Superior MULTI-OPEN SERIES Installation Instructions Manual

Direct vent multi-open series
Hide thumbs Also See for MULTI-OPEN SERIES:

Advertisement

This appliance may be installed in an aftermar-
ket permanently located, manufactured home
(USA only) or mobile home, where not prohib-
ited by local codes. This appliance is only for
use with the type of gas indicated on the rating
plate. This appliance is not convertible for use
with other gases, unless a certified kit is used.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
A French manual is available upon request. Order Form Number
700,001CF.
Ce manuel d'installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 700,001CF.
WH Report No. J20006712
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INSTALLATION
INSTRUCTIONS

DIRECT VENT

MULTI-OPEN SERIES
VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS
P/N 700,001M REV. H 09/2005
MODELS
M
i
i l l
o v
t l
M
o
e d
C
D
S
T
C -
M
N
C
D
C
L
C
D
S
T
C -
M
P
C
D
C
L
C
D
P
F
C -
M
N
C
D
C
R
C
D
P
F
C -
M
P
C
D
C
R
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
s l
l E
c e
r t
n o
c i
M
C -
M
N
C
D
S
T
C -
E
N
C
D
C -
M
P
C
D
S
T
C -
E
P
C
D
C -
M
N
C
D
P
F
C -
E
N
C
D
C -
M
P
C
D
P
F
C -
E
P
C
D
o
e d
s l
C
L
C -
E
N
C
L
C -
E
P
C
R
C -
E
N
C
R
C -
E
P
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MULTI-OPEN SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Superior MULTI-OPEN SERIES

  • Page 1: Direct Vent

    INSTALLATION INSTRUCTIONS DIRECT VENT MULTI-OPEN SERIES This appliance may be installed in an aftermar- ket permanently located, manufactured home VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS P/N 700,001M REV. H 09/2005 (USA only) or mobile home, where not prohib- ited by local codes.
  • Page 2: Table Of Contents

    PACKAGING GENERAL INFORMATION TABLE OF CONTENTS The assembled vented gas fireplace heater is Packaging ........page 2 packaged with: Note: Installation and repair should be per- formed by a qualified service person. The appli- Introduction ........page 2 1 - one cartoned log set located in firebox area; ance should be inspected annually by a quali- General Information ......
  • Page 3: Location

    Electronic Models - This appliance may be installed in an af- WARNING: FAILURE TO COMPLY WITH Electronic models have a fixed rate gas valve. termarket permanently located, manufac- THE INSTALLATION AND OPERATING IN- Input of electronic models is shown in the tured home (USA only) or mobile home, STRUCTIONS PROVIDED IN THIS DOCU- following table:...
  • Page 4: Appliance And Vent Clearances

    Corner - Left Corner - Right (CDCL) (CDCR) See-Through (CDST) VERTICAL VENT HORIZONTAL VENT HORIZONTAL VENT Peninsula - TOP - REAR (CDPF) See-Through one side flush with a wall (CDST) - TYPICAL LOCATIONS Figure 2 The appliance should be mounted on a fully supported base extending the full width and depth of the unit.
  • Page 5: Typical Installation Sequence

    All framing details must allow for a mini- TYPICAL INSTALLATION SEQUENCE 3 - Lift the pressure relief plates and remove mum clearance to combustible framing the cardboard from underneath each of them. members as shown in Table 2 on page 4 . The typical sequence of installation follows, however, each installation is unique resulting in 4 - Open the control compartment access panel...
  • Page 6 EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9” in U.S. = 12” in Canada Detail D 3 ft.
  • Page 7 FIREPLACE FRAMING SPECIFICATIONS inches (millimeters) inches (millimeters) CDPF (Peninsula) CDST Minimum Framing (See-Through) Minimum Framing Stud Size is 2x4 Stud Size is 2x4 (267) VENT FRAMING - (267) VENT FRAMING - TOP VENT WITH TOP VENT WITH ONE 90º ELBOW ONE 90º...
  • Page 8: Fireplace Specifications

