Superior MHW36R Installation And Operation Instructions Manual page 16

Clean-face round back fireplace with bi-fold doors and combustion air kit
Table of Contents

Advertisement

OPERATION AND MAINTENANCE GUIDELINES
Continued
Door Removal
1. Fold doors (fully open) and press up on upper door spring clip until
top pin is free of the spring clip (see Figure 28). Tip door toward
middle of fireplace opening and lift door out of the lower pivot hole.
2. Repeat step 1 for remaining door.
Fold Door and
Slide Top Pins
Into Track
Figure 28 - Removing / Installing Bi-Fold Doors
Installing Glass Doors
1. With bi-fold doors completely folded, insert bottom pivot pin into pivot
hole located near bottom corner of front face opening and swing door
to vertical position making sure top pins slide into door track. Door is
installed when top door pin snaps into spring clip (see Figure 28).
2. Repeat step 1 for remaining door.
If you find the doors do not close properly or do not appear level or
straight, proceed with section on door adjustment.
Door Adjustment
Remove doors and slightly loosen lower pivot clips and upper spring
clips. Replace doors and fully close them. Use 1/8" shims (any material)
to level doors. Once proper setting is achieved, carefully open doors
enough so that you can access spring clips with a phillips screwdriver.
Tighten screws. See Figure 29.
16
Spring Clip
Insert Pin into
Figure 29 - Adjusting Bi-Fold Doors
Spring Clip
CLEANING GLASS
Clean the glass with any commercial glass cleaner or soap and water.
Do not use any abrasive material to clean glass. Do not clean glass with
Insert Bottom
any cool water if glass is still hot from fire and smoke.
Pivot Pin into
Hole
DAMPER OPERATION
Pivot Hole
The damper handle, which opens and closes damper blade, is located
inside firebox at center towards back wall. Pushing handle back in keyway
slot will free damper blade to automatically open. To close, reach in and
push handle back into keyhole slot then pull down and forward to lock it
in place (see Figure 30). Damper is not designed to be airtight. A small
gap around damper blade is normal.
Figure 30 - Damper Operation
Risk of fire! Always replace grate with IHP part
number 11116 grate only. This grate has been
designed to keep the operation of your fireplace
safe and efficient.
SuperiorFireplaces.US.com
Damper
Weight
Closed Damper
WARNING
Damper
Handle
Open Damper
127312-01D