Table of Contents

Advertisement

Regency Horizon ™ HZ30E
Horizon HZ30E Product Video
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-880b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
Installer
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
: Please complete the details on the back cover
Installation Manual
MODELS:
www.regency-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you
cannot reach your gas
supplier, call the fi re department.
Owners &
HZ
30E
-NG Natural Gas
HZ
30E
-LP Propane
04/09/13

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZ30E-NG

  • Page 1 Regency Horizon ™ HZ30E Owners & Installation Manual Gas Fireplace MODELS: -NG Natural Gas -LP Propane www.regency-fi re.com Horizon HZ30E Product Video WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi...
  • Page 2 Title 24 CFR, Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH, in Canada. WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS Regency Horizon™ HZ30E Gas Fireplace...
  • Page 3 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The HZ30E has been designed to provide you with all the warmth and charm of a fi replace at the fl ick of a switch.
  • Page 4: Table Of Contents

    The Warranty: Limited Lifetime ........60 Vertical Terminations ...........29 Rigid Pipe 4" x 6-5/8" ...........29 Unit Installation with Horizontal Termination ....31 Unit Installation with Horizontal Termination ....32 unit installation with Vertical Termination .....33 High Elevation .............34 Gas Line Installation ............34 Regency Horizon HZ30E Gas Fireplace...
  • Page 5: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency Horizon HZ30E Gas Fireplace...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 7: Dimensions

    DIMENSIONS UNIT DIMENSIONS 30-9/16” (776mm) 14-1/2” (368mm) 14-1/4” (362mm) 28-11/16” (729mm) 1-1/2” (38mm) 27-5/8” (702mm) 24-7/8” (632mm) 5/8” (16mm) FACEPLATE AND DOOR FRAME DIMENSIONS 33-1/4” (845mm) 32-3/8” (822mm) 25” (635mm) 24-7/8” (631mm) 27-5/8” (702mm) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 8: Installation

    fi replace. 9) Wear gloves and safety glasses for protection while doing required maintenance. 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 9: Installation Checklist

    Flat on Wall Corner Recessed into Wall/Alcove 14) Final check. Corner Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 10: Clearances

    60" (1524mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) G: From Floor 21" (533mm) Top of Fireplace Opening Note: 0" No hearth required Installed Close to Floor Unit Alcove Regency Horizon™ HZ30E Gas Fireplace...
  • Page 11: Mantel Clearances

    13-1/4” To Unit 21” Base Top of Fireplace Opening MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 2”(51mm) MANTEL LEG Non-Combustible 1.5" (38mm) 5-1/2” (140mm) Allowable mantel leg projection 8” (203mm) 11” (279mm) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 12: Unit Assembly Prior To Installation

    3) Install any optional components with access panel removed. Screw Locations 4) Reinstall access panel with 2 screws - prior to installing any facing material Note: Access panel is no longer usable once facing material installed. Installation Access Panel Regency Horizon™ HZ30E Gas Fireplace...
  • Page 13: Framing Dimensions

    The nailing strips can be adjusted back up to 1-1/2” to allow for varying thicknesses in non-combustible material & wall fi nishes. Drywall or other facing Metal Stud (Header) Note: All other framing may Non-Combustible be of wood construction. Facing Metal Stud on edge Finished Floor Regency Horizon™ HZ30E Gas Fireplace...
  • Page 14: Framing & Finishing

    Important: 1/2" gap required between faceplate and fi nished wall when using part #316-924, 316-926, 316- 927 (4 pc. faceplate). When using part # 316-934, 316-936 and 316-937 (outer faceplate) the 1/2" gap is not necessary. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 15: Framing & Finishing

    0" (fl ush) Nailing Strip Flush w/unit Factory Set Unit NON-COMBUSTIBLE REQUIREMENTS Metal Stud (header) on edge 32-11/16" (830mm) Metal Stud Metal Stud Non-combustible Material 29-1/8” Non-combustible Material 6-1/4” 1-7/8” 1-7/8” 6-1/4” (159mm) (48mm) (48mm) (159mm) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 16: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Horizon™ HZ30E Gas Fireplace...
  • Page 17: 4" X 6-5/8" Rigid Pipe

    Offset Support 46DVA-ES (N/A - FPI) 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA Regency Horizon™ HZ30E Gas Fireplace...
  • Page 18 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 19: Vent Restrictor Position

