Astria Aries 33 Installation And Operation Instructions Manual

Direct-vent gas fireplace

Advertisement

P/N 900004-01 Rev. G 03/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-03.
P900004-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Installation and Operation Instructions
Astria™ Aries Direct-Vent Gas Fireplaces
PFS
Models
Aries 33xxx *
®
C
US
Report No. F13-094
* "xxx" indicates unique model identifiers.
This manual covers all Astria™ Aries models.
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
— L'installation et l'entretien doivent être assurés par
Aries 35xxx *
Aries 40xxx *
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Aries 45xxx *

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aries 33 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Aries 33

  • Page 1 Numéro de la pièce 900004-03. Report No. F13-094 * “xxx” indicates unique model identifiers. This manual covers all Astria™ Aries models. P900004-01 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil.
  • Page 2 Innovative Hearth Products General Information Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la IHP fireplace get...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Traditional Fireplace Contemporary Fireplace THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: General Information

    Innovative Hearth Products General Information Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 GENERAL INFORMATION IMPORTANT SAFETY INFORMATION L’information de sûreté importante Información importante de seguridad WARNING AVERTISSEMENT ADVERTENCIA Do not operate appliance with the Ne pas utiliser l’appareil si le...
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 FIREPLACE INSTALLATION, OPERATION, AND MAINTENANCE NOTICES DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION, AND LISTINGS OF THIS UNIT.
  • Page 7 Innovative Hearth Products General Information Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 WARNING Clothing or other flammable material should not be placed on or near the appliance. AVERTISSEMENT On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
  • Page 8: Packaging

    Innovative Hearth Products General Information Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    900004-01, 04/2015 BTU Input Table 1: Input Rate, Gas Valves Input Rate (BTU/HR) Models Natural Gas Propane Gas Aries 33 / Aries CD 33 12,000 10,000 Aries 35 / Aries CD 35 14,000 12,000 Aries 40 / Aries CD 40...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Table 5: Burner Orifice Sizes, Elevation 0–4500 ft ( 0–1372 m) Natural Gas Propane Model drill size drill size Aries 33 / Aries CD 33 #51 (0.067”)* #61 (0.039”)* Aries 35 / Aries CD 35 #49 (0.073”)* #58 (0.042”)* Aries 40 / Aries CD 40 #48 (0.076”)*...
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Table 7: Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall...
  • Page 14: Minimum Clearances To Combustibles

    Top Vent with one 90° Elbow Model Secure Vent Secure Flex (flex elbow) ® ® Aries 33 / Aries CD 33 44” (1118 mm) 46” (1168 mm) Aries 35 / Aries CD 35 47” (1194 mm) 49” (1245 mm) No combustibles Aries 40 / Aries CD 40 52”...
  • Page 15: Wall Finishes / Surrounds / Mantels

    Secure Flex (flex elbow) ® ® top of fireplace and/or vent pipe, whichever is higher Aries 33 / Aries CD 33 34” (864 mm) 34” (864 mm) Aries 35 / Aries CD 35 35 1/2” (902 mm) 35 1/2” (902 mm) Aries 40 / Aries CD 40 40 1/2”...
  • Page 16: Installation Sequence

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions.
  • Page 17 Front View Left Side View Right Side View Model H (door) Aries 33 / Aries CD 33 30 1/8 (765) 26 1/4 (667) 18 5/16 (465) 30 1/2 (775) 33 5/8 (854) 21 7/8 (556) 10 15/16 (278) 31 (787)
  • Page 18: Route The Gas Supply Line To The Fireplace

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 8).
  • Page 19 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Rough in the Electrical Supply, if Needed 1. As necessary, rough in the fireplace electrical supply per NEC and local codes. Install the [Optional] Blower Kit before Installation in the Framing 1.
  • Page 20 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 If you require a rear vent unit, check to see if rear venting has a vent cap and insulation in place. If so, remove cap and any insulation in vent pipes, make sure flue is open completely to firebox inside. Once flue pipe has clear passages on inner and outer pipes, proceed with vent connections.
  • Page 21 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. 2. If necessary, assemble the vent restrictor and wing as detailed in Figure 12 and Figure 15.
  • Page 22 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required.
  • Page 23 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Vent section length table Table 15 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1 1/2” shorter.
  • Page 24: Install The Vent System

