Superior MHW36R Installation And Operation Instructions Manual page 12

Clean-face round back fireplace with bi-fold doors and combustion air kit
Table of Contents

Advertisement

VENTING INSTALLATION
Continued
Storm Collar Installation (SC1)
Place storm collar over pipe and slide down until it is snug against the
open edge of flashing (see Figure 19). Use SC1 for all round terminations.
NOTE: Storm collar is required but can be installed after the home is sited.
Chimney
Pipe
Storm
Collar
Figure 19 - Storm Collar
Terminations/Spark Arrestor
Fireplace system must be terminated with listed round top termination. In any case,
refer to installation instructions supplied with termination. Terminations approved
for this fireplace are RT-8DM and RTL-8DM. Figure 20 shows an RTL-8DM round
top termination.
IMPORTANT: Terminations are required but can be installed once the manufactured
house is sited.
Do not seal openings on the rooftop flashing. Follow
the installation instructions provided with the ter-
mination being used.
Terminations with 16" slip pipe sections are available. The RTT-8DM and
RTTL-8DM are approved for flashing installations. When needed, these
adjustable terminations may be used in combination with the pipe assembly
to achieve correct chimney height.
NOTE: In the rare instance there is a problem with side driven rain or wind,
or the chimney is not drafting properly, an ADS-8DM Anti Draft Shield can
be used with round terminations.
12
Waterproof
Caulk
Flashing
CAUTION
SuperiorFireplaces.US.com
Attach Bracket Tabs
to Outer Pipe (3
Places) Secure with
Screws
Overlap Shingles
Top and Sides
Figure 20 - Termination
CHASE INSTALLATIONS
Instructions for chase installations are included with chase style termination
chosen. In a multiple chase installation, be sure to provide adequate distance
between terminations to prevent smoke spillage from one termination to another.
We suggest that terminations be separated at least 24", center to center and stacked
at a vertical height difference of 18" (see Figure 21).
24" Min.
24" Min.
Figure 21 - Multiple Chase Installation
RTL-8DM
Level of Flue Gas
Outlet
Caulk
Storm
Collar
Flashing
Underlap Shingles
Bottom Only
18"
Min.
Typ.
127312-01D