(9) Adjusting the DP magnification

Adjust magnification in the auxiliary scanning direction if magnification is incorrect when the DP is used.
U065
U070
(P. 1-6-44)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Enter maintenance mode.
Press the system menu/counter key.
Place an original on the DP
(Printing cannot be stopped until the
preset number of sheets is printed.)
to exit maintenance mode.
Y104230-6
Start
Enter 070 using
up/down cursor keys.
Press the enter key.
and make a test copy.
Is the image correct?
Yes
Press the back key
End
Original
Press the enter key.
The new setting is stored.
Press the system menu/counter key.
For copy example 1, increase the
No
value using the right cursor key.
For copy example 2, decrease the
value using the left cursor key.
Setting range: -25 to +25
Initial setting: -2
Changing the value by 1 changes
the magnification by 0.1%.
Increase the value makes
the image longer, and decreasing it
make the image shorter.