Venting Installation; Installation Precautions; Venting Requirements - Vermont Castings VLI31DVNTSC Installation And Operating Instructions Manual

Vlidv series direct vent gas fireplace insert
Table of Contents

Advertisement

VLI31 Fireplace Insert
Read all instructions completely and
thoroughly before attempting installation.
Failure to do so could result in serious injury,
property damage or loss of life. Operation
of improperly installed and maintained
venting system could result in serious injury,
property damage or loss of life.
Failure to follow these instructions will void
the warranty.

INStALLAtION PRecAutIONS

Consult local building codes before beginning the installa-
tion. The installer must make sure to select the proper vent
system for installation. Before installing vent kit, the installer
must read this insert manual and vent kit instructions.
Only a qualified installer/service person should install vent-
ing system. The installer must follow these safety rules:
Wear gloves and safety glasses for protection.
Use extreme caution when using ladders or when
on rooftops.
Be aware of electrical wiring locations in walls and
ceiling.
The following actions will void the warranty on your vent-
ing system:
Installation of any damaged venting component.
Unauthorized modification of the venting system.
Installation of any component part not manufactured
or approved by Vermont Castings Group.
Installation other than permitted by these instruc-
tions.
this insert must be vented to the outside.
the venting system must NeVeR be attached
to a chimney serving a separate solid fuel
burning appliance. each gas appliance must
use a separate vent system. Do not use
common vent systems.
10

VeNtING RequIReMeNtS

Make sure the exhaust pipe on heater
connects to exhaust portion of cap. At-
tach flex liners. Figure 6
Do not crimp or rupture liner when bend-
ing it into chimney offsets.
The exhaust vent must reline the entire length of
chimney and terminate above chimney top.
Vent must meet all vent manufacturer's requirements
when installed.
Make sure you have the following before installing
unit:
3" and 3" UL 1777 Listed gas liner for air inlet and
exhaust.
Vertical Terminations kits: HEDV3T11,
HEDVRT, AI31TK33A
Inlet
Figure 6 -
Venting Unit
FP1922
vent requirements

VeNtING INStALLAtION

Exhaust
Maximum Height 40'
(1.9 m)
Minimum Height 10'
(3 m)
FP19
83D4009