CVA610 Coffee System
Technical Information
Should the grinder cone become blocked, the Balls get pressed into
the Mounting (as shown below in figure 4-14, Item C) resulting in
the drive force being interrupted.
A Normal operation
B Overload protection activated
C Force transfer interrupted
Figure 4-14: Grinder cone ball positions under various operating conditions.
27