 Enter a Master or Main level code, Do you want to . . the display will show:- SET the System ? Do you want to .
User Manual GT 600 601 Whilst in Test mode any zones violated will sound the internal sounder (if it has not been silenced) and show on the display. When you have finished testing the system press 0 twice, the display will show:-...
User Manual GT 600 601 This is the most recent event in the log. Whilst viewing the Log, Pressing NO will move back to the previous event. Pressing YES will move forward to the next event. Pressing 7 will take you to back to the last event of the previous day.
Page 16
User Manual GT 600 601 Press YES the display will show for example:- Chime is Off ok ? Or:- Chime is On ok ? Press NO to change the status of the Chime, Do you want to . . then press YES, the display will show:-...
User Manual GT 600 601 Programming & Deleting User Codes (Master code only) You will be advised by your installation company on the code length required. Under no circumstances should the actual user code be written down. If your installation company has given you keyswitches for the operation of your system the last five user codes may have been reserved for use by these keyswitches.
Page 18
User Manual GT 600 601 Press NO until the Code Type you require is Code Group displayed then press YES. Display will show:- = None ok ? (See pages 3, 4 and 5 for Code Types). Code Groups are only used in conjunction with controlling outputs.
Page 19
User Manual GT 600 601 Referring to the character map enter the required character (pressing the 3 key will display 'G', pressing it again will show 'H' and again will show 'I '), once the correct character is displayed press YES and the display will move on to the next position.
User Manual GT 600 601 Programming Time & Date With the display showing:- 01 JAN 18 : 58 : 01 Enter a Master Code, the display will show:- Do you want to . . SET the System ? Press NO six times, the display will show:- Do you want to .
User Manual GT 600 601 Vo-Comm (if fitted) Vo-Comm is a method of transmitting signals to a standard land-line or mobile telephone giving information regarding the status of your security system. This may be in addition to, or instead of central station communications. It should be noted that Vo- Comm should not under any circumstances be used to ring the Emergency Services directly.
Page 22
User Manual GT 600 601 Enter the telephone number you require followed by YES. Display will show:- VoComm Tel. No.2 is Un-Programmed To enter or change the number repeat from step 7 Display will show:- VoComm Tel. No.3 is Un-Programmed To enter or change the number, repeat from step 7.
Page 23
User Manual GT 600 601 The display will show:- Close Reporting = Off The term Close relates to the system being Set. With Close Reporting set to anything other then Off the Vo-Comm will report the system being closed (Set) for all users who have had the attribute of Vo-Comm Trigger = On allocated in the User Code Programming.
User Manual GT 600 601 Using Vo-Comm (if fitted) Once Vo-Comm has been programmed (see previous page) the Vo-Comm will operate in one of two ways. Alarms Only - The Vo-Comm will only communicate when an alarm occurs on a Closed (Set) system. This mode is active when the Open / Close option is Off.
User Manual GT 600 601 User Initiating Remote Access (Optional) Access Remote allows your installation company to examine your system and re- program system settings as you need the changes without the need for an engineer to visit your premises.
User Manual GT 600 601 Resetting After an Alarm Fault and Alarm Displays Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements. Your installation company will have informed you as to the type of reset that your system is set for.
Page 27
User Manual GT 600 601 Press the YES key to view the next event and carry Zone 005 TAMPER on to view any others (if present). When viewing the 01 JAN 18 : 58 : 01 <- last event the display will show, for example.
Page 28
User Manual GT 600 601 To reset the system with an Anti-Code, contact the central station or engineer (as instructed by the installation company) and quote the number given by the display. The central station or engineer will give a return Anti-Code, (this may contain the YES &...
User Manual GT 600 601 Setting Engineer Authorisation A User Code may be required to authorise an engineer to gain access to the system in the event of service or maintenance schedules. The level of User Code required to authorise the engineer to access the system is set within the User Menu that is accessed via a Master Level Code.
Page 30
User Manual GT 600 601 Do you want to . . Enter a Master User code. The display will show:- SET the System ? Press NO until the display shows:- Do you want to . . Authorise Engnr ? Engnr Authorisor Press YES.
User Manual GT 600 601 Mains Failure Enter Code In the event of a Mains Power Failure the display will show:- ! ! ! ! Check ! ! ! ! At this point the system will revert to battery back-up. The battery will only have a limited time that it can sustain the system for.
User Manual GT 600 601 Exit the premises via the authorised exit route. Once the premises are secure listen (from outside the protected area) and wait until the exit tone finishes before leaving. Re-setting the display after a Mains Fail...
User Manual GT 600 601 Setting the system with Line Fault With the display showing:- 01 JAN 18 : 58 : 01 Enter your User code. Phone Line FAULT The display will then show:- Can’t Set ! Check (Followed by YES if a Master or Main type code has been used).
User Manual GT 600 601 System G-Tag G-Tag Readers are available in three variants, with the reader built into the display area of an LCD RKP, as an Internal Stand alone Reader or as an External Stand alone Reader. When using G-Tag, the system may be Set / Unset by presenting a valid Tag to one of the Readers.
