Draining the Carburetor
1.
Turn OFF the engine. Let Cool. Turn the fuel valve ON.
2.
Position a container under the carburetor drain screw. Loosen the drain
screw.
3.
Allow fuel to drain completely drain and re-tighten the drain screw.
Note on Automatic Voltage Regulation (AVR)
Your generator is equipped with an Automatic Voltage Regulator which ensures a
constant voltage and present a waveform similar to what you get from the city power
grid. They are an improvement over basic generators but not as effective at safely
running sensitive electronics as our inverter generators, which can produce almost
perfect sine waveforms.
Therefore powering some sensitive electronics with this generator is not recommended,
since it will risk damage the electrical componentry and can cause a risk of damage.