Troubleshooting Solid State Drives; Troubleshooting Usb Devices - Dell PowerEdge M630 Owner's Manual

For dell poweredge vrtx enclosure
Hide thumbs Also See for PowerEdge M630:
Table of Contents

Advertisement

Troubleshooting Solid State Drives

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: This troubleshooting procedure can destroy data stored on the SSD. Before you
proceed, back up all the files on the SSD, if possible.
Steps
1.
Run the appropriate tests in system diagnostics.
If the tests fail, go to step 3.
2.
Take the SSD offline and wait until the indicator codes on the SSD carrier signal that the SSD may be
removed safely, then remove and reseat the SSD carrier in the server module.
3.
Restart the server module, enter the System Setup and confirm that the drive controller is enabled.
4.
Ensure that any required device drivers are installed and are configured correctly.
NOTE: Installing a SSD into another bay may break the mirror if the mirror state is optimal.
5.
Remove the SSD and install it in the other SSD slot.
6.
If the problem is resolved, reinstall the SSD in the original slot.
If the SSD functions properly in the original slot, the SSD carrier could have intermittent problems.
Replace the SSD carrier.
7.
If the SSD is the boot drive, ensure that the SSD is configured and connected properly.
8.
Partition and logically format the SSD.
9.
If possible, restore the files to the SSD.
If the problem persists, see
Related Links
Hard-drive/SSD indicator patterns
Removing a hard drive/SSD
Installing a hard drive/SSD

Troubleshooting USB devices

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1.
Ensure that the server module is turned on.
2.
Check the USB device connection to the server module.
3.
Swap the USB device with a known-working USB device.
Getting
Help.
99