Baxi LINA 3 COMFORT HT Instruction Manual page 53

Condensing gas wall-hung boilers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 44
The shower function optimises DHW control, for example, when someone is taking a shower.
The function delivers DHW at a lower than rated temperature.
To modify the maximum temperature of the shower function, proceed as described in section 4.3.
This function can be manually enabled as follows:
• Press one of the two buttons
(SHOWR appears on the display for a few seconds followed by HW SS);
• press OK while the delivery temperature and the symbol
• the function lasts 60 minutes (the symbol
At the end of this period, DHW temperature returns to that of the operating mode set before the function activated
(the symbol
not longer flashes on the display).
N.B.:
to disable the function before the 60 minute period terminates, proceed as follows:
• press one of the two buttons
• the display visualises the message "HWSS" and then "OFF".
4.3 CHANGE TEMPERATURE VALUES OF THE FUNCTIONS ASSOCIATED WITH THE BUTTON
To change the temperature value, proceed as follows:
• Press IP to enable the PROG function;
• press
to scroll the functions to modify, as described in the following table:
Function
Visualizzazione
The set temperature
COMFR
flashes
(factory value = 20°C)
The set temperature
ECONM
flashes
(factory value = 18°C)
The set temperature
NOFRS
flashes
(factory value = 5 °C)
The set temperature
SHOWR
flashes
(factory value = 40°C)
• To change the value of the selected function, press
• To exit, press IP
4.4.1 TIMED SHUTDOWN OFF (HOLIDAY PROGRAMME)
This function allows you to disable hourly programming (section 3.6) for a certain period of time. During this time, mini-
mum ambient temperature is assured (factory setting 5°C). This setting may be modified as described in section 4.3 under
"NOFRS".
To enable the function, proceed as follows:
• press
and set the "AUTO" function (symbol
• press , MM 60 appears on the display and the symbols
INSTRUCTIONS FOR USERS
4.2 SHOWER FUNCTION
+/-
and then
to enable the function
flashes during this time).
+/-
and then
;
Description of function
Boiler in heating mode at rated temperature.
Boiler in heating mode at reduced temperature.
Boiler in heating mode at preset antifreeze ambient temperature.
Boiler in DHW mode at the preset temperature.
+/-
4.4 TIMER FUNCTIONS (BUTTON )
);
flashes on the display;
;
flash.
53
926.420.3 - EN

Hide quick links: