6

TROUBLESHOOTING

PROBLEM
The electric starter does
not turn
The engine turns over but will
not start
The power delivered by the
engine is insuffi cient
The motor stops or splutters
Engine overheats
Front braking poor
Rear braking poor
GB
CAUSE
Key in position
Flat battery
Blown fuse
Defective relay
Defective starter motor
Fuel cock in OFF position
Dirty carburettor jets
Spark plug oily or wet
Spark gap wrongly adjusted
Fault in the ignition system
Tank vent obstructed
Fuel system dirty
Air fi lter dirty
Defective ignition system
Lack of fuel
Poor carburettor seal
Loose or oxidized connector or ignition
coil
Insuffi cient air fl ow
Silencer partly clogged
Carburation too lean
Brake pads worn
Air or humidity in the hydraulic circuit
Brake pads worn
Air or humidity in the hydraulic circuit
62
REMEDY
Move the key on
Check the battery
Replace
Contact authorised BETAMOTOR customer
service
Contact authorised BETAMOTOR customer
service
Move the fuel cock to ON or RES position
Contact authorised BETAMOTOR customer
service
Clean and dry the spark plug, replace if
necessary
Restore the spark gap
Contact authorised BETAMOTOR customer
service
Check the tank vent
Contact authorised BETAMOTOR customer
service
Clean air fi lter
Contact authorised BETAMOTOR customer
service
Move the fuel cock to RES
Refuel
Make sure that the hose between carbure-
tor and engine is intact
Check the connector. Clean and treat with
specifi c spray
Stop the engine when vehicle is stationary
Contact authorised BETAMOTOR customer
service
Contact authorised BETAMOTOR customer
service
Contact authorised BETAMOTOR customer
service
Contact authorised BETAMOTOR customer
service
Contact authorised BETAMOTOR customer
service
Contact authorised BETAMOTOR customer
service