P126730-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING AVERTISSEMENT AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Astria
TM
PFS
Models
®
C
US
Devonshire36TEN
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Une barrière conçue pour réduire le risque de brûlure
par le hublot chaude est fournie avec l'appareil et doit
être installé.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE
AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE
TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
Direct-Vent Gas Fireplace
Devonshire36TEP
Devonshire42TEN
Devonshire42TEP
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA TOCAR
EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 126730-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria 126730-01

  • Page 1 Installation and Operation Instructions Astria Direct-Vent Gas Fireplace P/N 126730-01 Rev. A 1/2014 Models ® Devonshire36TEN Devonshire36TEP Devonshire42TEN Devonshire42TEP P126730-01 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil. CONSUMER: Retain this manual for future reference.
  • Page 2 TABLE OF CONTENTS SAFETY IMPORTANT: Read this owner’s WARNING: Improper instal- manual carefully and completely lation, adjustment, alteration, before trying to assemble, op- service or maintenance can cause injury or property damage. Refer to this manual for correct can cause serious injury or installation and operational procedures.
  • Page 3 SAFETY Continued Get fresh air at once! Natural and Propane/LP Gas: Any parts removed for servicing must be replaced prior to operat- WARNING: This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for Due to high temperatures, the appliance should be located out of appliance.
  • Page 4 Carefully supervise young chil- dren when they are in the room Keep the area around your materials, gasoline and other are used or stored. See Cleaning and Maintenance National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. www.Astria.US.com 126730-01A...
  • Page 5: Local Codes

    LOCAL CODES National Fuel Gas Code ANSI Z223.1/NFPA 54* CSA- B149.1 Installation Code PRODUCT IDENTIFICATION Figure 1 - Direct Vent Fireplace PRODUCT FEATURES www.Astria.US.com 126730-01A...
  • Page 6: Pre-Installation

    RIGHT SIDE ELECTRICAL GAS LINE OUTLET KNOCK OUT 2.25" 6.75" (36" MODEL) 10.75" (42" MODEL) 11.50" NAILING FLANGE LEFT SIDE GAS LINE KNOCK 2.25" (36" MODEL) 10.75" (42" MODEL) 11.50" Figure 4 - Electrical Outlet and Gas Knockout Locations www.Astria.US.com 126730-01A...
  • Page 7: Framing And Finishing

    This will help circulate the heat Figure 6 - Framing Clearances for Corner throughout the house. Installation FRAMING AND FINISHING Wall Note: Noncombustible mantels may discolor! Mantel Mantel from Ref. Depth Ref. Top of Opening Figure 7 - Clearances for Combustible Mantels www.Astria.US.com 126730-01A...
  • Page 8: Location Of Termination Cap

    Noncombustible Combustible - 6" (15.2 cm) H = 24" (61 cm) G = 12" (30.5 cm) minimum clearance Noncombustible - 2" (5.1 cm) J = 20" (50.8 cm) Figure 8 - Minimum Clearances for Termination Cap www.Astria.US.com 126730-01A...
  • Page 9: Requirements For The Commonwealth Of Massachusetts

    REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS INSPECTION INSTALLATION OF CARBON MONOXIDE DETECTORS MANUFACTURER REQUIREMENTS Gas Equipment Venting System Provided Gas Equipment Venting System Not Provided SIGNAGE www.Astria.US.com 126730-01A...
  • Page 10: Venting Installation

    2" clearances Failure to do so could result in from the top of the pipe. Where serious injury, property damage the termination cap penetrates or loss of life. a combustible wall, 1" air space clearance is required. www.Astria.US.com 126730-01A...
  • Page 11: Installation Planning

