c) Precaution for mounting the roller
When mounting the cassette pick-up roller, fit the projection[A] on the cassette pick-up roller holder[1] in the grooves in the cassette pick-up roller.
d) Removing the cassette separation roller
1) When removing the cassette separation roller, first open the top cover,and then remove the back cover, left and right covers, tank cover, right upper cover, oper-
ation panel mist filter, filter cover, filter, left and right covers, lower rear cover, and lower back cover.
2) Remove the cassette pick-up sensor[3] by removing the screw[1] and connector[2].
3) Then the gear[1] to make sure that the pick-up cam[2] is at the position shown below(the arm[3] is raised).
4) Remove one ring[1] and two gears[2].
F-4-59
[1]
[2]
F-4-60
[1]
F-4-61
[1]
F-4-62
[1]
[A]
[3]
[3]
[2]
Chapter 4
[2]
4-25