Regency HZ33CE
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-366
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Owners &
Installation Manual
MODEL: H
33CE-NG10 Natural Gas
Z
H
33CE-LP10 Propane
Z
HZ33CE Video
www.regency-fire.com
02.09.15

Advertisement

Table of Contents
loading

Summary of Contents for Regency HZ33CE-NG10

  • Page 1 Owners & Regency HZ33CE Installation Manual Gas Fireplace MODEL: H 33CE-NG10 Natural Gas 33CE-LP10 Propane HZ33CE Video www.regency-fire.com WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The HZ33CE has been ® designed to provide you with all the warmth and charm of a fire at the flick of a switch. The model HZ33CE has been approved by Warnock Hersey for both safety and efficiency.
  • Page 3: Manufactured Mobile Home Requirements

    This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit # 434-972). Ensure that structural members are not cut or weakened during installation. Horizon Benefits Video HZ33CE Video Regency HZ33CE-10 Gas Fireplace...
  • Page 4: Table Of Contents

    Unit installation with Horizontal termination ....29 Main Assembly ............51 Unit installation with Vertical Termination ....30 Accessories ..............51 Gas Line Installation ............30 Pilot Adjustment ............31 High Elevation .............31 WARRANTY 885 S.I.T. Valve Description .........31 The Warranty: Limited Lifetime ........55 Regency HZ33CE-10 Gas Fireplace...
  • Page 5: Copy Of Safety Decal

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency HZ33CE-10 Gas Fireplace...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency HZ33CE-10 Gas Fireplace...
  • Page 7: Dimensions

    UNIT DIMENSIONS 23" 584mm 2-1/2" 34-9/16" [64mm] [878mm] NAILING STRIP 3" (76mm) 26" 660mm 29-7/16" 747mm 4 SIDED FACEPLATE DIMENSIONS 42-5/16" (1074mm) 2" (51mm) Regency HZ33CE-10 Gas Fireplace...
  • Page 8: Installation

    National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 3. See general construction and assembly in- structions. The appliance and vent should be enclosed. Regency HZ33CE-10 Gas Fireplace...
  • Page 9: Installation Checklist

    11. Final check. Diagram 1 Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer. Flat on Wall Corner Recessed into Wall/Alcove Corner Regency HZ33CE-10 Gas Fireplace...
  • Page 10: Clearances

    1-1/4" D: Alcove Width 84" (1219mm) Sidewall to Sidewall (Minimum) E: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) F: Mantel 12" (305mm) G: Mantel Clearances From Top Opening of Unit 15-3/4" (400mm) 10 | Regency HZ33CE-10 Gas Fireplace...
  • Page 11: Mantel Leg Clearances

    Standoff 24-1/4"(616mm) Top opening to floor of Unit Side View MANTEL LEG CLEARANCES Combustible mantel leg clearances from side of unit as per diagram: Top View Side opening of Unit 6-3/4" Allowable mantel leg projection 9" Regency HZ33CE-10 Gas Fireplace...
  • Page 12: Framing & Finishing

    Non-combustible Material (3-1/2" x 34-9/16") Supplied with Unit Non-combustible Nailing Strip -1/2" back from unit face Finishing Material (ie. tile) Ensure finished material is brought to lip Non-combustible Finishing Material (ie. tile) Combustible Material 29-7/16" 747mm 12 | Regency HZ33CE-10 Gas Fireplace...
  • Page 13 While every precaution is taken in providing the recommendations on preparation and finish, given the variations in paint quality, with temperature limits and workmanship in application, Regency is unable to guarantee the life of the joint compounds, paint or any other finish materials or workmanship applied to or used in any application surrounding the fireplace.
  • Page 14: Clean Finish

    To maintain a clean finished edge - facing material edges may be finished with a J-style trim or metal cornerbead (both materials available at your local building or hardware store). IMPORTANT: Materials used must be NON-COMBUSTIBLE. 14 | Regency HZ33CE-10 Gas Fireplace...
  • Page 15: Framing Dimensions

    36" (914mm) Rigid 32" (812mm) Flex 30" (762mm) Rigid 26" (660mm) Flex Vent Centerline Height* Gas Connection Height* 1 1/2" (38mm) Gas Connection Inset* 7-3/16" (183mm) Gas Connection Width* 3" (76mm) * Measured from base of unit. Regency HZ33CE-10 Gas Fireplace...
  • Page 16: Venting Introduction

    Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. (See "Rigid Pipe Venting System" for more details and exceptions). NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met. 16 | Regency HZ33CE-10 Gas Fireplace...
  • Page 17: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency HZ33CE-10 Gas Fireplace...
  • Page 18: Regency ® Direct Vent Flex System