    " Inside Framing " " Twist-Lock Procedure: (Framing Detail) Vent Opening Noncombustible Wall " Note: Horizontal runs of vent must be sup- ported every three feet. Use wall straps for this purpose. an 11 Figure 10 - Vent Opening Requirements www.Astria.US.com 126730-01A...
  • Page 12 (see Figure 11). IMPORTANT: Vent Connecting Vent Cap with Horizontal Vent Pipe: Figure 12 - Installing Siding Standoff (Combustible Exterior Wall) Figure 11 - Installing Horizontal Vent Cap (Noncombustible Exterior) Figure 13 - Connecting Vent Cap with Horizontal Vent Pipe www.Astria.US.com 126730-01A...
  • Page 13 WARNING: Never run vent downward as this may cause improperly installed and main- tained venting system could Figure 14 - Typical Horizontal result in serious injury, property Termination Cap Mounting with damage or loss of life. Additional Siding Standoff Installed www.Astria.US.com 126730-01A...
  • Page 14 GROUND FLOOR INSTALLATION (V) Vertical Required (H) Horizontal Minimum Vertical Pipe Figure 15 - Horizontal Termination Using One 90° Elbow Venting with Two 90° Elbows Horizontal (H Vertical (V) Horizontal (H Figure 16 - Horizontal Termination Using Two 90° Elbows www.Astria.US.com 126730-01A...
  • Page 15 Use wall straps for this purpose (see Figure 17). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers Vent Termination Chart Minimum Height Roof Pitch Feet Min. Figure 17 - Offset with Wall Strap and 45° Elbows www.Astria.US.com 126730-01A...
  • Page 16 Increasing vent height may solve this problem. PARTS LIST FOR VENTING KITS AND COMPONENTS INNOVATIVE HEARTH PRODUCTS (5/8") Pipe & Vent Kits Number Description Figure 18 - Installing Firestop HTS-58 www.Astria.US.com 126730-01A...
  • Page 17 VENTING INSTALLATION Continued Vertical Venting Note: Venting with Two 90° Elbows Vertical (V Horizontal (H) www.Astria.US.com 126730-01A...
  • Page 18: Check Gas Type

    If pipe is too small, undue loss of volume will occur. LP supply. WARNING: For natural IMPORTANT: private (non-utility) gas wells. This gas is commonly known as wellhead gas. Installation Items Needed Figure 21 - External Regulator with Vent Pointing Down (Propane/LP Only) www.Astria.US.com 126730-01A...
  • Page 19: Connecting Fireplace To Gas Supply

    (LP) gas. Natural Propane/LP Gas Line CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed Figure 22 - Gas Connection Checking Gas Connections, Gas Line Note: Gas Line Figure 23 - Connecting Incoming Gas Line to Flex Gas Line www.Astria.US.com 126730-01A...
  • Page 20: Checking Gas Connections

    (3.5 kPa) Figure 25 - Checking Gas Joints for Propane/LP Gas Fireplace Test Pressures Equal To or Less Than Figure 26 - Checking Gas Joints for 1/2 PSIG (3.5 kPa) Natural Gas Fireplace PRESSURE TESTING FIREPLACE GAS CONNECTIONS www.Astria.US.com 126730-01A...
  • Page 21 Replacement Parts, page 33. Replacing Glass Door CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass. Let cool before removing glass doors. www.Astria.US.com 126730-01A...
  • Page 22 AND SCRAP LOG INSTALLATION Removing/Re- placing Glass Door 2. For 36" models only: Figure 28b - Installing Loose Logs #2 and #3 Figure 28 - Installing Loose Logs Figure 29 - Installing Lava Rock Figure 28a - Installing Loose Log #1 www.Astria.US.com 126730-01A...
  • Page 23 5. For 36" models only: Figure 31 - Installing Scrap Log Pieces CONNECTING AND DISCONNECTING GAS LINE vice person must connect and supply. Follow all local codes. Figure 32 - Connecting/Disconnecting Gas Line to Millivolt Valve www.Astria.US.com 126730-01A...
  • Page 24: Operation

    LIGHTING INSTRUCTIONS Installing Batteries in Remote Control NOTICE: During initial operation Unit will give off a paper-burning be present. Open damper or window to vent smell. This will only last a few hours. www.Astria.US.com 126730-01A...
  • Page 25: To Turn Off Gas To Appliance

    OPERATION Continued Turn Off Gas To Appliance TO TURN OFF GAS TO APPLIANCE Gas Line Figure 34 - Turning Equipment Shutoff Valve to the OFF Position BLOWER CONNECTION AND OPERATION Note: Magnet Magnet Figure 35 - Blower Assembly www.Astria.US.com 126730-01A...
  • Page 26: Gas Control Module System

    Figure 36 - Blower Assembly, Speed Control and Wiring Diagram Location GAS CONTROL MODULE SYSTEM Continuous Pilot ADJ. Remote/Off Switch Off/On Switch CONTINUOUS PILOT FEATURE “S” Pilot Connection “I” Pilot Connection AF-4000 MOD Module Rt Side Figure 37 - Gas Module Right Side REMOTE CONTROL FEATURE www.Astria.US.com 126730-01A...
  • Page 27: Battery Backup

    Figure 38 - Gas Module Left Side AF-4000 MOD Module Lt Side BATTERY BACK-UP INSPECTING BURNERS BURNER FLAME PATTERN PILOT ASSEMBLY To Turn Off Gas to Appliance, Troubleshooting Troubleshooting Sensing Figure 40 - Typical Flame Pattern Figure 39 - Correct Pilot Flame Pattern www.Astria.US.com 126730-01A...
  • Page 28: Cleaning And Maintenance

