INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property
damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
PFS
®
C
US
Report No. F11 -026
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pourrait
d'entraîner des blessures graves, la mort ou des dom-
mages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage de
cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
For more information, visit Astria.US.com
Installation and Operation Instructions
Venice Lights™ Direct-Vent Linear Gas Fireplace
Models
VeniceLights43TEN
AVERTISSEMENT
VeniceLights43TEP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VeniceLights 43TEN and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria VeniceLights 43TEN

  • Page 1 — L’installation et l’entretien doivent être assurés par un — Installation and service must be performed by installateur ou un service d’entretien qualifié ou par le a qualified installer, service agency or the gas fournisseur de gaz. supplier. For more information, visit Astria.US.com...
  • Page 2: Safety And Your Fireplace

    LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO. Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla (vidrio) caliente es proveida con este aparato y deberá instalarse para la protección de los niños y otros individuos en riesgo. Astria.US.com 126727-01_D...
  • Page 3 (Page 33). températures élevées (Page 33) . temperaturas (Página 33).  Lisez L’information de sûreté  Read Important Safety Information  Lea Información importante de importante (Page 4) . (Page 4). seguridad (página 4). [ENGLISH] [FRENCH] [SPANISH] 126727-01_D Astria.US.com...
  • Page 4: Important Safety Information

    35. appliance be kept clean. See mainte- conduits de circulation d’air de l’appareil nance instructions on Page 35. soient tenus propres. Voyez les instructions d’entretien à la Page 35. Astria.US.com 126727-01_D...
  • Page 5: Table Of Contents

    NOTICE: Decorative product not for use as a heating service this fireplace. Improper use of this fireplace appliance. can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning. 126727-01_D Astria.US.com...
  • Page 6 More frequent cleaning may be needed due servicing an appliance must be replaced prior to to excessive lint and dust from carpeting, bedding material, etc. operating the appliance. Turn off the gas valve and pilot light before cleaning fireplace. Astria.US.com 126727-01_D...
  • Page 7: Local Codes

    • Your direct-vent gas fireplace system (fireplace and venting) is a venting instructions very carefully for either vertical or horizontal balanced and sealed gas operating unit. It requires approximately applications. 10-20 minutes of operating time before the flame pattern stabilizes. 126727-01_D Astria.US.com...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    (8) feet above grade and be directly in line with the horizontal termination. The sign must read, in print size no less than one-half (1/2) inch in size, GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS. Astria.US.com 126727-01_D...
  • Page 9: Pre-Installation

    5, page 10 for proper installation height. You can install noncom- bustible mantels at any height above the fireplace. NOTE: To avoid heat-related finish damage, we recommend the use of high temperature paint (rated 175° F or higher) on the underside of the mantel. 126727-01_D Astria.US.com...
  • Page 10 4" to Face Opening ZONE 5" 33° *Please refer to overall fireplace width (Figure 6, page11) before rough framing construction. 8" Perpendicular Figure 3 - Framing Clearances for See-Thru Application Wall Figure 5 - Clearances for Combustible Mantels Astria.US.com 126727-01_D...
  • Page 11 (416 mm) " (181 mm) " (105 mm) " 1" " 1" (210 mm) (25 mm) (1121 mm) (25 mm) " 47" (48 mm) (1194 mm) 52" (1321 mm) " (1400 mm) Figure 6 - VeniceLights43 Fireplace Series Dimensions 126727-01_D Astria.US.com...
  • Page 12: Location Of Termination Cap

    Noncombustible Combustible - 6" (15.2 cm) H = 24" (61 cm) G = 12" (30.5 cm) minimum clearance Noncombustible - 2" (5.1 cm) J = 20" (50.8 cm) Figure 7 - Minimum Clearances for Termination Cap Astria.US.com 126727-01_D...
  • Page 13: Venting Installation

