Astria Altair40DMN Installation And Operation Instructions Manual

Direct vent gas fireplaces

Advertisement

P/N 900357-01 Rev. A 02/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900357-03.
P900357-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Installation and Operation Instructions
Astria
PFS
Models
Altair40DMN
®
C
US
Altair40DMP
Report No. F14-170
Altair40DEN
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec
la vitre chaude et doit être installé pour la protection
Des enfants et Des personnes à risques.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
• Si vous ne pouvez rejoindre le fournisseur de
— L'installation et l'entretien doivent être assurés par
Altair
Direct Vent Gas Fireplaces
TM
TM
AVERTISSEMENT:
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
gaz depuis un voisin. Suivez les instructions du
fournisseur.
gaz, appelez le service des incindies.
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Altair45DMN
Altair45DMP
Altair45DEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altair40DMN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Altair40DMN

  • Page 1 Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplaces P/N 900357-01 Rev. A 02/2015 Models Ce manuel est disponible en francais, simplement Altair40DMN Altair45DMN ® en faire la demande. Numéro de la pièce 900357-03. Altair40DMP Altair45DMP Report No. F14-170...
  • Page 2 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Astria™ Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la...
  • Page 4: Table Of Contents

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 TABLE OF CONTENTS PACKAGING GENERAL INFORMATION Packaging ..........Page The assembled vented gas fireplace heater is WARNING Introduction ..........Page packaged with: General Information ......... Page Commonwealth of Massachusetts 1 - logs in a carton located within the firebox.
  • Page 5 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 The appliance, when installed, must be electri- NOTE: Installation and repair should be done WARNING by a qualified service person. The appliance cally grounded and wired in accordance with...
  • Page 6: Commonwealth Of Massachusetts

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Gas Pressure - All Models Deration - At higher elevations, the amount of BTU fuel value delivered must be reduced Hi/Lo Flame Inlet (IN) Tables 2 and 3 show the appliances' inlet and...
  • Page 7: Cold Climate Insulation

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate...
  • Page 8: Vent Termination Clearances

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances Termination Heights For Vents These instructions should be used as a Above Flat Or Sloped Roofs TERMINATION HEIGHTS FOR VENTS ABOVE...
  • Page 9 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Inside Corner Outside Corner Recessed Location See Figure 5 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall...
  • Page 10: Appliance And Vent Clearances

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 MINIMUM CLEARANCES TO COMBUSTIBLES All Models Combustible Shelf Height - Inches (millimeters) Appliance And Vent Clearances Secure Vent Secure Flex (flex elbow) ® ® The appliance is approved with zero clearance to combustible materials on...
  • Page 11: Pre-Installation Steps

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 PRE-INSTALLATION STEPS Step 10. (Page 31) Install glass door front face IMPORTANT! assembly and hood.. The appliance is shipped with all gas controls Install top standoff Step 11.
  • Page 12 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 FIREPLACE AND FRAMING SPECIFICATIONS Framing should be constructed of 2x4 or larger lumber. Vent Framing - Top Vent Framing With One 90º Elbow 10-1/2 Models...
  • Page 13: Step 2. Routing Gas Line

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 FIREPLACE FRAMING SPECIFICATIONS Framing Model 40-1/8 67-3/4 47-7/8 25-11/16 33-7/8 5-3/4 7” (178mm) 40" 1019 1721 1216 45-1/8 72-3/4 51-7/16 25-1/16 36-3/8 7-1/2 45" 1146...
  • Page 14: Step 3. Appliance Vent Collar

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Step 3. VENT RESTRICTOR INSTALLATION Top Solid Cover Plate (shown U-SHAPED VENT RESTRICTOR INSTALLATION NOTE: Use these instructions only when installed over top vent hole)
  • Page 15: Vertical Termination Systems

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 VERTICAL TERMINATION SYSTEMS (ROOF) i t c i t c See Figure 23 on Page 16 and Figures 29 through i t c 33 on Pages 18 and 19 and their associated...
  • Page 16 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Vertical (Offset) Installation All of the appliances covered in this document D. Install firestop/spacer at ceiling - When using Secure Vent, use SV4.5VF firestop/spacer are fitted with collars having locking inclined Analyze the vent routing and determine the channels.
  • Page 17 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 F. Change vent direction to horizontal/inclined run - At transition from or to a horizontal/in- clined run, install the SV4.5E45 and SV4.5E90 Storm Collar elbows in the same manner as the straight vent sections.
  • Page 18 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 VERTICAL VENT FIGURES/TABLES TABLE A NOTE: Secure Vent (rigid vent pipe) is shown ® Ceiling H Maximum V Minimum in the figures; Secure Flex (flexible vent pipe) ®...
  • Page 19 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 VERTICAL VENT FIGURES/TABLES (continued) TABLE C Maximum H Maximum V Minimum (meters) (meters) (meters) feet feet feet (1.524) (0.610) (0.305) Ceiling Firestop/Spacer (3.048) (1.219) (0.610) SV4.5VF*...
  • Page 20: Horizontal Termination System

