Astria Georgian 42 Installation And Operation Instructions Manual

Wood burning fireplace

Advertisement

P/N 126637-01 Rev. B 02/2014
P126637-01
This book is valuable. In addition to instructing you on how to install and manintain your appliance, it also contains
information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other
important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This fireplace is approved for use as a wood furning fireplace or for use with a vented gas log approved to
ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a
permit.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Astria
TM
PFS
Models
®
Georgian 36
C
US
SAVE THIS BOOK
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
POUR LE CANADA: L'autorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l'installation afin de déterminer la
nécessité d'obtenir un permis.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
Wood Burning Fireplace
Georgian 42
Georgian 50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Georgian 42 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Georgian 42

  • Page 1 Wood Burning Fireplace P/N 126637-01 Rev. B 02/2014 Models ® Georgian 36 Georgian 42 Georgian 50 P126637-01 SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and manintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualified installer or local distributor. TABLE OF CONTENTS Safety ..............2 Glass Door Installation ........
  • Page 3: Specifications

    SPECIFICATIONS 36" MODEL 29" " " " " 19" (Ref.) " " " " " 36" HEARTH 11" OUTSIDE AIR 67" ACCESS 61" 58" 49" GAS LINE 30" ACCESS " " 7" 1" " 36" " " 1" " 11" "...
  • Page 4 (Ref.) 29" " " " 42" HEARTH " 5/8" OUTSIDE 11" ACCESS 58" 67" 61" GAS LINE 49" ACCESS 30" " " 7" " " 42" " 1" 13" " 17" Figure 2 - 42" Model Georgian 42 www.Astria.US.com 126637-01B...
  • Page 5 " (Ref.) " " " " " 50" HEARTH OUTSIDE 11" ACCESS 67" GAS LINE 58" 49" ACCESS 61" 30" " " 7" " 1" " 50" " 59" 13" 17" Figure 3 - 50" Model Georgian 50 www.Astria.US.com 126637-01B...
  • Page 6: Fireplace Installation

    65" (42" Models) flue gas outlet (see Figure 15, page 11). Back of Fireplace 71" (50" Models) " Clearance Not Required at Nailing Flanges 86.5" (36" Models) 92" (42" Models) 100" (50" Models) Figure 5 - Corner Installation www.Astria.US.com 126637-01B...
  • Page 7: Hearth Extension

    Seal Gap Combustible Elevated Material Must Min. to Not Overlap Perpendicular Front Face Side Wall Ember Protector 12" - 36" Models Figure 6 - Hearth Extension 18" - 42/50" Models Figure 7 - Mantel Clearances to Combustible Material www.Astria.US.com 126637-01B...
  • Page 8: Venting Installation

    Press down on each pipe section until the Canada, use chimney parts designated "HT". lances securely engage the hem on the fireplace starter. The wire will assure the proper spacing between the inner and outer pipe sections. www.Astria.US.com 126637-01B...
  • Page 9 Figure 11 - Ceiling Support Pipe 12S-12DM Screws CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ ROOF MUST BE MAINTAINED. WARNING: DO NOT INSTALL IN SLEEPING ROOM OF MOBILE HOMES. Figure 10 - Elbow Offset www.Astria.US.com 126637-01B...
  • Page 10 3. Use roof opening chart (Figure 15, page Staples 11) to determine correct opening length (Min. of 8) and flashing required. Figure 13 - Firestop Spacer with Living 4. Remove shingles around opening mea- Space Above Ceiling sured. Cut out this section. www.Astria.US.com 126637-01B...
  • Page 11 Used Flashing Pipe Caulk "A" Max. Model No. Flat 0° 19.5" V6F-10DM Storm 0-6/12 26.6° V6F-10DM Flashing Collar 6/12-12/12 45.0° 27" V12F-10DM Roof Opening 42" and 50" Models Figure 15 - Roof Opening Measurements Figure 17 - Storm Collar www.Astria.US.com 126637-01B...
  • Page 12 Note: If a decorative shroud is to be installed, louvered slots or any other opening. When contact the manufacturer for specifications. overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive. www.Astria.US.com 126637-01B...
  • Page 13 INSTALL THIS KIT, CONTACT YOUR LOCAL DISTRIBUTOR OR BRACKET (2x) DEALER. WARNING RIGHT BRICK PANEL LIFTING HAZARD SINGLE -PERSON LIFT COULD CAUSE INJURY. USE ASSISTANCE WHEN MOVING BOTTOM BRICK PANEL OR LIFTING. ASH PANEL Figure 22 - Installing Refractory Panels www.Astria.US.com 126758-01A...
  • Page 14: Firebrick Wall Installation

