1. Rotate the fuel valve lever to ON position (Vertical
position).
This is located on the left side of your generator, it is
attached to the bottom of the fuel tank.
2. If the engine is cold: push the choke lever into the
CLOSED position.
You can find the choke lever above the air filter cap
on the left side of your generator.
3. Disconnect all devices from the outlets on the
generator panel. Then press the engine switch to the
RUN position.
4. Grasp the recoil stater handle and pull it until the
generator starts.
Do not allow the recoil starter to snap back. Re-
turn it slowly by hand.
5. Push the choke lever to the OPEN position as the
engine warms up. The choke is used to provide the
proper air-fuel mixture when the engine is cold.