Summary of Contents for Regency Horizon HZ30E-NG10
Page 1
Regency Horizon ™ HZ30E Owners & Installation Manual Gas Fireplace MODELS: -NG10 Natural Gas -LP10 Propane Horizon HZ30E Product Video www.regency-fire.com WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH, in Canada. Regency Horizon Horizon HZ30E Product Video Gas Insert Benefits Video Regency Horizon HZ30E-10 Gas Fireplace...
Page 3
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The HZ30E has been ® designed to provide you with all the warmth and charm of a fireplace at the flick of a switch.
Valve assembly Replacement ........54 Unit Installation with Horizontal Termination ....33 Main Assembly ............56 4" x 6-5/8" venting ............33 Accessories ..............58 Unit Installation with Horizontal Termination ....34 The Warranty: Limited Lifetime ........59 Unit installation with Vertical Termination ....35 Regency Horizon HZ30E-10 Gas Fireplace...
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency Horizon HZ30E-10 Gas Fireplace...
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Horizon HZ30E-10 Gas Fireplace...
National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 3. See general construction and assembly instructions. The appliance and vent should be enclosed. Regency Horizon HZ30E-10 Gas Fireplace...
14. Final check. Flat on Wall Before leaving this unit with the customer, the Flat on Wall Corner installer must ensure that the appliance is firing Recessed into Wall/Alcove correctly and operation fully explained to Corner customer. Regency Horizon HZ30E-10 Gas Fireplace...
Sidewall to Sidewall (Minimum) F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) G: From Floor 21" (533mm) Top of Fireplace Opening Note: 0" No hearth required Installed Close to Floor Unit Alcove 10 | Regency Horizon HZ30E-10 Gas Fireplace...
13-1/4” To Unit 21” Base Top of Fireplace Opening MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 2”(51mm) MANTEL LEG Non-Combustible 1.5" (38mm) 5-1/2” (140mm) Allowable mantel leg projection 8” (203mm) 11” (279mm) Regency Horizon HZ30E-10 Gas Fireplace...
3. Install any optional components with access panel removed. Screw Locations 4. Reinstall access panel with 2 screws - prior to installing any facing material Note: Access panel is no longer usable once facing material installed. Installation Access Panel 12 | Regency Horizon HZ30E-10 Gas Fireplace...
11. Using the two (2. screws provided secure the cover plate to the Receiver. Low Voltage Junction Box J-Box Receiver Slider Switch Wall Plate 12 pin connector - located on outer right side of the firebox. Regency Horizon HZ30E-10 Gas Fireplace...
4. Attach both vertical studs and secure using 6 screws (2 at bottom, 2 at top and 2 on sides) as shown. NOTE: Ensure the flat side of the steel stud is facing the wood framing. Regency Horizon HZ30E-10 Gas Fireplace Flat side out...
28-7/8” Important: 1/2" gap required between faceplate and finished wall when using part #316-924, 316-927 (4 pc. faceplate). When using part # 316-934 and 316-937 (outer faceplate) the 1/2" gap is not necessary. 16 | Regency Horizon HZ30E-10 Gas Fireplace...
3-1/8" 0" (flush) application, Regency is unable to guarantee the life of the joint compounds, paint or any Finished material other finish materials or workmanship applied to or used in any application surrounding the fireplace.
* Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally 18 | Regency Horizon HZ30E-10 Gas Fireplace...
4” X 6- 5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Description...
Page 20
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
4. Once the vent restrictor plate is in the required position, secure with screws. SET 0 (Factory set) VENT RESTRICTOR AT 1-3/4”” 1-3/4” SET 1 THIS HOLE SETS THE VENT RESTRICTOR AT 1-1/4” 1-1/4” SET 2 THIS HOLE SETS THE VENT RESTRICTOR AT 3/4” 3/4” Regency Horizon HZ30E-10 Gas Fireplace...
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet.
S.S. screws #8 x 1-1/2” drill point Notes: 1. Liner sections should be continuous without any joints or seams. 2. Only Flex pipe purchased from Regency may be ® used for Flex installations 3. Horizontal vent must be supported every 3 feet.
American Metal Products Ameri Vent Direct Vent, Security Secure Vent , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI ® Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 24 | Regency Horizon HZ30E-10 Gas Fireplace...
Page 25
With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Please note the minimum centerline for basic install shown above. Regency Horizon HZ30E-10 Gas Fireplace...
4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. Restrictor Position - Set 0 (factory setting) 26 | Regency Horizon HZ30E-10 Gas Fireplace...
Page 27
1 f o o t 6' Min. 5' Max. 10' Min. 8' Max. between 90 elbows 7' Min. 6' Max. 12' Min. 9' Max. is required. Restrictor Position - Set 0 (factory setting) Regency Horizon HZ30E-10 Gas Fireplace...
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set 2 if required. Vent Restrictor on Set 2 Vent Restrictor on Set 1 28 | Regency Horizon HZ30E-10 Gas Fireplace...
3/4” open Horizontal Distance (Feet) Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations when using two- 3" co-linear aluminium flex and 4 x 6-5/8" rigid pipe. Regency Horizon HZ30E-10 Gas Fireplace...
5' Max. 5' Min. 1 foot between 90 required. elbows is required. 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. Restrictor Position - Set 0 (factory setting) Restrictor Position - Set 0 (factory setting) Regency Horizon HZ30E-10 Gas Fireplace...
Page 32
Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. Restrictor Position - Set 0 (factory setting) 32 | Regency Horizon HZ30E-10 Gas Fireplace...
