Astria Craftsman 42P2 Installation And Operation Instructions Manual

Astria Craftsman 42P2 Installation And Operation Instructions Manual

Wood burning fireplaces

Advertisement

P/N 126662-01 Rev. D 10/2014
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain
replacement parts or accessory items when needed.
Keep it with your other important papers.
This fireplace is approved for use as a wood burning
fireplace or for use with a vented gas log approved
to ANS Z21.60, Z21.84 standards or for use with a
vent-free gas log heater approved to ANS Z21.11.2
standard. An INNOVATIVE HEARTH PRODUCTS, LLC
hood must be installed when using a vent-free log
heater (see Accessories, page 18).
PFS
®
C
US
REPORT NO. 10-078
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
For more information, visit Astria.US.com
INSTALLATION AND OPERATION
INSTRUCTIONS
Craftsman
Wood burning Fireplaces
MODELS
Craftsman 42P2
Craftsman 42P3
P126662 01
This wood burning fireplace complies with UL127-
CAN/ULC-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before instal-
lation to determine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Craftsman 42P2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Craftsman 42P2

  • Page 1 ANS Z21.11.2 INSTALLER: Leave this manual with the appliance. standard. An INNOVATIVE HEARTH PRODUCTS, LLC CONSUMER: Retain this manual for future reference. hood must be installed when using a vent-free log heater (see Accessories, page 18). For more information, visit Astria.US.com...
  • Page 2: Table Of Contents

    To help us keep you up-to-date on product information and of- Technical Service .................15 fers, please take a few moments to register your product online Parts ....................16 at Astria.US.com (Owner Resources/Product Registration). Accessories ..................18 Please read and understand these instructions before installing or operating.
  • Page 3 These woods burn excessively hot and may contain accumulated (1/8" [3 mm] or more) it shall be removed chemicals used to treat insects and fungus. When to reduce the risk of a chimney fire." burned, these chemicals can pose a significant hazard. 126662-01D Astria.US.com...
  • Page 4: Specifications

    HEARTH EXTENSION 66" X 20" MINIMUM 0" TO BOTTOM 12" EACH SIDE " 36" INNER DIA. " " " OUTER " DIA. 15" 39" 48" " ROUND TOP TERMINATION " 24" SQUARE CHASE-TOP 41" TERMINATION 8" 42" 48" " Astria.US.com 126662-01D...
  • Page 5: Fireplace Installation

    (28 gauge minimum) as sand-cement grout (see Figure 3, page 6). to prevent corrosion. 6. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace. 126662-01D Astria.US.com...
  • Page 6 Mantels or any other combustible material may come up to side edge Min. 12" from of black metal face of fireplace if projection from front face falls within Perpendicular Side Wall limits shown in Figure 6. Figure 6 - Side Mantel Clearance Astria.US.com 126662-01D...
  • Page 7: Venting Installation

    (see Figure 9, page 8). 4. Secure electrical cover plate with screws previously removed. Lineal gain is actual measurable length of a part after two or more Note: Electrical housing and cover plate have sharp edges. Wear parts are connected. protective gloves. 126662-01D Astria.US.com...
  • Page 8 (see Figure 12, page 10). Do Square Chase-Top 12" to not penetrate inner stainless. ETLO-8DM with Mesh & Slip "* Section * The lineal gain for the terminations is measured to the flue gas outlet height. Figure 9 - Lineal Gain Astria.US.com 126662-01D...
  • Page 9 Offset Elbow Figure 10 - Typical Offset Installation See Detail A Ceiling Support Pipe 12S-8DM 2" Min. See Detail B Straps Straps Straps Straps Detail B Detail A Angle Return Elbow Firestop Figure 11 - Ceiling Support Pipe 12S-8DM 126662-01D Astria.US.com...
  • Page 10 When double wall pipe passes through a framed opening into an attic space, firestop must be placed into an attic floor as shown in Figure 14, page 12. Figure 13 - Firestop Spacer with Living Space Above Ceiling Astria.US.com 126662-01D...
  • Page 11 30" above Underlap Shingles highest point of roof cutout. Termination and chimney must extend at Bottom a minimum of 36" above highest point where it passes through roof. Figure 16 - Flashing Installation 126662-01D Astria.US.com...
  • Page 12 Underlap Shingles Bottom Only sential openings such as louvered slots. When overlapping with a noncombustible facing material, use only noncombustible mortar Figure 18 - Termination or adhesive. Astria.US.com 126662-01D...
  • Page 13: Optional Gas Line Installation

    3. Run a 1/2" black iron gas line into fireplace through rear at set in this fireplace with chimney removed. gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting 126662-01D Astria.US.com...
  • Page 14: Operation And Maintenance

    WARNING: When using a decorative vented gas log, damper must be removed or permanently locked in fully open position and glass doors must be in fully open position. Doors Fully Opened Fireplace Front Figure 24 - Glass Doors Astria.US.com 126662-01D...
  • Page 15: Replacement Parts

    When calling your dealer please have your model and serial numbers of your fireplace ready. You can also visit our web Damper site at Astria.US.com. Handle Keyway Slot...
  • Page 16: Parts

    PARTS WOOD BURNING FIREPLACE MODELS: Craftsman 42P2 Craftsman 42P3 Astria.US.com 126662-01D...
  • Page 17 This list contains replaceable parts used in your fireplace. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. Craftsman 42P2 Craftsman 42P2 (F0711, F0712)
  • Page 18: Accessories

    Bottom Front - 107820-01 HERRINGBONE BRICK LINER RED STANDARD BRICK LINER RED Craftsman 42P3 (F0713, F0716) Left - 108169-02 Craftsman 42P2 (F0711, F0712, f0714, f0715) Right - 108170-02 Left - 107812-02 Rear - 108171-02 Right - 107814-02 Bottom Rear - 108172-02...
  • Page 19 SQUARE TOP TERMINATION WITH LOUVERS AND SLIP OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION - AK4 SECTION ETL-8DM, ETL-8HT MESH SQUARE TOP TERMINATION ETO-8DM MESH SQUARE TOP TERMINATION WITH SLIP SECTION ETLO-8DM OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F 126662-01D Astria.US.com...
  • Page 20 Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. P126662 01 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 1-800-655-2008 Printed in U.S.A.

This manual is also suitable for:

Craftsman 42p3

Table of Contents