7. Front Panel Interface
7.11.5.1. Frame Info
MENU > FRAME > FRAME INFO
Frame Info provides information about the device settings and configuration. All data in this front panel menu is
read-only; some parameters are fixed, and some can be changed only via the Lake Controller software.
Firmware Version (FW Version)
The firmware version numbers are displayed on left side of screen. This information can be used to verify that the
latest firmware is installed and is useful if a technical issue arises.
Further internal version numbers are displayed on right side of screen; Bundle, DSP, FPGA and Safe Image version.
Serial Number (Serial No.)
The printed serial number on the back panel of the PLM+ is also electronically embedded in the hardware, and
therefore cannot be removed or altered if stolen.
Max Output Voltage (MaxOutVolt)
Displays the maximum output voltage per channel that can exist across the PLM+'s output terminals. This is the
absolute maximum, not the voltage defined by the ISVPL setting.
Note: When Bridge Mode is activated, double the channel output voltage is available.
Max Output Current (MaxOutCurr)
Displays the maximum output current that can be delivered by the PLM+, summed across all output channels.
7.11.5.2. Frame Reset and Configuration
MENU > FRAME > RESET
Use this option to display a further menu with options to reset all parameters back to their original factory default
values. See section 9.3 for a full list of the default factory reset parameter values. Two types of reset are provided:
Factory Reset and Soft Reset.
Factory Reset
A Factory Reset will reset all settings and parameters to the original factory-defined default values. This includes
the deletion of any Frame Presets stored within the device. It also resets the IP Address and all network related
settings including the Dual Redundancy setting; a hard power cycle is required to complete this reset.
Soft Reset
A Soft Reset will reset all settings and parameters to the original factory-defined default values, but retains Frame
Preset information and IP / Network configuration. A power cycle is not required to complete this type of reset.