Astria Vega36ZP2 Installation And Operation Instruction Manual

Unvented (vent-free) universal firebox

Advertisement

Quick Links

P/N 126694-01 Rev.B 03/2014
P126694-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for
the minimum fireplace size requirement.
Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for
the installation.
WARNING: For use only with a listed, gas-fired unvented decorative room heater not to exceed 40,000
Btu/H.
Do not build a wood fire.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Astria
TM
PFS
Models
®
US
Vega32ZP2
Unvented (Vent-Free) Universal Firebox
Vega36ZP2
Vega36ZP3
Vega42ZP2
Vega42ZP3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vega36ZP2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Vega36ZP2

  • Page 1 Installation and Operation Instructions Astria Unvented (Vent-Free) Universal Firebox P/N 126694-01 Rev.B 03/2014 Models ® Vega36ZP2 Vega42ZP2 Vega32ZP2 Vega42ZP3 Vega36ZP3 P126694-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ..............2 Installation ............10 Local Codes............3 Replacement Parts ..........21 Product Features ..........4 Technical Service..........21 Locating Firebox ..........4 Accessories ............22 Product Specifications ......... 5 Parts ..............24 Air For Combustion and Ventilation ..... 8 Warranty ............
  • Page 3: Local Codes

    SAFETY Continued as pine cones, vermiculite or rock wool. Firebox front and screen become Using these added items can cause very hot when running heater. sooting. Keep children and adults away 3. Use only the provided hood or appropri- from hot surface to avoid burns ate hood accessory.
  • Page 4: Product Features

    Before installation, consider the 4. Proper air for combustion and ventilation following: (page 8). 1. Where the firebox will be located. Allow for wall and ceiling clearances (see Installa- tion Clearances, page 11). 2. Everything needed to complete installation. www.Astria.US.com 126694-01B...
  • Page 5: Product Specifications

    PRODUCT SPECIFICATIONS 32" MODELS Figure 1 - Product Specifications 32'' Models www.Astria.US.com 126694-01B...
  • Page 6 PRODUCT SPECIFICATIONS Continued 36" MODELS Figure 2 - Product Specifications 36'' Models www.Astria.US.com 126694-01B...
  • Page 7 PRODUCT SPECIFICATIONS Continued 42" MODELS Figure 3 - Product Specifications 42'' Models www.Astria.US.com 126694-01B...
  • Page 8: Air For Combustion And Ventilation

    3. Confined Space * Adjoining rooms are communicating only if The information on page 8 through 10 will help there are doorless passageways or ventilation you classify your space and provide adequate grills between them. ventilation. www.Astria.US.com 126694-01B...
  • Page 9 54, the International Fuel Gas ances. Direct-vent draws combustion Code, or applicable local codes. air from the outdoors and vents to the outdoors. Example: 40,000 Gas water heater _________ Btu/Hr 39,000 Vent-free heater + ________ Btu/Hr 79,000 Total = ________ Btu/Hr www.Astria.US.com 126694-01B...
  • Page 10: Installation

