6.28 Address 34 - System Report
• System Trouble: This report is sent when a control
trouble condition occurs.
• System Trouble Restoral: This report is sent when
all system trouble conditions restore.
6.29 Address 35 - Exit Error, Recent Closing,
Comm. Failure Report
• Exit Error: This report is sent if an exit error occurs.
An exit error occurs when an entry/exit zone is still
violated at the end of the exit delay. If this happens, the
entry delay will begin. If the system is not disarmed
before the entry delay expires, an alarm report for the
effected zone will be sent and the Exit Error Report will
be sent.
• Recent Closing: This report is sent, along with any
alarm reports, when there is an alarm within the first
five minutes after the system has been armed.
• Comm. Failure Report: This report is sent after the
programmed number of communicator attempts. Refer
to Address 22 - Dial Attempts.
Page 18
Copyright © 2001 Detection Systems, Inc.
• Comm. Restore Report: This report is sent after
there has been a communicator failure. Retries will
occur after 30 minutes, then every 24 hours or when a
new event occurs. When the next successful
communicator attempt occurs, this report will be
included.
6.30 Address 36 - Test Reports, System Test
• Automatic Test Report: This report is sent at fixed
intervals determined by programming Address 48 -
Automatic Test Report Interval. By default, the panel
will send the first automatic report 12 hours after the
panel has been powered up, and from that point on, it
will follow the interval selected by Address 48. The
time before the first Automatic test report is sent can
be adjusted between 1 and 24 hours after the panel
has been powered up by setting Address 49 - Hours to
First Auto Test Report.
• Communicator Test Report: This report is sent as a
result of initiating a Communicator Test, a PIN + [#] [8]
[2] command sequence. Requires that Addresses 37
"Account Code", 38 "Phone # 1 Format" and 40 "Phone
#1 be programmed.
• System Test: This report is sent when a system test
has been started using the [#] [8] [1] key sequence.
• System Test Restoral: This report is sent when the
system test [#] [8] [1] has been completed or has
timed-out.