3 supplied screws (drilling pilot holes will make this easier). 4. Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips. Diagram 7 Diagram 2 Diagram 1 Regency Horizon HZ30E-10 Gas Fireplace...
(10" (254mm) and slip it over the outer flue collar of the vent Outer Diameter) terminal at least 1-3/8"(35mm) and fasten with the 3 screws. 34 | Regency Horizon HZ30E-10 Gas Fireplace...
Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. Regency Horizon HZ30E-10 Gas Fireplace...
Note: Any damage due to carboning resulting screw (clockwise) with a 1/8" flat screwdriver. from improperly setting the aeration Note: Screw should be snug, but do not over controls is NOT covered under warranty. tighten. 36 | Regency Horizon HZ30E-10 Gas Fireplace...
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon HZ30E-10 Gas Fireplace...
These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming the fan blades and the housing with a soft brush nozzle. 38 | Regency Horizon HZ30E-10 Gas Fireplace...
Page 39
10. Attach the green ground wire to the ground lug – located in the lower back corner of the unit. 6. Remove the valve access plate by removing the 17 outer screws – see locations below Regency Horizon HZ30E-10 Gas Fireplace...
Page 40
Fan Control Module marked “COM”. Turn the switch on the Fan Control Module to the ON position. ON is to the left. The “O” is the off position 40 | Regency Horizon HZ30E-10 Gas Fireplace...
CAUTION: Label all wires prior to disconnection Caution: Ensure that the wires do not touch any when servicing controls. Wiring errors can cause hot surfaces and are away from sharp edges. improper and dangerous operation. Regency Horizon HZ30E-10 Gas Fireplace...
5) Reinstall glass door - reinstall faceplate. 3) Install the left side panel - secure in position with one panel clip and 6) Final installation one screw, as shown in the diagram below. 42 | Regency Horizon HZ30E-10 Gas Fireplace 05/16/13 918-901a...
9. Place Log 4 on the glass on the right side in location shown below. HZ33CE - install bracket, left side HZ33CE shown - Logs 1,4 and 5 in position. 44 | 07/10/13 919-265 Regency Horizon HZ30E-10 Gas Fireplace...
Page 45
Log 2 rests on the burner tray as shown below. 13. Adjust aeration, see unit manual for setting. HZ30E use top pin landing HZ33CE shown - Final Install HZ30E shown - installing Log 2 Regency Horizon HZ30E-10 Gas Fireplace 919-265 07/10/13...
Page 46
6. Place lava embers/rocks on glass - ensure rocks do not block pilot. Do not place lava rocks/embers too close to logs as this may cause carboning. 7. Adjust aeration, see unit manual for setting. HZ30E shown - Final Install 46 | Regency Horizon HZ30E-10 Gas Fireplace 07/10/13 919-265...
See Diagram 2. Diagram 3 Diagram 1 Hook top of door onto top flange Flush Door Diagram 2 Regency Horizon HZ30E-10 Gas Fireplace...
Page 48
7. Secure the assembly with screws on each side as shown below. 3. Install screen into inner door trim (3). Secure screen by bending down the 6 tabs as shown Tabs Regency Horizon™ HZ40E-10 Gas Fireplace 48 | Regency Horizon HZ30E-10 Gas Fireplace...
Inner door frame may be installed by itself, or with the outer door frame. The outer door frame cannot be installed by it- self - if installing the outer door frame - the inner door frame must also be installed. Regency Horizon HZ30E-10 Gas Fireplace 919-450 09.29.14...
Page 50
It is recommended that you use the fi rst mounting slot. NOTE: There are 3 mounting slots available, this is to accommodate any fi nishing that protrudes slightly beyond the surround. Completed glass surround installation 50 | Regency Horizon HZ30E-10 Gas Fireplace 09.29.14 919-451...
1. Turn the wall mounted switch or remote to the "OFF" position. Button 2. Press "OFF" on the remote control. 3. Turn the gas control knob to the "OFF" position to turn off the pilot. Diagram 2 Remote shown in Manual Mode on Hi 52 | Regency Horizon HZ30E-10 Gas Fireplace...
Utilisez l'interrupteur murale ON/OFF du Brûleur ou du contrôle à distance pour éteindre le brûleur. Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a Regency Horizon HZ30E-10 Gas Fireplace...
& reinstalled in accordance with the manufacturer's instructions. Replacement of the glass panels should be done by a licensed or 8. Verify operation after servicing. qualified service person. 54 | Regency Horizon HZ30E-10 Gas Fireplace...
* Prior to removing burner - remove crystals, pebbles, spa stones and inner panels - if installed. Location of screws on access plate 6. Loosen 2 screws at the back of the burner to release it. Regency Horizon HZ30E-10 Gas Fireplace...
Page 56
7. Partially lift out valve tray - use extreme caution, the thermodisc needs to be removed before valve tray is lifted out completely. Thermodisc 8. Disconnect the inlet gas line and remove the valve assembly. 9. Replace valve assembly and reverse steps. 56 | Regency Horizon HZ30E-10 Gas Fireplace...
Manual 910-101 Pilot Orifice LP 911-037 Flame sensor 911-038 Flame Electrode 911-039 2 flame pilot hood 911-137 Pilot Clip 910-432 Pilot Tube 910-142 Fan Thermodisc W840470 Pilot Assembly Gasket 904-658 Inlet gas flex line SS Regency Horizon HZ30E-10 Gas Fireplace...
Page 58
58 | Regency Horizon HZ30E-10 Gas Fireplace...
Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.