    4) Once the vent restrictor plate is in the required position, secure with screws. SET 0 (Factory set) VENT RESTRICTOR AT 1-3/4”” 1-3/4” SET 1 THIS HOLE SETS THE VENT RESTRICTOR AT 1-1/4” 1-1/4” SET 2 THIS HOLE SETS THE VENT RESTRICTOR AT 3/4” 3/4” Regency Horizon™ HZ30E Gas Fireplace...
  • Page 20: Venting Introduction

    Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet.
  • Page 21: Horizontal Terminations

    S.S. screws #8 x 1-1/2” drill point Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency ® may be used for Flex installations 3) Horizontal vent must be supported every 3 feet.
  • Page 22: Horizontal Terminations

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent ® , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 23: Horizontal Terminations

    With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Please note the minimum centerline for basic install shown above. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 24 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 25 1 f o o t 6' Min. 5' Max. 10' Min. 8' Max. between 90 elbows 7' Min. 6' Max. 12' Min. 9' Max. is required. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 26: Venting Arrangement For Vertical Terminations

    Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set 2 if required. Vent Restrictor on Set 2 Vent Restrictor on Set 1 Regency Horizon™ HZ30E Gas Fireplace...
  • Page 27: Venting Arrangements - Vertical Terminations

    3/4” open Horizontal Distance (Feet) Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations when using two- 3" co-linear aluminium fl ex and 4 x 6-5/8" rigid pipe. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 28: Vertical Termination With Co-Linear Flex System

    46DVA-GK 3" Co-linear Adapter with fl ashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency Horizon™ HZ30E Gas Fireplace...
  • Page 29: Vertical Terminations

    5' Max. 5' Min. 1 foot between 90 required. elbows is required. 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. Restrictor Position - Set 0 (factory setting) Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 30 Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 31: Unit Installation With Horizontal Termination

    3 supplied screws (drilling pilot holes will make this easier). 4) Level the fi replace and fasten it to the framing using nails or screws through the top and side nailing strips. Diagram 7 Diagram 2 Diagram 1 Regency Horizon™ HZ30E Gas Fireplace...
  • Page 32: Unit Installation With Horizontal Termination

    fl ex pipe (10" (254mm) and slip it over the outer fl ue collar of the vent Outer Diameter) terminal at least 1-3/8"(35mm) and fasten with the 3 screws. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 33: Unit Installation With Vertical Termination

    Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 34: High Elevation

    6) When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 35: Wiring Diagram

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 36: Ac Power Adaptor Installation (For Surefi Re Systems)

    5) Neatly tuck any loose AC Power Adaptor wires neatly underneath / inside the appliance. Note: (keep wires away from the heat as much as possible). FCM - COM Regency Horizon™ HZ30E Gas Fireplace...
  • Page 37: Profl Ame Remote System Gtmf With Optional Fan

    CAUTION: Label all wires prior to disconnection Caution: Ensure that the wires do not touch any when servicing controls. Wiring errors can cause hot surfaces and are away from sharp edges. improper and dangerous operation. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 38: Optional Fan Wiring Diagram

    Caution: Ensure that the wires do not touch any is in ON position. hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 39: Optional Remote Control

    Large blue backlit LCD screen with temperature display. (Receiver comes with unit, not included with remote.) CAUTION CAUTION Do not wire millivolt Do not wire millivolt remote control wires wall switch wires to 120V wire. to 120V wire. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 40: Optional Wall Thermostat Installation

    Disconnect TH wire 3) Connect one thermostat lead to female connector, using male spade con- nector - see pic below. When complete turn remote receiver to the ON position. Unit will now operate using the wall thermostat. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 41: Wall Mount On / Off Switch And Receiver Installation

    1. GT remote installation - see Profl ame remote instructions for coding remote to receiver as well as operat- ing instructions. J-Box Receiver Slider Switch Wall Plate 12 pin connector - located on outer right side of the fi rebox. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 42: Gtmf Remote Installation

    Remove the 2 screws shown below at the bottom of the glass door b) Swing the door out 45 from the bottom and lift up and out. 6) Remove the burner by sliding it to the right - then lift out. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 43 11) See Profl ame remote instructions for coding remote to receiver as well as operating instructions. Note: HZ30E does not have BTU turndown, therefore this feature is inactive on the GTMF remote. 12) Reverse steps 10-1. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 44: Optional Fan Installation

