Astria TaurusSTZ2 F0382 Installation And Operation Instructions Manual

Astria TaurusSTZ2 F0382 Installation And Operation Instructions Manual

Unvented (vent-free) universal firebox

Advertisement

Quick Links

P/N 126685-01 Rev.A 02/2014
P126685-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for
the minimum fireplace size requirement.
Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for
the installation.
WARNING: For use only with a listed, gas-fired unvented decorative room heater not to exceed 40,000
Btu/H.
Do not build a wood fire.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Astria
TM
PFS
Models
®
US
TaurusSTZ2 (Flush Faced - F0382)
Unvented (Vent-Free) Universal Firebox
TaurusSTZ2 (Louvered - F0383)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TaurusSTZ2 F0382 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria TaurusSTZ2 F0382

  • Page 1 Installation and Operation Instructions Astria Unvented (Vent-Free) Universal Firebox P/N 126685-01 Rev.A 02/2014 Models ® TaurusSTZ2 (Flush Faced - F0382) TaurusSTZ2 (Louvered - F0383) P126685-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement.
  • Page 2: Table Of Contents

    Ceiling fans can create drafts that alter burner WARNING: Do not use a flame patterns. Altered burner blower insert, heat exchanger patterns can cause sooting. insert or other accessory not ap- proved for use with this firebox. www.Astria.US.com 126685-01A...
  • Page 3 The firebox canopy (hood) must and efficient. not be modified or replaced with a canopy (hood) that may be provided with the unvented decorative room heater. www.Astria.US.com 126685-01A...
  • Page 4: Local Codes

    These cracks will not affect the performance of the firebox or vent-free gas logs. HEAT DEFLECTIVE HOOD Two (2) black painted steel hoods come standard with the unit, which must be installed for a safe operation. www.Astria.US.com 126685-01A...
  • Page 5: Product Specifications

    Projected installations can extend any Figure 2 - Projected Installation distance into the room. A projection may be ideal as a partition between two oth- erwise common areas when added to an existing, finished wall (see Figure 2). www.Astria.US.com 126685-01A...
  • Page 6: Air For Combustion And Ventilation

    * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them. www.Astria.US.com 126685-01A...
  • Page 7 National Fuel Gas Code, ANSI outdoors and vents to the outdoors. Z223.1/NFPA 54, the Internation- Example: al Fuel Gas Code, or applicable 40,000 Gas water appliance __________ Btu/Hr local codes. 39,000 Gas firebox logs + _________ Btu/Hr 79,000 Total = _________ Btu/Hr www.Astria.US.com 126685-01A...
  • Page 8: Installation

    In the the front, top or sides of the event of a power outage, you firebox can use unvented logs as your • in high traffic areas primary heat source. • in windy or drafty areas www.Astria.US.com 126685-01A...
  • Page 9 4" Min. from the Perpendicular than 8". Side Wall to the Edge of Facial B. Clearances from top of firebox opening to the ceiling should not be less than 42". Figure 6 - Minimum Clearance - Top View www.Astria.US.com 126685-01A...
  • Page 10 17). The brass trim will extend past sides of Facing Wall firebox approximately 1/2". This will cover the rough edges of the wall opening. If installing Figure 8 - Framing for Built-In Firebox a mantel above the firebox, you must follow Installation www.Astria.US.com 126685-01A...
  • Page 11 Carefully chisel the rough wall to fireplace opening edges of the hole you have made to smooth Figure 9 - Framing for Built-In Firebox edges. This hole will line up with the hole in Installation, Top View the metal floor. www.Astria.US.com 126685-01A...
  • Page 12 Permitted by Local Codes Manual Shutoff Valve is Located Under Firebox Floor on Either Side Alternative Gas Sediment Trap Line Location (Not Supplied) Figure 11 - Installing Gas Line and Figure 14 - Sediment Trap Installation Manual Shutoff Valve www.Astria.US.com 126685-01A...
  • Page 13 Plates Access Hole supply piping system at test pressures equal Figure 15 - Locating Electrical to or less than 1/2 psig (3.5 kPa). Connection and Gas Connection on Either Side of Fireplace www.Astria.US.com 126685-01A...
  • Page 14 The blower outlets must be installed flush to the outer cabinet for air to flow properly. Locating Holes Spring Latch Bottom Louver Figure 16 - Removing Bottom Louver www.Astria.US.com 126685-01A...
  • Page 15 4. Repeat steps 2 and 3 to install hood on End of Hood the opposite side of the firebox. Figure 18 - Typical Hood Installation CAUTION: Do not clean hood (Both Sides) with abrasive cleanser. Use only regular household cleaners and a smooth cloth. www.Astria.US.com 126685-01A...
  • Page 16: Operating Guidelines And Maintenance Instructions

    If they can’t supply original replace- ment part(s), call INNOVATIVE HEARTH Brick Liner PRODUCTS at 1-800-655-2008 for referral Figure 19 - Location of Firebox information. A list of authorized dealers can Identification Label be found by visiting www.IHP.US.com. www.Astria.US.com 126685-01A...
  • Page 17: Technical Service

    Purchase these accessories from your local dealer. If they can not supply these accessories call INNOVATIVE HEARTH PRODUCTS at 1-800-655-2008 for information. You can also write to the address listed on the back page of this manual. GA3750A An optional blower is available for use with this firebox. www.Astria.US.com 126685-01A...
  • Page 18: Parts

    PARTS MODELS TAURUSSTZ2 17** 10** 16** 16** 16** 11** 16** 16** 16** 16** 16** **These items are used on both sides of fireplace. www.Astria.US.com 126685-01A...
  • Page 19 Screw, #10 x 1/2, zinc PH • • 11165 Screw, #10 x 5/8, zinc PH • • 23469SA Spacer Front/Back Drywall • • 14123 Strain Relief • PARTS AVAILABLE - NOT SHOWN *** Not a field replaceable part. www.Astria.US.com 126685-01A...
  • Page 20: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 21 WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.Astria.US.com 126685-01A...
  • Page 22 NOTES www.Astria.US.com 126685-01A...
  • Page 23 NOTES www.Astria.US.com 126685-01A...
  • Page 24 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126685-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P126685-01...

This manual is also suitable for:

Taurusstz2 f0383

Table of Contents