A p p e n d i x C :
U L L i s t e d G r a d e A C o n t r o l U n i t R e q u i r e m e n t s
Table2: Contact ID Zone Alarm/Resto-
ral Event Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals
when using the standard (non-automatic) Contact ID
reporting format.
Medical Alarms
(1)AA Medical
(1)A1 Pendant Transmitter
(1)A2 Fail to Report In
Fire Alarms
(1)1A Fire Alarm
(1)11 Smoke
(1)12 Combustion
(1)13 Water Flow
(1)14 Heat
(1)15 Pull Station
(1)16 Duct
(1)17 Flame
(1)18 Near Alarm
Panic Alarms
(1)2A Panic
(1)21 Duress
(1)22 Silent
(1)23 Audible
Burglar Alarms
(1)3A Burglary
(1)31 Perimeter
(1)32 Interior
(1)33 24 Hour
A p p e n d i x C : U L L i s t e d G r a d e A
C o n t r o l U n i t R e q u i r e m e n t s
• Installer should verify communication format
between control unit and receiver.
• Entry delay must not exceed 45 seconds.
• Exit delay must not exceed 60 seconds.
• Minimum bell cutoff time is 4 minutes.
• Keyswitch (if used) must be mounted in a pro-
tected area.
• 'Quick Exit' feature must be disabled.
• 'Bell Squawk on Trouble' feature must be enabled.
• Minimum 'Dialing Attempt' must be 5 and maxi-
mum 10.
• Hardwired zones must be EOL configuration.
• 'Code Required to Bypass Zones' must be enabled.
• 'Bypass Status not Displayed While Armed' option
selected.
NOTE:
This control unit is to be checked by a qualified technician at least once every 3 years.
5 4
(1)34 Entry / Exit
(1)35 Day / Night
(1)36 Outdoor
(1)37 Tamper
(1)38 Near Alarm
General Alarms
(1)4A General Alarm
(1)43 Exp. module failure
(1)44 Sensor tamper
(1)45 Module Tamper
(1)4A Cross Zone Police Code
24 Hour Non-Burglary
(1)5A 24 Hour non-Burg
(1)51 Gas detected
(1)52 Refrigeration
(1)53 Loss of Heat
(1)54 Water Leakage
(1)55 Foil Break
(1)56 Day Trouble
(1)57 Low bottled Gas level
(1)58 High Temp
(1)59 Low Temp
(1)61 Loss of Air Flow
Table 3: SIA Format Automatic
Zone Alarm/Restoral Codes
Zone Definition
Delay, Instant, Interior, Delay
Stay/Away, Interior Stay/Away,
24-hr Burg.
24-hr Fire
24-hr Supervisory Buzzer
24-hr Sprinkler
24-hr Gas
24-hr Heat
24-hr Medical
24-hr Emergency (non-medical)
24-hr Waterflow
24-hr Freeze
24-hr Holdup
24-hr Panic
Latching 24-hr
• 'Test Transmission Cycle' must be set for daily
transmission.
• 'Keypad Lockout' must be programmed.
• 'Temporal Three Fire Signal' must be enabled.
• 'Closing Confirmation' must be enabled.
• 'UL Communications Priority' must be enabled.
• 'One time 1-hour User Enabled DLS Window' must
be enabled.
• 'Answering Machine/Double Call' option must
NOT be enabled.
• 'Wireless Supervisory Window' must be pro-
grammed 4 hours or less.
• 'RF Jamming Detection Zone' must be pro-
grammed; zone type 'Instant'.
SIA Auto Rep
Codes*
Zone Alm/Rest.
BA-ZZ/BH-ZZ
FA-ZZ/FH-ZZ
UA-ZZ/UH-ZZ
SA-ZZ/SH-ZZ
GA-ZZ/GH-ZZ
KA-ZZ/KH-ZZ
MA-ZZ/MH-ZZ
QA-ZZ/QH-ZZ
WA-ZZ/WH-ZZ
ZA-ZZ/ZH-ZZ
HA-ZZ/HH-ZZ
PA-ZZ/PH-ZZ
BA-ZZ/BH-ZZ
* ZZ = zones 01-32