VLI31 Fireplace Insert
Max
300 Watts
Max
300 Watts
A/C Module
NOte: Wall switch wires must
be connected together if a wall
switch is not being used.
Figure 15 -
Signature Command Wiring Diagram
electrical connections should only be
performed by a qualified, licensed electrician.
Main power supply must be turned off before
connecting fans to the main electrical power
supply or performing service.
18
A/C Module
To Outlet
Optional Aux.
300 Watts
Control Board
Conversion
NG/LP
Ground
Plug-in Connector
Control Board to
Solenoid
Gas In
FP2679
SCS wiring diagram
Plug-in Connector
Control Board to Command Center
OFF/LO
Plug-in Connector
Command Center
Stepper Motor to
Control Board
DC Power/Green
Valve
eLectRIcAL INStALLAtION
Pilot
RF Receiver
ON/OFF Button
Black / Thermopile
Red / Thermopile
Sensor
Ignitor / Sparker
LED
ON/HI
Master Switch
Gas Out
Pilot Gas Tubing