    FIREPLACE SPECIFICATIONS FINISH WALL BRACKET CDST (See-Through) (Front and back edge of unit top) (254) 12 (305) FRAMING SPACERS (13) NOTE - Unit has a factory-installed (Top and Both Sides) vent sea cap and vent cover plate (see Figures 17 and 18 on page 10) FLUE in each flue outlet.
  • Page 9 FIREPLACE SPECIFICATIONS CONTINUED CDCL (Corner-Left) OPTIONAL GAS INLET (235) FRAMING SPACERS (254) (Top, Side and Back) NOTE - Unit has a factory-installed vent seal cap and vent cover plate (see Figures 17 and 18 on page 10) FLUE in each flue outlet. The vent seal cap (305) (Top or Side) is not shown in this figure.
  • Page 10: Step 2. Routing Gas Line

    Step 2. ROUTING GAS LINE When the top vent collar is being used, from Preparing the Appliance Top or Rear Vent inside the firebox, loosen the two screws in the Outlet when vertically terminating the vent Route a " (13 mm) gas line as shown in Figure keyhole slots of the cover plate and remove the system above the roof 9 (CDST), 10 (CDPF), 11 (CDCL) or 12 (CDCR)
  • Page 11: Vertical Termination Systems

    VERTICAL TERMINATION SYSTEMS (ROOF) i t c i t c Figure 21, and Figures 32 through 36 on i t c pages 14 and 15 and their associated Vertical i t c Vent Tables illustrate the vertical venting con- figurations that are allowed to be used with these appliances.
  • Page 12 The dimpled end of the vent components fit over Vertical (Offset) Installation This seating position is indicated by the align- the appliance collar to create the positive twist ment of the arrow and dimple as shown in Analyze the vent routing and determine the lock connection.
  • Page 13 Use a carpenter’s level to measure from a J. Install the storm collar - Install the storm collar, supplied with the flashing, over the vent/ constant surface and adjust the support straps flashing joint. See Figure 30. Loosen the storm as necessary.
  • Page 14: Vertical Vent Tables And Figures

    VERTICAL VENT FIGURES/TABLES *Ceiling Note: Secure Vent (rigid vent pipe) is shown Firestop/Spacer in the figures; Secure Flex (flexible vent pipe) (SV4.5VF) may also be used (see page 21). **Wall WARNING: UNDER NO CIRCUM- Firestop/Spacer (SV4.5HF) STANCES MAY SEPARATE SECTIONS OF CONCENTRIC FLEXIBLE VENT PIPE BE JOINED TOGETHER.
  • Page 15 VERTICAL VENT FIGURES/TABLES (continued) *Ceiling Firestop/Spacer (SV4.5VF) A Vent Restrictor, as shown in Figure 20, page 10, may be used in this application **Wall Firestop/Spacer (SV4.5HF) **Wall *Ceiling Firestop/Spacer Firestop/Spacer (SV4.5HF) (SV4.5VF) Figure 35 - Rear Vent - THREE ELBOWS *Ceiling **Wall Firestop/Spacer...
  • Page 16: Horizontal Termination System

    HORIZONTAL (OUTSIDE WALL) TYPICAL HORIZONTAL VENT INSTALLATION TERMINATION SYSTEM Support Building Horizontal / Inclined Run Brackets Figure 37, and Figures 40 to 46 on page 18 to Support SV4.5 HT Framing Termination 20 and their associated Horizontal Vent Table illustrate the horizontal venting configurations SV4.5E90 Elbow that are allowed to be used with these appliances.
  • Page 17 J. Assemble vent run to exterior wall - If not previously measured, locate the center of the Firestop/Spacer (SV4.5HF) shown on the exterior side of the wall. It vent at the exterior wall. Prepare an opening as may also be installed on the interior side.
  • Page 18: Horizontal Vent Tables And Figures

