AGA GC3 Installation Instructions Manual
AGA GC3 Installation Instructions Manual

AGA GC3 Installation Instructions Manual

Hide thumbs Also See for GC3:

Advertisement

GC3
(THREE OVEN)
nstallation
nstructions
PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
CUSTOMER: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
FOR USE IN AUSTRALIA
08/15 EINS 512472

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GC3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AGA GC3

  • Page 1 (THREE OVEN) nstallation nstructions PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE. CUSTOMER: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE FOR USE IN AUSTRALIA 08/15 EINS 512472...
  • Page 2: Table Of Contents

    CONTENTS SECTION PAGE HEALTH & SAFETY INSTALLATION LOCATION APPLIANCE DIMENSIONS TECHNICAL DATA FLUE SYSTEM INSTALLATION PIPES AIR SUPPLY BAKING OVEN BAFFLE PLATE COMMISSIONING 8 - 10 INSTRUCTIONS...
  • Page 3: Health & Safety

    IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING WARRANTY. Any alteration that is not approved by AGA could invalidate the approval of the appliance, operation of the warranty and could also affect your statutory rights.
  • Page 4: Installation

    The Building Regulations. In addition, Planning Permission may need to be obtained, which should be applied for separately. The complete range of AGA cookers are suitable for Natural or Propane gases only and cannot be used on any other gas.
  • Page 5: Appliance Dimensions

    APPLIANCE DIMENSIONS Fig. 1 DESN 512841 B 889 851 679 467 1035 41 1330 756 1125 73 698 116 1 /2 1 /2 3 /4 1 /2 1 /2 3 /4 PLEASE NOTE: SIDE CLEARANCE DIMENSION W IS ALSO REQUIRED ON THE LH SIDE FOR THE BAKING OVEN DOOR.
  • Page 6: Technical Data

    TECHNICAL DATA - GC3 NATURAL G20 MAXIMUM HEAT INPUT 18MJ/hr (5kW) Thermostat Bypass 100 (1.0 mm) Main Burner Injector Multihole Injector 7 x .72mm Pilot Injector 4212 Burner Pressure 1kPa (10mbar) (4” wg) PROPANE G31 MAXIMUM HEAT INPUT 18MJ/hr 5kW (357g/h) Thermostat Bypass 60 (0.6mm)
  • Page 7: Flue System

    BAKING OVEN BAFFLE PLATE A metal plate (with square holes), which is provided in the AGA pack, MUST be positioned on the top runners of the Baking Oven. Slide the plate in fully, until it makes contact with the back of the oven.
  • Page 8: Commissioning

    COMMISSIONING Service Gas Valve Control Knob Piezo Ignitor Inlet Pressure Point Burner Pressure Test Point Fig. 2 DESN 512431 FIG. A FIG. B FIG. C FIG. D Fig. 3 DESN 512342...
  • Page 9 COMMISSIONING (CONTINUED) LIGHTING THE BURNER - FIG. 16 CAUTION NO SMOKING OR NAKED LIGHTS. Open the outer burner door to expose the gas control combination valve. CAUTION: BEFORE LIGHTING: ENSURE THAT THE GAS VALVE CONTROL KNOB 2 IS SET IN THE OFF POSITION (SEE FIG. 2 and 3A). Turn off Service Gas Valve 1.
  • Page 10: Instructions

    Hand these and the Operating Instructions to the User for retention and instruct in the safe operation of the appliance. Finally advise the User that, for continued efficient and safe operation of the appliance it is important that adequate servicing is carried out at regular intervals recommended by the AGA Distributor or local Gas Region.
  • Page 12 For further advice or information contact your local AGA Specialist With AGA Rangemaster’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time. Manufactured By...

Table of Contents