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (25 mm) from all sides NOTE: Attic insulation shield (H3907) must be installed when blown or loose-fill insulation is used, and is recommended for all attic installations.
  • Page 25 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Page 22 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 26 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 8. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 22 for more information.
  • Page 27 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 28 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Table 18: Top Vent—Two 90° Elbows Table 19: Rear Vent—Three Elbows Table 20: Top Vent—Three Elbows When using Secure Flex , use ® Ceiling ceiling firestop/ firestop/spacer spacer SF4.5VF.
  • Page 29 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 30 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 9. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 31 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Figure 27: Installing the Horizontal Termination To help minimize water infiltration it is recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior Termination side of the wall. 7”...
  • Page 32 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Table 21: Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6–9 1/4” (152–235 mm) Termination Kit and 6” Vent Section (SV4.5L6) 10 3/4–14”...
  • Page 33 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Table 24: Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 7.62 1.524 Ceiling firestop/ Install the U-shaped vent restrictor in any vent run with more than 4 ft of vertical rise.
  • Page 34 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Table 27: Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum Wall firestop/spacer SV4.5HF ** feet meters feet meters feet meters 1.524 0.610 0.305 3.048 1.219 0.610...
  • Page 35 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Vertical or Horizontal Venting Using Secure Flex Kits and Components When Secure Flex kits are used in a rear flue, horizontal termination installation, at least 1 ft of vertical rise is required.
  • Page 36: Complete The Field Wiring

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 d. Slide the outer flexible vent over the adaptor collar. Ensure the flexible vent completely engages the adaptor collar 1 3/4” from the end, and that it is free from damage or tears.
  • Page 37 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Figure 31: Wiring Diagram—Millivolt Gas Valves Figure 32: Wiring Diagram—Electronic Gas Valves THERMOPILE APPLIANCE- MOUNTED ON/OFF SWITCH (OPTIONAL) TP-TH JUNCTION BOX AC/DC 120V AC POWER ELECTRONIC PILOT ASSEMBLY ADAPTOR...
  • Page 38: Install The [Optional] Blower Kit After Installation In The Framing

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 8. After the wiring is complete, replace the cover plate. WARNING Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in connecting the electronic components to the junction box in the lower compartment.
  • Page 39: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Figure 34: Control Compartment Figure 35: Gas Line Connection 3/8 NPT x 3/8” 1/2 x 3/8” Flare Flare fitting shutoff valve valve 3/8” Flex tubing (Optional) flexible gas line connector stub 1/2 x 3/8”...
  • Page 40: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Electronic Fireplace Inspection To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame should engulf the flame rod (Figure 37).
  • Page 41 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Air Shutter Adjustment Guidelines • If smoke or soot is present, first check the log set positioning to ensure that the flames are not impinging on any of the logs. If the log set is properly positioned and a sooting condition persists, then the air shutter should be opened more.
  • Page 42: Install The Hood

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Install the Hood NOTE: All models must have a hood installed prior to operation. 1. Install the hood by sliding it into the slots on the lower edge of the cabinet top.
  • Page 43: Attach The Safety-In-Operation Warnings

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 44: Installation Accessories

    Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 INSTALLATION ACCESSORIES Table 31: Listed Secure Vent Components ® Catalog Catalog Model Description Model Description Number Number Rigid, Horizontal, Compact Termination with Firestop/Spacer F1797 SV4.5HTKCT (H2246), Adaptor (74L61) (see 750204M)
  • Page 45 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Table 31: Listed Secure Vent Components ® 77L76 SV4.5E45 45° Elbow Termination Shroud (Guard) for H5820 SV4.5HTSK Horizontal Square Termination (1 pack) (see 750246M) 77L77 SV4.5E90 90° Elbow Catalog...
  • Page 46: Gas Conversion Kits