    HORIZONTAL VENT FIGURES/TABLES Note: Secure Vent components (rigid vent pipe and terminal) are shown in the figures; Secure Flex components (flexible vent pipe and terminal) may also be used. Note: Two 45 degree elbows may be used in place of one 90 degree elbow. The same rise to run ratios, as shown in the venting figures for 90 elbows, must be followed if 45 degree elbows are used.
  • Page 19 HORIZONTAL VENT FIGURES/TABLES (continued) **Wall Firestop/Spacer (SV4.5HF) *Ceiling Firestop/Spacer (SV4.5VF) **Wall Firestop/Spacer (SV4.5HF) See Table 3 as an aid in venting component selection for a particular range of exterior wall thicknesses. Square termination (SV4.5HT) shown. Figure 43 - Rear Vent - TWO 90 DEGREE ELBOWS **Wall Firestop/Spacer (SV4.5HF) H + H...
  • Page 20 HORIZONTAL VENT FIGURES/TABLES (continued) **Wall Firestop/Spacer (SV4.5HF) **Wall Firestop/Spacer (SV4.5HF) *Ceiling Firestop/Spacer (SV4.5VF) See Table 3 as an aid in venting component selection for a particular range of exterior wall thicknesses. Square termination (SV4.5HT) shown. Figure 45 - Rear Vent - THREE 90 DEGREE ELBOWS *Ceiling Firestop/spacer (SV4.5VF) **Wall...
  • Page 21: Venting Using Flexible Vent Pipe

    VERTICAL OR HORIZONTAL VENTING USING SECURE FLEX KITS AND COMPONENTS FLEX VENT NOTE: OUTER PIPE IS PULLED AWAY TO SHOW THE DETAIL OF THE INNER PIPE Secure Flex venting kits and components may be SECURING SCREW used in any venting application in place of rigid (3 PLACES EQUIDISTANT JUST BELOW GEAR CLAMP) Secure Vent (SV4.5) direct vent components.
  • Page 22: Step 4. Field Wiring

    Step 4. FIELD WIRING 2. Open the control compartment access panel by 10. After wiring is complete, reinstall the outlet actuating the spring-loaded magnetic catches se- receptacle, junction box/outlet receptacle as- Refer to Section A for millivolt appliances and curing the panel, gently depressing the outer top sembly;...
  • Page 23: Step 6. Connecting Gas Line

    Step 7. INSTALLING LOG SET, VERMICU- Electronic Wiring Diagram (Honeywell) Gas Flex Line Connector LITE AND CERAMIC FIBER CHUNKS Showing the Blower Wiring for the Optional " NPT x " x " Flare Flare Fitting Shut-Off Valve Valve FBK-250 Kits The log set, a bag of decorative volcanic stone 1.
  • Page 24: Step 9. Installing Glass Enclosure Panels

    Electronic Appliance Checkout Allow the burner to operate for at least 15 WARNING: HANDLE THE GLASS WITH EX- minutes. Observe the flame continuously. If it TREME CARE! TEMPERED GLASS IS SUS- To light the burner, turn ‘ON’ the the wall- appears weak or sooty as previously described, CEPTIBLE TO DAMAGE (SCRATCHES, FOR mounted ON/OFF switch or the thermostat...
  • Page 25: Step 11. Hood Installation

    Step 11. HOOD INSTALLATION Combustible materials may project beyond the Note: Combustible wall finish materials and/ sides of the fireplace opening as long as they or surround materials must not be allowed to All of these appliances must have hoods are kept within the shaded areas illustrated in encroach the area defined by the appliance Figure 61 .
  • Page 26: Installation Accessories

    INSTALLATION ACCESSORIES t s i ™ t s i ™ z i r l a t i t a i t a t i k r i f , r e . r e h t i e r i z i r l a t i t a...
  • Page 27 GAS CONVERSION KITS WARNING: THIS CONVERSION KIT SHALL BE AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION INSTALLED BY A QUALIFIED SERVICE AGENCY IN SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SER- ACCORDANCE WITH THE MANUFACTURER'S IN- VICE CONFORMÉMENT AUX INSTRUCTIONS DU STRUCTIONS AND ALL APPLICABLE CODES AND FABRICANT ET TOUTES EXIGENCES ET CODES REQUIREMENTS OF THE AUTHORITY HAVING JU- APPLICABLES DE L'AUTORISÉS AVOIR LA JURIDICTION.
  • Page 28: Gas Conversion Kits

    Remove the screw securing the pilot assembly i f i to its mounting bracket. Back off the flare nut at the end of the pilot gas line to free the pilot assembly from the gas line. Remove the pilot orifice and replace it with the one provided with the conversion kit.

Table of Contents