    • Installation of any damaged venting component • Unauthorized modification of the venting system (Do not cut or alter vent components) • Installation of any component part not manufactured or approved by IHP • Installation other than as instructed by these instructions 126727-01_D Astria.US.com...
  • Page 14 Rigid Pipe, use SV4.5VF firestop/spacer at ceiling joists. vent sections (Figure 13, page 17). If there is living space above the ceiling level, the firestop/ spacer must be installed on the bottom side of the ceiling. Astria.US.com 126727-01_D...
  • Page 15 NOT the Same as the Centerline of the Framed Opening. 53” (1346 mm) Min. Plus 1/4”(6 mm) 6 to 48” Vent Section, Rise per Foot Telescopic vent section, Elbow or Appliance Collar Base of Appliance Figure 9 - Installing the Horizontal Termination 126727-01_D Astria.US.com...
  • Page 16 11-3/4 to 20” (299–508 mm) Table 2: Effective Vent Length tion (SV4.5L12) Table 1: Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits NOTE: See table 1 for wall thickness ranges when using SV4.5HTKCT termination kit. Astria.US.com 126727-01_D...
  • Page 17 1. Rotate the elbow in a clockwise direction (to avoid the pos- sibility of unlocking any of the previously connected vent sections) for proper alignment (Figure 13). See Connecting the vent pipe for more information. Locking Incline Arrow Channel Figure 12 - Connected vent components 126727-01_D Astria.US.com...
  • Page 18 Wall firestop/ spacer SV4.5HF ** Wall firestop/spacer Venting with Three 90° Elbows SV4.5HF** Vertical (V) Horizontal (H + H feet (meters) feet (meters) 4' Min. (1.219) 20' Max (6.096) Figure 15a - Horizontal Termination Using Three 90° Elbows Astria.US.com 126727-01_D...
  • Page 19 Loop the tape around the vent, securing the ends of the tape to the framing. If desired, sheet metal screws #6 x 1/2” length may be used to secure the support straps to the vent pipe (Figure 18, page 20). 126727-01_D Astria.US.com...
  • Page 20 17 3/4” (451 mm) necessary. Additional screws may be used at section joints for added stability. Guide wires or roof support assemblies may be attached Figure 19 - Roof Framing Dimensions to the joint for additional support on multiple joint configurations. Astria.US.com 126727-01_D...
  • Page 21 (12.192 m) maximum Venting with Three 90° Elbows Vertical (V) Horizontal (H + H feet (meters) feet (meters) 4' Min. (1.219) 20' Max (6.096) Figure 24a - Vertical Venting Configuration Using Three 90° Elbows Figure 23 - Top Vent—Straight 126727-01_D Astria.US.com...
  • Page 22 Compact Termination for flex with 24” F1800 SFKIT24CT (610 mm) compressed flex H7748 H7748 36” of flex with two adaptors for mat- ing two rigid sections of vent together. *All compressed flex vents can be expanded up to two times. Astria.US.com 126727-01_D...
  • Page 23 3/4” 7. Install three (3) screws 120° apart through the flexible vent from the end of the flexible vent. and into the adaptor collar just below the gear clamp to provide additional security to the connection. 126727-01_D Astria.US.com...
  • Page 24: Fireplace Installation

    NPT tap must be upstream from fireplace (see Figure 28, page 25). IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance. Astria.US.com 126727-01_D...
  • Page 25 Gas Shutoff Kink Valve 1/2" NPT Incoming Gas Line Note: Outlet Pressure Tap 1) Wire connections not shown for Set Screw clarity 2) * 1/8" NPT Plugged Tapping Figure 29 - Connecting Incoming Gas Line to Flex Gas Line 126727-01_D Astria.US.com...
  • Page 26 (See Upgrading VeniceLights43 Series to Figure 30 - Equipment Shutoff Valve See-Thru Application page 28). 1. Using self-tapping screws provided and holes on rear panel as a guide, screw the rear panel to the fireplace as shown in Figure 33, page 27. Astria.US.com 126727-01_D...
  • Page 27 Figure 4. Tilt open glass door 45° from the top of firebox and lift up to release 36, page 28. door from retaining channel (see Figure 35). 126727-01_D Astria.US.com...
  • Page 28 The barrier is designed to reduce the risk of burns from hot glass. Do not operate the fireplace without the barrier installed. Upper Front Face Barrier Frame Channel Slot Bottom Front Face Figure 37 - Reinstalling barrier Astria.US.com 126727-01_D...
  • Page 29 Figure 42. Side Filler Access Rear Panel Door Bracket Retaining Bracket Flange on Face Side Panel Bottom Figure 40 - Removing Rear Interior Wall for See-Thru Figure 43 - Access Door for See-Thru Applications Applications 126727-01_D Astria.US.com...
  • Page 30 " " " (295 mm) (295 mm) (295 mm) (295 mm) (32 mm) " (89 mm) " (267 mm) " (267 mm) 3" (76 mm) " (41 mm) Figure 44 - Installing Exterior Door for See-Thru In/Out Application Astria.US.com 126727-01_D...
  • Page 31: Installer - Attaching Safety In Operation Warnings