    Table 33: Millivolt Systems,Natural Gas To Propane Gas Conversion Kits Table 34: Millivolt Systems, Propane Gas to Natural Gas Conversion Kits Models Catalog Number Models Catalog Number Aries 33 / Aries CD 33 F1893 Aries 33 / Aries CD 33 F1891 Aries 35 / Aries CD 35 F1771...
  • Page 47 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Installing Gas Conversion Kits WARNING The gas supply shall be shut OFF prior to disconnecting the electrical power, before proceeding with the conversion. AVERTISSEMENT Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez l’alimentation electrique.
  • Page 48 Innovative Hearth Products Installation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Figure 43: Millivolt Pilot Figure 44: Orifice Pilot Pilot Orifice Orifice 12. Use pipe joint compound or Teflon tape on all pipe fittings before installing. ® NOTE: Ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds on flare fittings.
  • Page 49: Operation

    Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 50 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 51 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 52 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 NOTE: Do NOT wire more than one valve to the burner control switch. This will help prevent excessive resistance in the burner circuit, that can cause burner operation problems.
  • Page 53 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Installing the logs, volcanic stone, and glowing embers WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. • Do NOT install the logs until the appliance has been competely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 54 Follow the log placement instructions precisely. NOTE: Do not cover the burner ports. NOTE: Ensure the left front log (1) and right front log (2) are correctly installed on the burner positioning pins. Table 37: Aries 33 and 35 Log Set Log Number Description...
  • Page 55 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Installing the Aries 40 and Aries 45 logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 56 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 57 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located.
  • Page 58: Maintenance

    Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 MAINTENANCE Refer to the Maintenance Schedule on Page 61 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing.
  • Page 59 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 60 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Glass Media Removing and cleaning the glass media CAUTION Risk of personal injury. Allow the media to completely cool before handling. Use a clean, dry, empty shop vac to remove glass media. Wash the media in warm, soapy water. Rinse and dry before reinstalling.
  • Page 61 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 39: Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure...
  • Page 62: Accessory Components

    Bag of Glass Media, Reflective Black Brickaded Firebox Liner Kits Table 45: Brickaded Firebox Liner Kits Catalog Model Description Used on F1887 MBLK33B Buff Aries 33 / Aries CD 33 F1886 ABLK33V Vintage Red F1827 MBLK35B Buff Aries 35 / Aries CD 35 F1825 ABLK35V...
  • Page 63 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Thermostatic Control Kits Feature a thermostatic ON/OFF mode as well as manual ON/OFF operation. Table 47: Thermostatic Control Kits RC-S-STAT, Thermostatic or manual operation Catalog Number • LCD display •...
  • Page 64 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Unit-Mountable Rocker Switch Kit This rocker switch kit can be installed directly in the control compartment to provide ON/OFF operation in lieu of a wall switch. Table 49: Unit-Mountable Rocker Switch...
  • Page 65: Lighting Instructions

    Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 LIGHTING INSTRUCTIONS Millivolt Gas Valve FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 66 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 67 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Electronic Gas Valve FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 68 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 69: Troubleshooting

    Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 70 Innovative Hearth Products Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Table 53: Troubleshooting Electronic Systems 1. Nothing happens a. Remote is not functioning properly. Check that the wall switch plate is set to REMOTE. when the fireplace is Operate the fireplace from the wall plate switch.
  • Page 71: Replacement Parts

    Operation Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 REPLACEMENT PARTS Table 54: Installer Replacement Parts Aries 33 / Aries CD 33 Aries 35 / Aries CD 35 Aries 40 / Aries CD 40 Aries 45 / Aries CD 45 Description...
  • Page 72 WARNING Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. Table 55: Homeowner Replacement Parts Aries 33 / Aries CD 33 Aries 35 / Aries CD 35 Aries 40 / Aries CD 40...
  • Page 73: Warranty

    THE WARRANTY Innovative Hearth Products (“IHP”) Limited Lifetime Warranty warrants your Astria™ brand gas fireplace (“Product”) to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 74 Innovative Hearth Products Installation and Operation Instructions Astria™ Aries Direct-Vent Gas Fireplaces 900004-01, 04/2015 Contact an IHP dealer to obtain parts. Please contact IHP for the phone number of your nearest IHP dealer. Astria.US.com Record the following important information about your fireplace:...

This manual is also suitable for:

Aries 35Aries 40Aries 45

Table of Contents