Reports
Program locations 24 through 36 are used differently for
the particular Phone Format Chosen (see Address 38,
39). If Zone Doubling is selected in Address 55, Fire and
Tamper reports are programmed in Addresses 56 and 57
for Zones 7 and 8.
• If a value of 00 is programmed in any of these
locations the panel will not send that particular report.
• Pulsed Formats (3/1, 3/1E, 3/1 with Parity, 3/1E with
Parity, 4/1, and 4/2) will need a unique value placed at
each address location. Please note that each Central
Station receiver differs slightly in the report codes that
it expects. Therefore, it is best to verify the codes you
use with the Central Station. Some of the reports that
can be sent, such as OPEN, CLOSE, PARTIAL
CLOSE can send an associated User Number as the
second digit. To accomplish this, program an F (*5) as
the second digit in the program location. When the
report is sent the panel will replace the F with the
appropriate user number. Pulsed formats 3/1, 3/1 with
Parity, and 4/1 need a 0 for the second digit and
cannot send user numbers. A non-zero in the second
digit location indicates an extended 3/1E or 4/1E
format.
• Fixed Report Formats (Contact ID, SIA, 4/9) have
well defined reports that are sent regardless of the
value programmed in the report code location. Any
non-zero value programmed in the report code location
will send the appropriate report.
• Special Formats (Personal Dialing Format, Pager) are
not recommended for primary reporting. If they are
used, Personal Dialing Format could use the same
report codes as the Pulsed Formats. Pager has a
limitation in that it can't use the Hex values A (*0), B
(*1), C (*2), D (*3), E (*4), F (*5). These values can not
be passed on to a Numeric Pager.
6.18 Address 24 - Keypad Report
DS7060-AUS Reference Guide
Copyright © 2001 Detection Systems, Inc.
• Keypad Fire Report: This report is sent when a fire
alarm has been activated using the "A" emergency key.
• Keypad Fire Restoral Report: This report is sent
when a keypad fire alarm has been restored using the
[System Reset] command.
• Keypad Help Alarm Report: This report is sent when
an help alarm has been activated using the "B"
emergency key.
• Keypad Panic Report: This report is sent when an
emergency alarm has been activated using the "C"
emergency key.
6.19 Address 25 - Zone Alarm Report
• Zone Alarm: An alarm report is sent when a zone
alarm occurs. Program this report for any zones where
an alarm report is desired. For local zones (no
reports), replace the default value with 00.
6.20 Address 26 - Zone Alarm Restoral Report
• Zone Alarm Restoral: This report is sent when the
zone alarm is cleared. Refer to Address 07 for exact
point at which report will be sent.