    IHP étiquettes d’instructions de sécurité supplémentaires gratuitement. Juego de etiquetas de repuesto - Nº de cat. H8024 Astria.US.com Étiquettes de remplacement, n° cat. H8024 NOTE: English is red text on clear label. French Astria.US.com and Spanish are white text on black label.
  • Page 32: Operation

    3. Remove center brick/control cover. 4. Turn equipment shutoff valve clockwise to OFF. Do not force. 5. Replace center brick/control cover. Incoming Equipment Shutoff Gas Line Valve Figure 47 - Turning Equipment Shutoff Valve to the OFF Position Astria.US.com 126727-01_D...
  • Page 33: Homeowner - Attaching Safety In Operation Warnings

    Cat. No. H8024 Replacement Label Kit vous plaît contactez IHP ou votre revendeur le plus Juego de etiquetas de repuesto - Nº de cat. H8024 proche pour recevoir IHP étiquettes d’instructions Astria.US.com de sécurité supplémentaires gratuitement. Astria.US.com Étiquettes de remplacement, n° cat. H8024 NOTE: English is red text on clear label.
  • Page 34: Inspecting Burners

    If burner flame pattern differs from that described: • Turn fireplace off (see To Turn Off Gas to Appliance), page 32 • See Troubleshooting, page 40 Astria.US.com 126727-01_D...
  • Page 35: Cleaning And Maintenance

    Keep children and pets away from glass. To replace, follow steps in the reverse order. If glass has been broken, carefully remove glass door (see Remov- ing/Replacing Glass Door, page 27). Vacuum all glass pieces with a shop vacuum. 126727-01_D Astria.US.com...
  • Page 36: Gas Control Module System

    Once the module's internal receiver accepts the transmitter code, there will be a series of confirming beeps. • The remote system is ready for use. NOTE: Make sure the valve module and light module are plugged into the electric duct assembly. Astria.US.com 126727-01_D...
  • Page 37 LCD Display: When setting the Flame-A height, the Flame-A LIGHT Zone: Blank icon, and Flame-A setting number will flash in the FLAME Zone. FAN Zone: Blank TIME/PROG Zone: Day of Week, or Time of Day will Flash AUX Zone: Blank FLAME Zone: Blank 126727-01_D Astria.US.com...
  • Page 38: Specifications

    In manual ON and program modes of operation, the transmitter will send a communication safety transmission every 15 - min- utes. This signal is further processed by the ignition control module to verify the transmitter is communicating properly. Astria.US.com 126727-01_D...
  • Page 39: Wiring Diagram

    Black To Ground Brown To Rocker Switch Brown (+) Red Blk/White (+) Black (-) (-) Black 110V (J7860) MAX. 15 AMPS To Light Switch Power Light Black Adaptor Module 110V 3 Prong To J-Box MAX. 15 AMPS Plug 126727-01_D Astria.US.com...
  • Page 40: Troubleshooting

    Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of operation Astria.US.com 126727-01_D...
  • Page 41 1. Clean out air holes at burner inlets. Peri- odically repeat as needed 2. Burner flame holes blocked 2. Remove blockage 3. Improper venting or excessive blockage 3. Have vent system inspected, including termination cap. Remove any restrictions or obstruction 126727-01_D Astria.US.com...
  • Page 42: Parts

    PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 46 of this manual. Astria.US.com 126727-01_D...
  • Page 43 Remote Control • • J7867 30" Flex Line • • J7868 Wire Harness (See Wiring Diagram, Page 39) • • J7869 AC Adaptor (Power Cord) • • J6725 Clear Pebbles (6 lbs) • • J7871 Latch Opener • • 126727-01_D Astria.US.com...
  • Page 44 PARTS MODELS: VENICELIGHTS43TEN AND VENICELIGHTS43TEP Astria.US.com 126727-01_D...
  • Page 45 • J7888 Rear Wall • • J7889 Rail, Barrier Linear • • J7457 Barrier, 43" • • J7890 Retainer, safety Barrier • • J6434 Board,Concrete Top • • J6435 Board,Concrete Side • • **Not a field replaceable part 126727-01_D Astria.US.com...
  • Page 46: Replacement Parts

    When contacting your dealer please have your model CAT NO. MODEL DESCRIPTION and serial numbers of your fireplace ready. You can also visit our web site at Astria.US.com. LINEAR DECORATIVE FACE KITS REPLACEMENT PARTS Decorative Face Trim for 43" Linear F1036 DFT43B See Pages 42 to 45 for a complete replacement parts list.
  • Page 47: Warranty

    IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.
  • Page 48 Astria.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name P126727-01 Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.