    5) Remove the burner tray cover by lifting up and out as shown below. * Prior to removing burner - remove crystals, pebbles, spa stones and inner Location of screws on access plate panels - if installed. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 45 IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming the fan blades and housing using a soft brush nozzle. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 46: Refl Ective Panel Installation

    5) Reinstall glass door - reinstall faceplate. 3) Install the left side panel - secure in position with one panel clip and 6) Final installation one screw, as shown in the diagram below. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 47: Glass Crystals Or Optional Ceramic Stones

    Optional Ceramic Spa Stones shown on burner. For units P33S, P33SE, L676S, U32S, U32SE, E33S only For units P33S,P33SE L676S, U32S, U32SE, E33S only Glass Crystals shown on Burner and Firebox Floor For Units HZI390E HZI390EB HZI540EB only Regency Horizon™ HZ30E Gas Fireplace...
  • Page 48: Optional Pebble / Crystal Installation

    Natural River Pebbles shown surrounding the a Horizon Burner River Pebbles shown surrounding a Sunrise Burner Glass Crystals shown surrounding the Burner Regency Horizon™ HZ30E Gas Fireplace...
  • Page 49: Glass Door Installation

    3) Install cover plates over each screw with 2 magnets each as shown below. Magnet Cover Plate Diagram 4 Diagram 1 Hook top of door onto top flange Flush Door Cover Plates Installed Diagram 5 Diagram 2 Regency Horizon™ HZ30E Gas Fireplace...
  • Page 50: Pc. Faceplate Installation

    2) Lower the bottom of the faceplate gently - until it rests against the unit. Important: 1/2" gap required between faceplate and fi nished wall when using part #316-924, 316-926, 316- 927 (4 pc. faceplate). Regency Horizon™ HZ30E Gas Fireplace...
  • Page 51: Outer And Inner Door Frame Installation

    Inner door frame may be installed by itself, or with the outer door frame. The outer door frame cannot be installed by itself - if install- ing the outer door frame - the inner door frame must also be installed. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 52: Operating Instructions

    fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 53: Copy Of Lighting Plate Instructions

    If service is to be performed - you must disconnect power to the unit, from the battery pack, refer to manual. Appuyez sur le bouton ON / OFF Si le service est effectuée, vous devez débrancher l'appareil, du bloc-piles, voir le manuel d'instruction pour plus de détails. DO NOT REMOVE THIS INSTRUCTION PLATE 918-628b Regency Horizon™ HZ30 Gas Fireplace...
  • Page 54: Maintenance Instructions

    & reinstalled in accordance with the appliance with the glass panels manufacturer's instructions. removed, cracked or broken. 8) Verify operation after servicing. Replacement of the glass panels should be done by a licensed or qualifi ed service person. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 55: Valve Assembly Replacement

    5) Remove the burner tray cover by lifting up and out as shown below. * Prior to removing burner - remove crystals, pebbles, spa stones and inner panels - if installed. Location of screws on access plate Regency Horizon™ HZ30E Gas Fireplace...
  • Page 56 7) Partially lift out valve tray - use extreme caution, the thermodisc needs to be removed before valve tray is lifted out completely. Gas Line 8) Disconnect the inlet gas line and remove the valve assembly. 9) Replace valve assembly and reverse steps. Regency Horizon™ HZ30E Gas Fireplace...
  • Page 57: Main Assembly

    Wire (Valve to Burner ON/OFF) 911-006 Pilot Assembly - NG 918-880 Manual 911-007 Pilot Assembly - LP 316-064 Pilot Shield 904-641 Orifi ce # 50 (NG) 904-557 Orifi ce # 57 (LP) 316-917 Fan (optional) Regency Horizon™ HZ30E Gas Fireplace...
  • Page 58: Accessories

    Natural River Pebbles 316-946 Inner Door Frame Sunset Bronze 946-674 Ceramic Spa Stones 316-947 Inner Door Frame Stainless 316-951 Verona Glass Surround Pure Black 316-953 Verona Glass Surround Classic Grey 316-955 Verona Glass Surround Chocolate Brown Regency Horizon™ HZ30E Gas Fireplace...
  • Page 59: Warranty

    Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 60 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Horizon HZ30E Video Regency Horizon and SureFire are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2011 FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Horizon hz30e-lpHorizon hz30e

Table of Contents