    3. The overall length of piping bag should be about 16". If the bag is longer than 16", cut it down to size by removing end with larger opening. This will make the bag easier to handle. www.Astria.US.com 126637-01B...
  • Page 15 INNOVATIVE HEARTH PRODUCTS grate only Leading (see Parts, page 20). This grate Bricks has been designed to keep the operation of your fireplace safe and efficient. Figure 23 - Installing Fireplace Screen Figure 24 - Installing Grate Retainers www.Astria.US.com 126637-01B...
  • Page 16: Optional Gas Line Installation

    Standard for Decorative Gas Appliance for Installation in Solid Fuel FIED SERVICE PERSON. Burning Fireplaces, ANS Z21.60 or Z21.84 and shall also be installed in accordance with the National Fuel Gas Code, ANSI 7223NFPA 54 latest edition. www.Astria.US.com 126637-01B...
  • Page 17: Glass Door Installation

    Only doors certi- fied with the appliance shall be used. WARNING: Do not slam or strike doors. Damage can result Figure 27 - Installing Top Door Frame in a hazardous condition. www.Astria.US.com 126637-01B...
  • Page 18: Door Adjustment

    The following tips should Always keep the fire well back from the doors be followed to assure that both the fireplace and never allow flames to contact the glass. www.Astria.US.com 126637-01B...
  • Page 19 To Close and smoke. Damper Damper Weight Doors Fully Closed Fireplace Front To Open Damper Figure 32 - Operating Damper Handle Doors Fully Opened Fireplace Front Figure 31 - Bi-Fold Glass Doors www.Astria.US.com 126637-01B...
  • Page 20: Parts

    PARTS MODELS 36", 42", AND 50" 16/17 www.Astria.US.com 126637-01B...
  • Page 21 Grate 42" • 109496-01 Grate 50" • PARTS AVAILABLE NOT SHOWN 124174-01 Grate Retainer • • • 109714-02 Side Firebrick Wall Spacers • • • 114913-01 Rear Firebrick Wall Spacers • • • ** Not a field replaceable part. www.Astria.US.com 126637-01B...
  • Page 22 Mosaic50M4 Red Split Stacked F0351 Mosaic50M2 Ivory Stacked F0352 Mosaic50M4 Ivory Split Stacked F0353 Mosaic50M3 Red Herr Full Stack F0354 Mosaic50M5 Red Herr Split Stack F0355 Mosaic50M3 Ivory Herr Full Stack F0356 Mosaic50M5 Ivory Herr Split Stack F0357 www.Astria.US.com 126637-01B...
  • Page 23 Herringbone Creamer F0372 Estate42P3 Herringbone Gray F0373 Estate50P2 Stacked "Rust" F0374 Estate50P2 Stacked Cappuccino F0375 Estate50P2 Stacked "Creamer" F0376 Estate50P2 Stacked Gray F0377 Estate50P3 Herringbone "Rust" F0378 Estate50P3 Herringbone Cappuccino F0379 Estate50P3 Herringbone Creamer F0380 Estate50P3 Herringbone Gray F0381 www.Astria.US.com 126637-01B...
  • Page 24: Technical Service

    Model and serial number information are in the replace parts under warranty. fireplace's rating plate located on the fireplace Note: Use only original replacement parts. smoke shelf. This will protect your warranty coverage for parts replaced under warranty. www.Astria.US.com 126637-01B...
  • Page 25: Accessories

    BDMO50G - 50" Pewter BDMO50C - 50" Oiled Bronze OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION - AK4F DOUBLE WALL PIPE 12-12DM, 18-12DM, 24-12DM, 36-12DM, 30° OFFSET AND RETURN 48-12DM, 12-12HT, 18-12HT, 24-12HT, 36- 30E-12DM and 30E-12HT 12HT and 48-12HT www.Astria.US.com 126637-01B...
  • Page 26 SIDEWALL INSTALLATION - AK4 FIRESTOP SPACER - FS-10 AND 1100EFS-10DM ROOF FLASHING V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch ROUND TOP TERMINATIONS RLT-12D AND RLT-12HT SQUARE CHASE-TOP TERMINATION - STL-12D AND STL-12DMP BLACK www.Astria.US.com 126637-01B...
  • Page 27 48-12HT* 48" Section Double Wall Pipe 30E-12HT 30" Offset and Return 12S-12HT Chimney Support RLT-12HT* Round Top with Louvers AP-12HT Anchor Plate/ Collar Assembly (Masonry) CAK-12 Cold Air Collar Kit *When ordered alone, this part ships freight only. www.Astria.US.com 126637-01A...
  • Page 28: Year Limited Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Astria™ brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited War- ranty against thermal breakage only.
  • Page 29 KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.Astria.US.com 126637-01B...
  • Page 30 NOTES www.Astria.US.com 126637-01B...
  • Page 31 NOTES www.Astria.US.com 126637-01B...
  • Page 32 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126637-01A 1-800-655-2008 Rev. B www.IHP.US.com 02/14 P126637-01...

This manual is also suitable for:

Georgian 50Georgian 36

Table of Contents