5.20
Hot Water Valve (Y12) – Removal
Refer to figure 5-18.
1. Open the door.
2. Remove the Rear Door Panel and Fascia Panel Cover
(5.12 & 5.13).
3. Disconnect the connections from the hot water valve (Item 7).
4. Loosen the hot water valve nuts.
5. Pull out the hot water valve from the connector (Item 6).
5.21

Coffee Temperature - Check

1. Set the grinding grade to medium.
2. Set the coffee quantity to medium.
3. Set the coffee (medium size) temperature to medium (standard
setting).
4. Set the number of pulses for the flow meter for 1 coffee to 350
(standard setting), see — . Diagnosis mode.
5. Prepare 3 coffees (medium size) one after the other.
6. When the fourth coffee is being dispensed, hold the sensor
probe directly in the flow of coffee.
If the temperature at the coffee dispenser is 171
unit is in order.
5.22
Brew Unit — Removal (in start/home position)
1. Open the door.
2. Remove the grounds container.
3. Hold the handle and press on the part marked PRESS.
4. Remove the percolator from the unit.