Chapter 7 Installing Cards

Figure 13 Slot Setup (Install)

7.2.3 Remove an Interface Module

Remove the interface module from the MS-7206 chassis.

7.3 Physically Installing Management and Interface Modules

Use the following procedure to install management and interface modules in the chassis.
1 Grasp the center of the front panel of the module with one hand and place the other hand
under the module to support it.
2 Insert the module halfway into the slot and spread the two ejector levers outward. Make
sure the ejector levers are perpendicular to the front panel.
3 Slide the module into the slot until it makes contact with the backplane. The ejector
levers should be at a small angle to the front panel now.
4 Push the two ejector levers firmly until they are flush with the front panel.
5 Tighten the two thumbscrews.