Air Supply; Installation Pipes; Baking Oven Baffle Plate; Electrical - AGA GC3 (PF) Installation Instructions Manual

Gas fired power flue cooker with aims
Hide thumbs Also See for GC3 (PF):
Table of Contents

Advertisement

AIR SUPPLY

Kitchen or Internal Space Air Supply
The appliance can only be installed in a room which meets ventilation regulations in force but in
2
any event the room must have a permanent vent of minimum free air of 36cm
.

INSTALLATION PIPES

Installation pipes should be fitted in accordance with current Gas Regulations. Pipework from the
meter to the cooker must be of adequate size, cooker connection size of 15mm Dia. On
completion test the gas installation for tightness and purge in accordance with the regulations in
force.

BAKING OVEN BAFFLE PLATE

A metal plate (with square holes) which is provided in the AGA pack MUST be positioned on the
top runners of the Baking Oven. Slide in the plate fully, until it makes contact with the back of the
oven.
This baffle is a permanent part of the Baking Oven, to regulate oven temperature.

ELECTRICAL

See Wiring Diagram (Fig. 7)
A 3 Amp 230V-50Hz fused electrical supply is required adjacent to the appliance. External wiring
to the fan unit must be installed using a 3-core heat resistant silicone sheathed cable and in
accordance with the current Wiring Regulations and any local regulations which apply.
The wiring should be completed as indicated:
The method of connection to the mains electricity supply must facilitate complete electrical
isolation of the appliance, preferably by the use of an unswitched shuttered socket outlet in
conjunction with a fused three pin plug. Alternatively, a fused double pole switch, having a
contact separation of at least 3mm in both poles serving only the appliance may be used.
12

Hide quick links:

Advertisement

Table of Contents
loading