    (8. screws #8 x 1-1/2" drill point, stainless steel (4. Notes: 1. Liner sections should be continuous without any joints or seams. 2. Only Flex pipe purchased from Regency ® may be used for Flex installations. Alternate Horizontal Termination...
  • Page 19: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace ® Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency HZ33CE-10 Gas Fireplace...
  • Page 20: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com 20 | Regency HZ33CE-10 Gas Fireplace...
  • Page 21 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 22: Rigid Pipe Venting Arrangements

    Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. • Vent must be supported at offsets. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994.. 22 | Regency HZ33CE-10 Gas Fireplace...
  • Page 23: Vertical Termination With Co-Linear Flex System

    46DVA-VCH High Wind Cap 46DVAGK 3" Co-linear Adapter with flashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adaptor Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency HZ33CE-10 Gas Fireplace...
  • Page 24: Venting Arrangements - Vertical Terminations

    Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Floor Floor Horizontal Distance (Feet) Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. 24 | Regency HZ33CE-10 Gas Fireplace...
  • Page 25: Horizontal Terminations

    Maintain clearances to combustibles. 8"(0.2m) • Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. 2’ (0.6m) Minimum Minimum Simpson Dura-Vent Center-Line Flex Kit Center-Line Regency HZ33CE-10 Gas Fireplace...
  • Page 26 8 feet total horizontal. 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. 26 | Regency HZ33CE-10 Gas Fireplace...
  • Page 27 5' Min. 1 foot between 90 required. elbows is required. 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency HZ33CE-10 Gas Fireplace...
  • Page 28 4' Min. 5' Max. 7' Min. Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. 28 | Regency HZ33CE-10 Gas Fireplace...
  • Page 29: Unit Installation With Horizontal Termination

    Failure to do so may result in drafting or performance issues not cov- ered under warranty. b) Horizontal runs of vent must be supported every three feet. Wall straps are available for this purpose. Regency HZ33CE-10 Gas Fireplace...
  • Page 30: Unit Installation With Vertical Termination

    Do not use open flame for leak testing. of the flashing to the roof with roofing rails, slide storm collar over the pipe section and Diagram 2 seal with a mastic. 30 | Regency HZ33CE-10 Gas Fireplace...
  • Page 31: Pilot Adjustment

    GAS PIPE PRESSURE PILOT ADJUSTMENT HZ33CE-NG10 System Data TESTING Periodically check the pilot flames. Correct flame pattern has two strong blue flames: Conversion Kit# 433-971 (NG to LP) The appliance must be isolated from the gas 1 flowing around the flame sensor and 1...
  • Page 32: Conversion From Ng To Lp

    14. Check inlet and outlet pressures. orifi ce in the kit and replace pilot cap. 15. Check operation of fl ame control. Installer Notice: These instructions must be left with the appliance Diagram 6 Diagram 2 06.09.14 919-433 32 | Regency HZ33CE-10 Gas Fireplace...
  • Page 33: Wiring Diagram

    NG with Stones 3/16” Note: Any damage due to carboning resulting from improperly setting 3/16" the aeration controls is NOT covered LP with Logs Full open under warranty. LP with Stones Full open Regency HZ33CE-10 Gas Fireplace...
  • Page 34: Optional Fan Installation

    FAN MOTORS ON A REGULAR BASIS BY VACUUMING 4. Connect the power cord and fan ground wires to the ground lug. Refer THE FAN BLADES AND THE HOUSING WITH A SOFT to wiring diagram BRUSH NOZZLE. 34 | Regency HZ33CE-10 Gas Fireplace 919-423 08/14/14...
  • Page 35 Fan Control Module marked “COM”. Turn the switch on theFan Control Module to the On position. On is to the left. The “O” is the off position 919-423 08/14/14 Regency HZ33CE-10 Gas Fireplace...
  • Page 36: To Remove The Fan

    12. See the Profl ame instructions for coding the remote handheld to the receiver and for operating instructions. 13. Reverse Steps 6 -1 to complete the installation. 36 | Regency HZ33CE-10 Gas Fireplace 08/14/14 919-423...
  • Page 37: Wiring Diagram With Optional Fan

    SureFire™ Switch Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency HZ33CE-10 Gas Fireplace...
  • Page 38: Optional Reflective Panel Installation

    4. With the top panel in place - install back panel. The back panel fits under the top panel, push the top panel up to fit back panel into position. (Diagram 3) Completed Panel Installation Diagram 3 Note: Diagram is shown without a burner. Back Panel 38 | Regency HZ33CE-10 Gas Fireplace...
  • Page 39: Glass Crystals And Optional Stones