Page 35
User Manual GT 600 601 The readers will be allocated to a specific keypad. The G-Tag information is stored in the keypad therefore a single keypad having two readers would only require the G-Tag to be programmed into one of its readers For multiple keypads with readers the sequence for programming the G-Tags would Enter User Programming Mode.
User Manual GT 600 601 Advanced Code Programming (Control Codes) Codes may be programmed to control Outputs and Unset the system. The Outputs that may be controlled will have been pre-programmed by your installation company and may not be changed by the user. A Master user however does have the ability to allocate the codes (not User No.1) to these Group Outputs...
Page 37
User Manual GT 600 601 Press NO until the Grp you wish to control is displayed. (For example Grp1). Then Press YES. Note: If a Code level other than Control has been chosen, the selected Output Group will be activated each time the code is used. The use of the code will be as normal for that level of code.
Page 38
User Manual GT 600 601 If you wish to accept the User Name shown press User 02 Name YES and jump to step 18 = User 02 If you wish to change the User Name shown press User 1 Name NO, the display will show:- >...
User Manual GT 600 601 Advanced Setting and Unsetting Using Group Area Codes There are three levels of Group Area Codes. Group Master Allows Setting, Part Setting, Area Setting, Zone Remove, System Test, Viewing the Log, Chime On/Off, Program User Codes, Set Time/Date, Unsetting.
User Manual GT 600 601 Programming Group Area User Codes With the display showing:- 01 JAN 18 : 58 : 01 Do you want to . . Enter a Master Code, the display may show:- SET the System ? Do you want to . .
Page 41
User Manual GT 600 601 This determines if using this user code to VoComm Trigger set the system will trigger the Vo-Comm. = On Ok ? (For more details on Vo-Comm please refer to the Vo-Comm section). Press NO until the setting you require is displayed (YES or NO).
Page 42
User Manual GT 600 601 As you press YES for the ninth character (or if you have jumped from step 11) the display will Do you want to . . change to:- Prog. USER CODES ? If you wish to program other User Codes return to step 4.
User Manual GT 600 601 Setting Using Group Master & Group Main Codes Group Master & Group Main codes follow global Master & Main codes with respect to the level functionality. The difference lies in the ability to have individual control of the Areas that been allocated to the code.
User Manual GT 600 601 Unsetting Using Group Area Code Follow the instructions as for normal Unsetting. When you are using a Group Area Code only the Area(s) allocated to that code will be Unset. Unsetting Using Group Master & Group Main Codes With the display showing:- (Areas 1 &...
User Manual GT 600 601 Adding Areas to a System with Area(s) Already Set Group Master & Group Main Codes If your system already has an Area or Areas already Set you may add more Area(s) as required. With the display showing for example:- 01 JAN 18 : 58 : 01 (Area 1 is already Set).
User Manual GT 600 601 Display Blanking Depending on the level of your system and the legislation that it is required to comply with your installation company may have initialised Display Blanking. When this is used the Status of the system will only be indicated on the display for ten seconds after it has been Set and for ten seconds after it has been Unset.
User Manual GT 600 601 Keypad Alert If programmed by your installation company, the two PA keys when pressed together will act as alert keys. The exact function will depend on what they have been programmed for. But, for example, if they are programmed as panic, pressing them will activate the alarm when the system is set or unset.
User Manual GT 600 601 User Chart Please use this chart to indicate what user names have been programmed onto your system and those that are in use. Under no circumstances should the actual user code be written down. User’s 32 - 99 applicable to GT 601 Control Panel only...
Page 53
User Manual GT 600 601 User Chart cont. In Use Name In Use Name User 51 User 76 User 52 User 77 User 53 User 78 User 54 User 79 User 55 User 80 User 56 User 81 User 57...
Page 56
RISCO Group UK Ltd Commerce House, Whitbrook Way Stakehill Distribution Park, Middleton. Manchester. M24 2SS United Kingdom Internet: www.riscogroup.co.uk e-mail: sales@riscogroup.co.uk RISCO Group UK Ltd reserve the right to amend the software and features without prior notice PR600601_1 Rev1.0 5IN1434 A...
Need help?
Do you have a question about the GT 600 and is the answer not in the manual?
Questions and answers
I have a wired GT600 601 System connected to telephone line. The lines are going digital soon. Will my old system be compatible with the change or do I need an upgrade.
The Risco GT 600/601 system with the Vo-COMM voice dialer is designed to work with standard analog telephone lines. It uses physical telephone line connections (e.g., Terminal 2 and 5 on BT sockets) for signaling. Since digital (VoIP) lines may not provide the same reliability or signaling characteristics as analog lines—especially during power outages—the system may not work reliably over a digital phone line. Therefore, it may require an upgrade or a different communication method (such as GSM or IP modules) for full compatibility with VoIP.
This answer is automatically generated