Brew Unit - Manual Reset To "Home Position" (Brew Unit Not Installed) - Miele CVA610 Technical Information

Table of Contents

Advertisement

Technical Information
5.29
Brew Unit – Manual Reset to "Home Position"
Brew Unit not installed in appliance)
(
Refer to figure 5-26
3. Press on the latch A; and press the funnel down B.
4. Push the connection piece to the far left position C.
5. Press "PRESS" once.
Figure 5-26: Moving the brew unit to home position.
6. The "home" position (Figure 27) after resetting the Brew Unit.
The Brew Unit can now be reinstalled into the appliance.
Figure 5-27: Brew unit in reset position
.
66
CVA610 Coffee System

Advertisement

Table of Contents
loading

Table of Contents