    The Burner and Firebox Floor should not be visible when the flame is out. OPTIONAL SPA STONES INSTALLATION (AROUND BURNER NOTE: Spa/Volcanic stones are NOT to be placed anywhere on the burner tube or Pilot assembly area. Regency HZ33CE-10 Gas Fireplace...
  • Page 40: Optional Log Set Installation

    9. Place Log 4 on the glass on the right side in location shown below. HZ33CE - install bracket, left side HZ33CE shown - Logs 1,4 and 5 in position. 40 | 919-265 07/10/13 Regency HZ33CE-10 Gas Fireplace...
  • Page 41 Log 2 rests on the burner tray as shown below. 13. Adjust aeration, see unit manual for setting. HZ30E use top pin landing HZ33CE shown - Final Install HZ30E shown - installing Log 2 Regency HZ33CE-10 Gas Fireplace 919-265a 06.10.14...
  • Page 42 6. Place lava embers/rocks on glass - ensure rocks do not block pilot. Do not place lava rocks/embers too close to logs as this may cause carboning. 7. Adjust aeration, see unit manual for setting. HZ30E shown - Final Install 42 | Regency HZ33CE-10 Gas Fireplace 919-265a 06.10.14...
  • Page 43: Glass Door And Mesh Barrier Installation

    (see below). Diagram 1 Hooks on mesh barrier frame 2. When hooks are clear of the bracket–tilt mesh frame out slightly from the bottom and manoeuvre mesh out. Diagram 2 3. To reinstall–reverse steps. Diagram 3 Regency HZ33CE-10 Gas Fireplace...
  • Page 44: Optional 4-Sided Faceplate Installation

    Diagram 2 -Bracket screw locations on unit. 2. Install four (4) wood screws, two (2) on each side of the bracket into the wall studs as shown below. Diagram 6 -Final Install Diagram 3 -Bracket screw locations. 44 | Regency HZ33CE-10 Gas Fireplace...
  • Page 45: Operating Instructions Operating Instructions

    The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency HZ33CE-10 Gas Fireplace...
  • Page 46: Lighting Procedure

    (see Diagram 2). An audible beep should be heard from the receiver. 3. Turn the gas control knob to the "OFF" position to turn off the pilot. ON/OFF Button Diagram 2 Remote shown in Manual Mode on Hi 46 | Regency HZ33CE-10 Gas Fireplace...
  • Page 47: Copy Of Lighting Plate Instructions

    Utilisez l'interrupteur murale ON/OFF du Brûleur ou du contrôle à distance pour éteindre le brûleur. Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a Regency HZ33CE-10 Gas Fireplace...
  • Page 48: Maintenance Maintenance Instructions

    Replacement of the glass panels 8. Verify operation after servicing. should be done by a licensed or qualified service person. 48 | Regency HZ33CE-10 Gas Fireplace...
  • Page 49: Valve Tray Replacement

    Diagram 2 1. Install new Valve Tray Assembly. 6. Disconnect the inlet gas line. 2. Reverse steps 8-1. 7. Disconnect the EV1, EV2, and ground wires from the valve - as shown below. Ground Diagram 3 Regency HZ33CE-10 Gas Fireplace...
  • Page 50: Parts List

    • 910-011 Stepper Motor/ Modulator LP • 910-100 Pilot Orifice NG 940-330/P Replacement Glass with Gasket • 910-101 Pilot Orifice LP • 911-137 Pilot Clip • 437-018 Access Plate • W840470 Pilot Assembly Gasket 50 | Regency HZ33CE-10 Gas Fireplace...
  • Page 51: Main Assembly

    946-737 Glacier Ice Firebeads 946-710 Volcanic Stones Slate/Grey 946-738 Caramel Luster Firebeads 946-711 Volcanic Stones Ivory/Tan 5 POUND BAG OF FIREBEADS 946-739 Black Firebeads 946-740 Sangaria Luster Firebeads 946-741 glacier ice firebeads 946-742 Caramel Luster Firebeads Regency HZ33CE-10 Gas Fireplace...
  • Page 52 52 | Regency HZ33CE-10 Gas Fireplace...
  • Page 53 Regency HZ33CE-10 Gas Fireplace...
  • Page 54 54 | Regency HZ33CE-10 Gas Fireplace...
  • Page 55: Warranty

    Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly ® before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This ®...
  • Page 56 ___________________________________________________________________ HZ33CE Video Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Horizon and SureFire are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2014, FPI Fireplace Products International Ltd. All rights reserved.