GeNeRAL INStALLAtION INFORMAtION

BeFORe yOu StARt

Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that all
listed parts have been received.
The following factors should be taken into consideration:
This insert should have sufficient access for its safe
operation and maintenance.
The flow of combustion and ventilation air must not be
obstructed.
Minimum clearances to combustibles, such as mantels,
must be maintained. Refer to Pages 8 and 9, Figures 3
and 4.
Never obstruct the front opening of the insert.
Do not install in the vicinity where gasoline or other
flammable liquids may be stored.
These units can be installed in a bedroom. Refer to
National Fuel Gas Code ANSI Z33.1/NFPA 54 (current
edition), the Uniform Mechanical Code (current edi-
tion), and Local Building Codes for specific installation
requirements.
IMPORtANt: your direct vent insert was designed to
be installed in an existing wood burning fireplace. the
location and clearances are subject to local building
codes.
83D4009

INSeRt APPLIcAtIONS

Before installing the gas fireplace insert, consider the
functioning needs of the fireplace. Confirm the size of the
fireplace cavity, the design of the chimney, and the avail-
ability of the gas supply and electricity.
IMPORtANt: your direct vent insert is designed to
be only vented vertically with a minimum height of
10 feet.
When the unit is installed into a wood burning fireplace,
the minimum distance the mantel can be placed above the
fireplace is governed by local building codes applicable to
wood burning fireplaces. Consult local authorities having
jurisdiction for these clearances. The underside of the
mantel will become warm. Use only finishes which are heat
resistant and do not discolor.
cLeARANceS
MINIMuM FIRePLAce SIZe/cLeARANceS
tO cOMBuStIBLeS
The dimensions shown on Pages 8 and 9,
Figures 3 and 4, are minimum clearances to
maintain when installing this heater. Follow
these instructions carefully to ensure safe
installation. Failure to follow instructions exactly
can create a fire hazard.