    • in high traffic areas • in windy or drafty areas * Unless the installed log set is rated at 10,000 Btu/Hr or less in a bedroom or 6,000 Btu/Hr or less in a bathroom. www.Astria.US.com 126694-01B...
  • Page 11 D. Clearances from bottom of firebox to the this manual. floor is 0". These fireboxes can be installed as freestand- ing units against a wall with the approved, www.Astria.US.com 126694-01B...
  • Page 12 Of 16" to a perpen- approved gas logs. dicular wall as shown in figure 6, on page 11. Figure 7 - Minimum Mantel Clearances Figure 8 - Rough Opening Dimensions for Built-In Installation www.Astria.US.com 126694-01B...
  • Page 13 The firebox and cabinet mantel can be installed directly on the floor. A trim kit is Figure 9 - Attaching Firebox to Wall Studs included with the mantel accessories. Follow (Model May Vary From Illustration) instructions with mantel for installation. www.Astria.US.com 126694-01B...
  • Page 14 BK available on all units and BK3 avail- 13 and Figure 11). Firmly tap the center of able for Vega36ZP2 and Vega42ZP2 series. the knockout with a chisel until it is released. Model BK is a rotary squirrel cage type blower...
  • Page 15 Accessibility to the bottom on Figure 14 - Accessing Duplex Electrical 36" and 42" models only, can also be gained Outlet Installed in Bottom Right Side of through the access panel underneath the bot- Firebox www.Astria.US.com 126694-01B...
  • Page 16 Figure 15 - Blower Model BK Access Side View Blower Firebox Bottom Installed After Control Lower Knob Panel Blower Location Magnets Removed Control Shaft Figure 16 - Blower Model BK (Side View) Figure 17 -Attaching Speed Control (Model May Vary From Illustration) www.Astria.US.com 126694-01B...
  • Page 17 12" in front of blower (see Figure 18). 10. Replace all panels and/or brick bottom panel if previously removed. Wiring Diagram Decal 12" in Front of Blower Figure 18 - Location of Wiring Diagram Decal (Model May Vary From Illustration) www.Astria.US.com 126694-01B...
  • Page 18 ON/OFF 110/115 Panel Switch V.A.C. Black Blower Blower Blower BK3 Blower Motor Motor Motor Nuetral No. 1 No. 2 No. 3 Black Screws at Upper Flange Figure 20 - BK3 Wiring Diagram Figure 19 - Mounting BK3 Blower www.Astria.US.com 126694-01B...
  • Page 19 CAUTION: Combustion air inlet ducts shall not terminate in attic space. Air Inlet Eyebrow Vented Crawl Space Vent Hood (Check Local Codes Required for Before Installing in a Wall Installation Vented Crawl Space) Figure 21 - Outside Air Kit www.Astria.US.com 126694-01B...
  • Page 20 (Model May Vary From Illustration) fireplace (See Figure 25). Screen Pocket Hood Screws Figure 24 - Screen Pocket Location Figure 22 - Screw and Hood Placement (Model May Vary From Illustration) Access Panel Figure 25 - Locating Access Cover Plate www.Astria.US.com 126694-01B...
  • Page 21: Replacement Parts

    You may have further questions about instal- You can also visit our web site at lation, operation, or troubleshooting. If so, www.IHP.US.com. contact INNOVATIVE HEARTH PRODUCTS at 1-800-655-2008. When calling please have your model and serial numbers of your heater ready. www.Astria.US.com 126694-01B...
  • Page 22: Accessories

    H42B - 42" Brushed Brass today's tightly constructed homes. H42P - 42" Platinum AK4F - Outside Air Kit for Floor Installation AK4X - Collar and Hood (accepts any length of 4" flex tube) AK4B - 50 pc. Bulk Collar Only Kits www.Astria.US.com 126694-01B...
  • Page 23 36" CORNER MANTELS C36TU - 36" Unfinished, Traditional C36TO - 36" Oak Stain, Traditional UNIVERSAL CABINET MANTEL (Fits 36" Models) LACMO - Large, Dark Oak Stain LACMW - Large, Dark Walnut Stain Note: No 42" mantels offered at this time. www.Astria.US.com 126694-01B...
  • Page 24: Parts

    PARTS MODELS 32" 36", AND 42" www.Astria.US.com 126694-01B...
  • Page 25 F0395 VEGA32ZP2 Flush Face 32" VF Firebox, White Stacked Brick F0396 VEGA32ZP2 Louver Face 32" VF Firebox, White Stacked Brick VEGA36ZP2 F0397 Flush Face 36" VF Firebox, White Stacked Brick VEGA36ZP2 F0398 Louver Face 36" VF Firebox, White Stacked Brick...
  • Page 26 PARTS MODELS Vega32ZP2, Vega36ZP2, Vega36ZP3, Vega42ZP2 and Vega42ZP3 www.Astria.US.com 126694-01B...
  • Page 27 125284-02 Bottom Front Refractory Red Stack • 125294-02 Bottom Front Refractory Red Stack • 125289-02 Bottom Front Refractory Red Herringbone • 125299-02 Bottom Front Refractory Red Herringbone • 116531-01 Retainer, Refractory • • • • • • • www.Astria.US.com 126694-01B...
  • Page 28 KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification.
  • Page 29: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 30 NOTES...
  • Page 31 NOTES...
  • Page 32 Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. 1508 Elm Hill Pike, Suite 108 P126694-01 Nashville, TN 37210 1-800-655-2008...

This manual is also suitable for:

Vega42zp2Vega32zp2Vega42zp3Vega36zp3

Table of Contents