Kitchen or Internal Space Air Supply
The appliance can only be installed in a room which meets ventilation regulations in force but
in any event the room must have a permanent vent of minimum free air of of 36cm
Installation pipes should be fitted in accordance with current Gas Regulations. Pipework from
the meter to the cooker must be of adequate size, cooker connection size of 15mm Dia. On
completion test the gas installation for tightness and purge in accordance with the regulations
in force.
A metal plate (with square holes) which is provided in the Aga pack MUST be positioned on the
top runners of the Baking Oven. Slide the plate in fully, until it makes contact with the back of
the oven.
This baffle is a permanent part of the Baking Oven, to regulate the oven temperature.
A 3 Amp 230V~50Hz fused electrical supply is required adjacent to the appliance. External
wiring to the fan unit must be installed using a 3-core heat resistant 85ÞC PVC sheathed cable
and in accordance with the current Wiring Regulations and any local regulations which apply.
The wiring should be completed as indicated:
The method of connection to the mains electricity supply must facilitate complete electrical
isolation of the appliance, preferably by the use of an unswitched shuttered socket outlet in
conjunction with a fuse three pin plug. Alternatively, a fused double pole switch, having a
contact separation of at least 3mm in both poles serving only the appliance may be used.
FIG. 6

AIR SUPPLY

INSTALLATION PIPES

BAKING OVEN BAFFLE PLATE

ELECTRICAL