Table 9.4: Glossary of Terms, Acronyms and Abbreviations
A device on an Ethernet network which is not communicating with the rest of the network either due to a fault or intentionally is said to be offline.
A device on an Ethernet network which is fully operational and communicating with the rest of the network is said to be online.
An abbreviation for Power Average Limiter, PAL is proprietary Lab.gruppen circuit which provides additional amplifier protection. The PAL ensures that the power
drawn by the PSU from the AC mains does not exceed the mains breaker ratings.
Two or more e.g. inputs which are wired together so that all inputs are connected to the same source are said to be paralleled. Signal levels will be reduced if too
many inputs are paralleled; in the case of AES3, this may result in a complete loss of audio.
Any control function which can be adjusted by the user to one of several different values is termed a parameter. For example, input level, gain, delay, and limiter
Power Factor Correction. PFC reduces current peaks on the lines and reduces the requirements placed on the mains distribution system.
Ping is a term coined by the IT industry to the procedure of sending a command over a network to a particular Ethernet device asking it to confirm its identity and
possibly reply with additional information. Thus an Lake device on the network can be pinged from the Lake Controller; on receipt of the 'ping', the hi-intensity
white LED on the front panel illuminates. Reverse pinging is also possible, whereby the ping is instigated from Lake hardware device and a visual identification of
the processor registers in the Lake Controller software.
A complete frame configuration that is stored in the device hardware.
The Primary Ethernet port on the is the means of connecting the device to a network. See also Secondary Ethernet Port.
Abbreviation of Power Supply Unit. The PSU in any item of electronic equipment converts the AC mains into a set of internal DC voltages which run the electronic
RJ45 connections are the industry-standard connectors for Ethernet ports.
As far as networks of the type discussed in this manual are concerned, see Switch.
The Secondary Ethernet port can be used either as a daisy-chain output, repeating the network connection at the Primary port, or for the connection of a separate
A Lab.gruppen proprietary protective circuit designed to mute a channel when a short circuit is detected at its output terminals to prevent damage to the device.
Once activated, SpeakerSafe constantly monitors the voltage and current at the PLM+'s outputs. Using Fingerprint data, the software then calculates parameters
such as voice coil and magnet temperatures, providing the operator with real-time performance monitoring. See LoadLibrary.
An industrial-quality loudspeaker connector manufactured by Neutrik. 4-pole (2 speakers) and 8-pole (4 speakers) versions are fitted to various versions of the PLM+.
A network topology which uses a network switch to connect to individual Lake devices. Each device connects to one port on the switch with its own cable, thus the
network looks like a star when drawn as a diagram with the switch at the centre.
A Cat-5/6 network cable with full pin-to-pin connections is called a straight network cable. Lake devices can connect to a network using either straight or crossed
It is possible when working with large networked systems to store selected components of the system into a Subsystem. This is useful if working on a tour that
encompasses both large and mid-sized venues. The same core Lake Controller data can then be used for a reduced number of Lake devices.
A Super Module is a virtual construct that can be realized within the Lake Controller, allowing a set of Modules in different Frames to be treated as a single Module.
An Ethernet switch allows several Ethernet devices to be connected to a network using a star topology. More intelligent than the earlier hubs which they now largely
replace, they route packets of data only to the units for which they are intended, and also perform other system housekeeping and control functions.
A class of Preset within the Lake Processing system, System Presets allow Module or Frame configurations and settings to be stored for the entire network of
LM 26 Processors, PLM Series, PLM+ Series and other legacy Lake devices.
A compact PC which uses a touchscreen instead of keyboard and mouse. The Lake Controller has been optimized for use on Tablet PCs.
AES3 digital audio interconnections must be correctly terminated for reliable operation. The 110 ohm terminations must be set 'on' at the beginning and end of a
set of daisy-chained digital audio equipment, and 'off' at any intermediate ones.
A mathematical word for "arrangement" or "configuration". The topology of a network is a means of visualizing the overall configuration of the network.
A power supply that operates in all countries, without the need for manual adjustment, as long as the voltage falls within the specified range for the device.
VHF protection is another amplifier safety circuit developed by Lab.gruppen. The presence of continuous HF audio can easily damage loudspeakers, so the
protection circuit monitors the output this, muting the power output channel if necessary
Indicates the peak voltage of an audio signal. For a sinusoidal signal, the peak voltage = 1.414 x the RMS voltage, Vrms. Not to be confused with peak-to-peak
A device used to connect a computer to an Ethernet network without cables; a radio transmitter/receiver for data.
An Ethernet network where some or all cabled connections are replaced by wireless links.
Description
threshold are all parameters.
See Straight network cable.
assemblies themselves.
second network for full redundancy.
network cables.
voltage (written V pk-pk), which = V peak x 2.
The RMS voltage of a signal. See RMS.
PLM+ SERIES Operation Manual rev 1.0.0