erwise, the flexible cable can damage, resulting in malfunction.
8) Insert flat-head screwdriver[3] into the part shown to release hook[2] and then remove flexible cable retainer[1]. (If flexible cable retainer[1] is marked with
index[A], insert the flat-head screw driver to meet the index.)
9) Turn the gear[1] so that the sensor flag of the lift gear[2] leaves the interrupt position of the lift cam sensor[3], then remove the ring[4], the lift gear[2] and the
lift cam[5]. Disconnect the connector[6], remove the two screws[7], and then remove the lift cam sensor[3]. Remove the two torsion springs[8], pull out the
carriage rail[9] from the right side of the printer, and then remove the carriage.