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 TYPICAL HORIZONTAL VENT INSTALLATION HORIZONTAL (OUTSIDE WALL) Support TERMINATION SYSTEM Horizontal / Inclined Run Building Brackets SV4.5HT-2 Support Figures 34, and Figures 38 to 43 on Pages...
  • Page 21 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 J. Assemble vent run to exterior wall - If not To help minimize water infil- previously measured, locate the center of the tration it is recommended that vent at the exterior wall.
  • Page 22 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 HORIZONTAL VENT FIGURES/TABLES TABLE F NOTE: Secure Vent components (rigid vent pipe and terminal) are ® H Maximum V Minimum shown in the figures; Secure Flex components (flexible vent pipe and ®...
  • Page 23 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 HORIZONTAL VENT FIGURES/TABLES (continued) TABLE H Maximum H Maximum V Minimum (meters) (meters) feet (meters) feet feet (1.524) (0.610) (0.305) (3.048) (1.219) (0.610) Ceiling (4.572) (1.829)
  • Page 24 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 HORIZONTAL VENT FIGURES/TABLES (continued) TABLE K Wall Firestop/Spacer Maximum H Maximum V Minimum SV4.5HF** feet (meters) feet (meters) feet (meters) (1.524) (0.610) (0.305) (3.048) (1.219) (0.610)
  • Page 25 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 VERTICAL OR HORIZONTAL VENTING USING SECURE FLEX ® KITS AND COMPONENTS FLEX VENT NOTE: OUTER PIPE IS PULLED AWAY TO Secure Flex venting kits and components may SHOW THE DETAIL OF THE INNER PIPE ®...
  • Page 26: Step 5. Field Wiring

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Step 5. FIELD WIRING B. Electronic Wiring Refer to Section A for millivolt appliances and (Figure 47) Section B for electronic appliances. The gas One of the following optional controls also may...
  • Page 27: Step 6. Optional Blower Kit Wiring

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 BLOWER CONTROL CIRCUIT WIRING Step 7. CONNECTING GAS LINE NOTE: Remote receiver should be located in the 120V, 60HZ, 1PH wall, or if installed in the control compartment, pulled all the way forward and completely to the Make gas line connections.
  • Page 28: Step 8. Verifying Appliance Operation

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Millivolt Appliance Checkout Optional Gas Flex Line Connector The pilot flame should be steady, not lifting 3/8" NPT x 3/8" 1/2" x 3/8" Flare Flare Fitting Shut-Off Valve or floating.
  • Page 29: Step 9. Installing Logs

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Step 9. INSTALL VOLCANIC STONE, Glowing Embers GLOWING EMBERS AND LOGS WARNING • DO NOT attempt to install the logs until the appliance instal- lation has been completed, the...
  • Page 30 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 40" AND 45" LOG PLACEMENT Number Description Log, Rear Log, Diagonal/Left Log, Diagonal/Right Log, Front/Left Log, Top/Right Log, Front/Center Catalog Number for the entire log set: 55M03...
  • Page 31 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Step 10. REMOVING AND INSTALLING Step 11. BURNER ADJUSTMENTS Locate the two (2) glass door spring latches at the top of the control compartment (see Figure...
  • Page 32: Step 10. Remove/Install Glass Door

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Burner Flame Adjustments 40" Model WARNING • Air shutter adjustment should only be performed by a quali- fied professional service tech- nician. • Ensure front glass panel are in place and sealed during adjustment.
  • Page 33: Step 13. Attaching Safety-In Operation Warnings

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 STEP 13. ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 34: Step 12. Hood Installation

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 INSTALLATION ACCESSORIES Step 12. HOOD INSTALLATION Listed Secure Vent Components ® Refer to Figures 63 and 64. All of these appliances must have hoods Cat. No.
  • Page 35 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 INSTALLATION ACCESSORIES CONTINUED Listed Secure Vent Components ® Listed Secure Flex Components ® Cat. # Model Description Cat. # Model Description These termination kits include firestop/spacer, gear clamps and flex adaptor.
  • Page 36: Gas Conversion Kits

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 GAS CONVERSION KITS Electronic SIT Systems Propane Gas To Natural Gas WARNING Conversion Kits Models Catalog No. This conversion kit shall be installed by a qualified service agency in accor- 40"...
  • Page 37 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Burner Orifice Sizes Burner Assembly Elevation 0-4500 feet ( 0-1372 meters) Model Nat.Gas Propane Pressure Series drill size (inches) drill size (inches) Regulator #40 (0.0980")* #53 (0.0595")*...
  • Page 38: Important Safety Information