    Glass Door damage glass. Use a nonabra- sive household glass cleaner to WARNING: Do not operate clean glass. Do not clean glass when hot. latched, removed, cracked or broken. PILOT AND BURNERS LOGS Removing/Replacing Glass Door See Replacement Parts www.Astria.US.com 126730-01A...
  • Page 29: Venting System

    VENTING SYSTEM TROUBLESHOOTING CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Replacement Parts, Wiring Diagram www.Astria.US.com 126730-01A...
  • Page 30 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY the CONTINUOUS PILOT www.Astria.US.com 126730-01A...
  • Page 31 OBSERVED PROBLEM POSSIBLE CAUSE REMEDY See Warning statement at top of page (see Checking Gas Con- nections See Warning statement at top of page (see Checking Gas Con- nections Venting Installation as needed www.Astria.US.com 126730-01A...
  • Page 32: Specifications

    HI/LO DC Pilot Motor Drive Control Valve Main Module Power Orange Module Black BATTERY PACK Brown Black SIZE SIZE SIZE SIZE "AA" "AA" "AA" "AA" Black To Ground Brown To Rocker Switch Brown Black Black To J-Box Power Adapter www.Astria.US.com 126730-01A...
  • Page 33: Replacement Parts

    This will protect your warranty coverage for parts replaced under warranty. TECHNICAL SERVICE SERVICE HINTS When Gas Pressure Is Too Low www.IHP.US.com ACCESSORIES Propane/Natural Gas Conversion Kit Remote Control Kit - WRC Series Brick Perimeter Trim Kit Ledgestone Refractory Liner Kit www.Astria.US.com 126730-01A...
  • Page 34 PARTS MODELS DEVONSHIRE36TEN, DEVONSHIRE36TEP, DEVONSHIRE42TEN AND DEVONSHIRE42TEP 33(36") 32(42") www.Astria.US.com 126730-01A...
  • Page 35 PART NO. DESCRIPTION 125105-01 125105-02 125103-01 125103-02 121301-01 121301-02 125107-01 125107-02 125108-01 125108-02 125108-03 125108-04 123210-01 123210-02 122652-01 121431-01 111913-02 122919-01 121295-01 121302-01 110037-01 117891-01 120520-01 20280 123182-01 123181-01 123211-01 125104-01 125104-02 109720-03 PARTS AVAILABLE NOT SHOWN 126469-01 www.Astria.US.com 126730-01A...
  • Page 36 PARTS MODELS DEVONSHIRE36TEN, DEVONSHIRE36TEP, DEVONSHIRE42TEN AND DEVONSHIRE42TEP www.Astria.US.com 126730-01A...
  • Page 37: Burner Assembly

    15 111817-09 17 125063-01 125063-02 18 111800-01 19 125064-01 20 125067-01 21 14396 22 116786-01 23 125061-01 25 125062-01 26 125068-01 27 125072-03 28 125072-03 29 125098-01 PARTS AVAILABLE NOT SHOWN 112799-01 26839 GA6060 VTA-LS5-2 125069-01 14253 125065-01 125066-01 www.Astria.US.com 126730-01A...
  • Page 38 PARTS REFRACTORY PARTS Herringbone Brick Shown Replacement Parts NO. PART NO. DESCRIPTION 125124-03 125088-03 125123-03 125087-03 125126-03 125090-03 125123-03 125089-03 125128-03 125092-03 125127-03 125091-03 125129-03 125093-03 125131-03 125095-03 125130-03 125094-03 www.Astria.US.com 126730-01A...
  • Page 39 NO. PART NO. DESCRIPTION 125124-02 125088-02 125123-02 125087-02 125126-02 125090-02 125123-02 125089-02 125128-02 125092-02 125127-02 125091-02 125129-02 125093-02 125131-02 125095-02 125130-02 125094-02 NO. PART NO. DESCRIPTION 125123-04 125087-04 125125-04 125089-04 125127-04 125091-04 125129-04 125093-04 125131-04 125095-04 125130-04 125094-04 www.Astria.US.com 126730-01A...
  • Page 40 THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 41 KEEP THIS WARRANTY _____________________________ __________________________ __________________________ www.Astria.US.com 126730-01A...
  • Page 42 NOTES...
  • Page 43 NOTES www.Astria.US.com 126730-01A...
  • Page 44 126730-01 1-800-655-2008 www.IHP.US.com P126730-01...