Jet 505710 Operations & Parts Manual page 10

Orbital (jitterbug) sander
Table of Contents

Advertisement

Troubleshooting JAT-710 Orbital (Jittebug) Sander
Any disassembly of the tool should be done by qualified service personnel. For problems not addressed
below, contact JET technical service at 800-274-6846.
Problem
Tool will not start.
Starts immediately when
air is connected without
throttle lever being
pressed.
Excessive or abnormal
vibration.
Loss of power; erratic
action.
Excessive heat develops
in tool.
Severe air leakage.
(Note: Minimal escape of
air is often normal for air
tools.)
10
JAT-710 Orbital (Jitterbug) Sander
 
Possible cause
Air valve closed or obstructed.
Dirt or gum deposits on
components.
Rotor vanes or other components
are worn.
Lever inoperable.
Bearing(s) worn.
Operating lever malfunction.
Bearing(s) worn.
Low air pressure.
Moisture or obstruction in air
hose.
Improper size of air transmission
lines, hoses, fittings, or
couplings.
Dirt or gum deposits on
components.
Rotor vanes are worn.
Insufficient lubrication.
Worn components.
Air valve obstructed or damaged.
Housing loose or damaged.
Remedy
Open valve; clear any obstructions.
Flush tool with gum solvent.
If problem persists, disassemble,
clean and lubricate internal parts.
Replace worn components.
(Replace vanes as an entire set.)
Clean lever mechanism to ensure
free movement. Replace
mechanism if needed.
Disassemble and inspect bearing.
Grease or replace as needed.
Clean operating lever mechanism
to ensure free movement. Replace
mechanism if needed.
Disassemble and inspect bearing.
Grease or replace as needed.
Verify compressor has proper CFM
rating for tool.
Check compressor regulator
setting; set air pressure to 90 psi.
Set regulator dial on tool to
maximum setting.
Check for loose connections.
Air supply must be clean and dry.
Clean out air hose(s) and remove
any kinks or bends.
Use appropriate-sized air
lines/hoses.
Verify proper fittings/couplings.
Flush tool with gum solvent.
Check and clean air filter on
compressor.
Clean external areas of tool. If
problem persists, disassemble,
clean and lubricate internal parts.
Replace vanes (entire set).
Lubricate with air tool oil.
Replace components as needed.
Clean or replace.
Tighten or replace as needed.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jat-710

Table of Contents