The MAC Viper Wash gives service and maintenance information by displaying a large 3- or 4-character
short code and a smaller full-text message in the fixture's display. The short code is visible at a distance,
allowing easier reading with the fixture still in the rig, for example, while the full-text message gives more
detailed information.

Warning messages

Warning messages indicate that either:
• problems might appear in the future if no action is taken, or
• the user needs to pay special attention to a function or procedure when working with the fixture.
The MAC Viper Wash communicates warnings as follows:
• Warning codes are shown continuously in the display and disappear when the user reacts to the warning.
• If more than one warning is detected, all warnings are displayed in sequence.
• If the display is inactive, the fixture's status LED (see Figure 2 on page 8) flashes orange to indicate that
there is a warning. Activating the display will show the warning.
• Messages regarding the internal barndoors, iris and color wheel will only be shown if an IBD module is
installed.
The possible warning messages are listed in Table 3 below
Short code
BANK
BATW
BONA
CMTW
DINA
EFTW
HOT
INLK
NFWR
PANA
PTTW
PUTW
26
Long message and explanation
BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
BAL TEMP HIGH
Ballast PCB sensor detects that normal operating temperature is exceeded.**
BARNDOOR NOT ADJUSTED
No internal barndoors adjustment data in EEPROM. Barndoors may be incorrectly adjusted.*
CMY TEMP HIGH
CMY PCB sensor detects that normal operating temperature is exceeded.**
DIMMER ADJUST
No dimmer adjustment data in EEPROM. Dimmer may be incorrectly adjusted*.
EFF TEMP HIGH
Effects PCB sensor detects that normal operating temperature is exceeded.**
LAMP HOT
Lamp is too hot to restrike. Pan and tilt are disabled for 8 minutes to reduce the risk of falling
fragments if the lamp has exploded. Fixture will attempt to restrike at one-minute intervals. If
lamp still refuses to strike after eight attempts, an LAER (Lamp Error) message is displayed.
INVALID LICENSE KEY
Invalid license key entered. Warning is displayed and it is impossible to enter a license key for
10 seconds.
NEW FW REQUIRED
Fixture has detected a software problem and is requesting new firmware. There may be some
loss of fixture functionality.
PAN ADJUST
No pan adjustment data in EEPROM. Pan may be incorrectly adjusted.*
PT TEMP HIGH
Pan/tilt PCB sensor detects that normal operating temperature is exceeded.**
PSU TEMP HIGH
Power supply unit PCB sensor detects that normal operating temperature is exceeded.**
Table 3: Warning messages