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Important Safety Information L'information de sûreté importante 1. WARNING: Do not operate appliance with the glass front 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué...
  • Page 39 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES À COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD LA SÉCURITÉ...
  • Page 40: Installation, Service, And Maintenance Notices

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 APPLIANCE INSTALLATION, SERVICE, Turn off gas and electrical power to the WARRANTY INFORMATION fireplace and allow it to cool before AND MAINTENANCE NOTICES Your gas appliance is covered by a cleaning or servicing the appliance.
  • Page 41 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 These appliances comply with National Safety Deration - At higher elevations, the amount Inlet Gas Supply Pressure Standards and are tested and listed by PFS...
  • Page 42: Operation/Care Of Your Appliance

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Gas Controls/Control Compartment OPERATION AND CARE OF YOUR APPLIANCE Access WARNING The gas controls can be found behind the hinged drop-down panel. Young children should be carefully supervised when they are in the same room as the appliance.
  • Page 43: Variable Flame Adjustment

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Variable Flame Height Adjustment Variable Flame Height Adjustment Inlet Pressure Port All Electronic and Millivolt appliances are Manifold Pressure Port equipped with a variable gas control valve. Flame...
  • Page 44: Maintenance

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 MAINTENANCE WARNING: Do not use abrasive cleaners Replacing Logs on glass. Never clean the glass when it is hot. If the logs become damaged by accident or...
  • Page 45: Front Glass Enclosure Panel, Barrier, Removal And Installation

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Front Glass Enclosure Panel, Removal Only doors certified with the appliance Installing Glass Enclosure Panel (see Figure 70) and Installation shall be used. Retrieve the glass door. Visually inspect the Seules des portes certifiées pour cet...
  • Page 46: Install Volcanic Stone, Embers And Logs

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 INSTALL VOLCANIC STONE, GLOWING Glowing Embers EMBERS AND LOGS NOTE: Turn off all electricity to the appliance before you install volcanic stone, embers and logs.
  • Page 47 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 40" AND 45" LOG PLACEMENT Number Description Log, Rear Log, Diagonal/Left Log, Diagonal/Right Log, Front/Left Log, Top/Right Log, Front/Center Catalog Number for the entire log set: 55M03...
  • Page 48 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame.
  • Page 49: Adjustments

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Burner Flame Adjustments MILLIVOLT Hood Igniter Rod Burner Venturi WARNING Tube Thermocouple • Air shutter adjustment should Air Shutter only be performed by a quali-...
  • Page 50: Wiring Diagrams

    1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 A complete parts list is found at the end of When ordering repair parts, always give the visit us at www.Astria.us.com this manual. Use only parts supplied from the following information: manufacturer.
  • Page 51: Accessory Components

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 ACCESSORY COMPONENTS Cost Effective Solution State-of-the-art control with touch screen • Simple On/Off operation operation • Works with millivolt and low voltage electronic • Backlit LCD display ignition controls •...
  • Page 52 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 ACCESSORY COMPONENTS CONTINUED Termination Shroud (Fits H1968) Touch-Up Paint Kit Repair of minor scratches and discoloration of the appliance painted surfaces may be ac- complished with the touch-up paint kit.
  • Page 53 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Bag of Glowing Embers If the barrier that comes standard with this unit Bag of Decorative Volcanic Stone is damaged, discontinue ues of the fireplace Replacement ember material and volcanic stone until it is replaced.
  • Page 54: Maintenance Schedule

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 MAINTENANCE SCHEDULE Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance. Annually (Before the onset of the Burning Season)
  • Page 55: Lighting Instructions

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 LIGHTING INSTRUCTIONS - MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 56 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 INSTRUCTIONS D’ALLUMAGE - VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 57 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 LIGHTING INSTRUCTIONS - ELECTRONIC POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 58 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 INSTRUCTIONS D’ALLUMAGE - ELECTRONIC FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 59 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 TROUBLESHOOTING - MILLIVOLT GAS CONTROL SYSTEM NOTE: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, if applicable), is in the “ON”...
  • Page 60: Troubleshooting Guide

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 TROUBLESHOOTING GUIDE - ELECTRONIC GAS CONTROL SYSTEM NOTE: Before troubleshooting the gas control system, make sure the external gas shut off valve (located at gas supply inlet) is in the “ON”...
  • Page 61: Replacement Parts List

    Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 REPLACEMENT PARTS LIST Item No. Description 40" MODELS 45" MODELS Part No. Qty. Part No. Qty. Hood 97K52 97K53 Enclosure, Glass Front (Complete) H8122 H6225...
  • Page 62 Innovative Hearth Products Installation and Operation Instructions Astria Altair Direct Vent Gas Fireplace 900357-01, 02/2015 REPLACEMENT PARTS 40” AND 45” NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 63: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 64 Innovative Hearth Products Installation and Operation Instructions Astria™ Altair Direct Vent Gas Fireplace 900357-01, 02/2015 Astria.US.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name...

Table of Contents