Vitocell 100-V, Type Cvw - Viessmann VITOSOL 100-F SV Technical Manual

Table of Contents

Advertisement

DHW cylinders
(cont.)

11.4 Vitocell 100-V, type CVW

For DHW heating in conjunction with heat pumps up to 16 kW and
solar collectors; also suitable for boilers and district heating systems.
Suitable for the following system characteristics:
■ DHW temperature up to 95 °C
■ Heating water flow temperature up to 110 °C
Cylinder capacity
DIN register no.
Continuous output
For DHW heating from 10 to 45 °C and a heating
water flow temperature of ... at the heating water
flow rate stated below
Continuous output
For DHW heating from 10 to 60 °C and a heating
water flow temperature of ... at the heating water
flow rate stated below
Heating water flow rate for the stated continuous outputs
Draw-off rate
Drawable water volume
Without reheating
– Cylinder content heated to 45 °C,
water at t = 45 °C (constant)
– Cylinder content heated to 55 °C,
water at t = 55 °C (constant)
Heat-up time
For connection of a heat pump with 16 kW rated heating output
and a heating water flow temperature of 55 or 65 °C
– For DHW heating from 10 to 45 °C
– For DHW heating from 10 to 55 °C
Max. connectable heat pump output
At 65 °C heating water flow and 55 °C DHW temperature and the specified heating water
flow rate
Max. aperture area that can be connected to the solar heat exchanger set (acces-
sories)
– Vitosol-F
– Vitosol-T
Performance factor N
in conjunction with a heat pump
L
Cylinder storage temperature
Standby heat loss q
BS
Dimensions
Length (7)
– Incl. thermal insulation
– Excl. thermal insulation
Total width
– Incl. thermal insulation
– Excl. thermal insulation
Height
– Incl. thermal insulation
– Excl. thermal insulation
Height when tilted
– Excl. thermal insulation
Weight incl. thermal insulation
Total weight in operation
incl. immersion heater
Heating water content
Heating surface
Connections
Heating water flow and return (male thread)
Cold water, DHW (male thread)
Solar heat exchanger set (male thread)
VITOSOL
■ Solar flow temperature up to 140 °C
■ Operating pressure on the heating water side up to 10 bar
(1.0 MPa)
■ Operating pressure on the solar side up to 10 bar (1.0 MPa)
■ Operating pressure on the DHW side up to 10 bar (1.0 MPa)
l
90 °C
kW
l/h
80 °C
kW
l/h
70 °C
kW
l/h
60 °C
kW
l/h
50 °C
kW
l/h
90 °C
kW
l/h
80 °C
kW
l/h
70 °C
kW
l/h
3
m
/h
l/min
l
l
min
min
kW
m
2
2
m
45 °C
50 °C
kWh/24 h
mm
mm
mm
mm
mm
mm
mm
kg
kg
l
2
m
R
R
R
390
9W173-13MC/E
109
2678
87
2138
77
1892
48
1179
26
639
98
1686
78
1342
54
929
3.0
11
15
280
280
60
77
16
11.5
6
2.4
3.0
2.5
859
650
923
881
1624
1522
1550
190
582
27
4.1
¾
VIESMANN
71