Viessmann VITOSOL 100-F SV Technical Manual page 101

Table of Contents

Advertisement

Installation accessories
Pump curves
600
60
500
50
400
40
300
30
200
20
100
10
0
0
0
0.5
Pump rate in m³/h
16.7
0
8.3
Pump rate in l/min
3-stage circulation pump, type PS10 and P10
A Pressure drop curve
B Head at output stage I
800
80
600
60
400
40
200
20
0
0
0
Pump rate in m³/h
0
Pump rate in l/min
High efficiency circulation pump, type PS10 and P10
A Pressure drop curve
B Max. head
VITOSOL
(cont.)
A
D
C
B
1
1.5
2
2.5
25
33.2
41.7
B
A
0.5
1.0
8.3
16.7
C Head at output stage II
D Head at output stage III
3
50
1.5
2.0
25
33.2
12
VIESMANN
101