Rear Panel - Lab.gruppen PLM 20K44 Operation Manual

Plm+ series powered loudspeaker management system
Hide thumbs Also See for PLM 20K44:
Table of Contents

Advertisement

4. Product Overview

4.2. Rear panel

CH 1
CH 2
Ser. N:o
Removed!
1+/- CH 1+/-
CLASS 3
2+/- CH 2+/-
1+:+
WIRING
BRIDGE CH 1 & 2:
2- : -
The PLM+ is available with a choice of connectors for power outputs: binding posts or Neutrik speakON®. Both
connection methods allow for Bridge Mode operation, which is activated from the Lake Controller software. Please
refer to the Lake Controller Operation Manual and section 8.1.1 of this Operation Manual for further information on
Bridge Mode.
Binding Posts – In this version, the power outputs for loudspeaker connection are available on four separate
1
pairs of fully enclosed binding posts. Bridge Mode can be enabled via the Lake Controller software; please refer to
the Lake Controller Operation Manual for further information.
speakON Connectors – The power outputs are simultaneously available on a single 8-pole speakON
2
connector, and on two 4-pole speakON connectors. The two 4-pole connectors carry the outputs of channels 1
& 2 and 3 & 4 respectively. Bridge Mode can be enabled via the Lake Controller software. Please refer to the Lake
Controller Operation Manual.
Analog Inputs – Analog inputs are available on four standard XLR3F latching connectors. The inputs are
3
electronically balanced and feature Lake Iso-Float circuitry. The impedance is 20 kohms, and the inputs can accept
a maximum input level of +26 dBu.
AES3 Inputs – Two latching XLR3F connectors are provided for AES3 digital audio signals (four audio
4
channels). Input impedance is 110 ohms, please ensure that 110 ohm digital audio cables are used; standard XLR
microphone cables are rarely suitable for reliable digital audio transmission.
Note: The PLM+ does not provide Analog or AES loop through / Link connectors. Where needed,
it is recomended to use Y-split cables or patchpanels wired to connect the Inputs with Link output
connectors. The AES3 termination load shall be enabled when the PLM+ is the last unit connected
within an AES3 daisy-chained system. The termination may be disabled, if desired, via the front panel
menu and within the Lake Controller software.
14
PLM+ SERIES Operation Manual rev 1.0.0
1
SPEAKER OUTPUTS
INPUT 1
INPUT 2
CH 3
CH 4
ANALOG WITH
CLASS 3 WIRING
SPEAKER OUTPUTS
INPUT 1
INPUT 2
2
ANALOG WITH
1+/- CH 3+/-
1+/- CH 1+/-
3+/- CH 3+/-
2+/- CH 4+/-
2+/- CH 2+/-
4+/- CH 4+/-
BRIDGE CH 3 & 4: 1+ : +, 2- : -
3
4
INPUT 1-2
INPUT 3-4
1Gbps
INPUT 3
INPUT 4
PIN 1: SCRN 2: POS 3: NEG
I
F
SO-
LOAT
TM
AES/EBU
INPUT 1-2
INPUT 3-4
1Gbps
INPUT 3
INPUT 4
PIN 1: SCRN 2: POS 3: NEG
I
F
AES/EBU
SO-
LOAT
TM
5
6
PRIM
ACT
1Gbps
SEC
ACT
100-240V
2400-2950W
50-60Hz
LINK
LINK
PLM 2K44
1
SWITCHED 00/ 000 Base-TX
1
1
Made in Sweden
Must be grounded/earthed
PRIM
ACT
1Gbps
SEC
ACT
100-240V
2400-2950W
50-60Hz
LINK
LINK
PLM 2K44
1
SWITCHED 00/ 000 Base-TX
1
1
Made in Sweden
Must be grounded/earthed